Get Energy Source Thresholds (Function Index 7)
This _DSM Interface for Byte Addressable Energy Backed Function Class (Function Interface 1) function returns warning and error thresholds that indicate a problem with the Energy Source (ES) if they hit or surpassed. This function may return a failure status if the ES is host-managed and the platform doesn't support thresholds.
Registers are defined in the Byte Addressable Energy Backed Interface specification.
Input
Arg3
None.
Output
Field | Byte length | Byte offset | Register | Description |
---|---|---|---|---|
Status | 4 | 0 | See _DSM Method Output. | |
ES Lifetime Percentage Warning Threshold | 1 | 4 | Byte 0: ES_LIFETIME_WARNING_THRESHOLD (0, 0x99) | The percentage value of the warning threshold for the ES lifetime. |
ES Lifetime Percentage Error Threshold | 1 | 5 | Byte 0: ES_LIFETIME_ERROR_THRESHOLD (0, 0x91) | The percentage value of the error threshold for the ES lifetime. |
ES Temperature Warning Threshold | 1 | 6 | Byte 0: ES_TEMP_WARNING_THRESHOLD (0, 0x9A) | The percentage value of the warning threshold for the ES temperature. |
ES Temperature Error Threshold | 1 | 7 | Byte 0: ES_TEMP_ERROR_THRESHOLD (0, 0x92) | The percentage value of the error threshold for the ES temperature. |
Related articles
Set Energy Source Lifetime Warning Threshold (Function Index 8)
Set Energy Source Temperature Warning Threshold (Function Index 9)