3.2.3 Initialization
When a Management Client is initialized:
The Management Client Name field is constructed in an implementation-specific manner. This name object MUST be used when initializing the underlying OleTx Transports Protocol implementation as the Local Name Object (as specified in [MS-CMPO] section 3.2.3). The initialization process of the underlying OleTx Transports Protocol is specified in section 2.1.2.
The Management Server Name is constructed by initializing the fields of the Name object (specified in [MS-CMPO] section 3.2.1.4) with the following values:
HostName: The HostName field is initialized with the value of the ComputerName.NetBIOS element of the machine as specified in [MS-WKST] section 3.2.1.2.
CID: The CID field is initialized as follows:
Read the string value, using the Windows Remote Registry Protocol [MS-RRP], from the "HKEY_CLASSES_ROOT\CID\<MSDTCUIS_GUID>" registry key as specified in section 2.2.3.5, for the Description\Default value of "MSDTCUIS" as specified in section 2.2.3.5.1.
Convert the <MSDTCUIS_GUID> string to a GUID as specified in [C706] Appendix A.
Protocols:
The Management Connection field MUST be assigned a null value.
The Management Server Cluster Resource ID field MUST be assigned a null value.