Get Energy Source Health Info (Function Index 12)

This _DSM Interface for Byte Addressable Energy Backed Function Class (Function Interface 1) function returns information about the health of the Energy Source (ES) module. This function may return a failure status if the ES is host-managed and health information isn't available.

Registers are defined in the Byte Addressable Energy Backed Interface specification.

Input

Arg3

None.

Output

Field Byte length Byte offset Register Description
Status 4 0 This function can return the following Function-Specific Error Code: 1. The platform does not support ES health information. For more information, see _DSM Method Output.
ES Lifetime Percentage 1 4 Byte 0: ES_LIFETIME (1, 0x70) The last known ES lifetime percentage.
ES Current Temperature 2 5 Byte 0: ES_TEMP0 (1, 0x71); Byte 1: ES_TEMP1 (1, 0x72) The ES temperature in degrees Celsius. The minimum value is 0.
Total Runtime 4 7 Byte 0: ES_RUNTIME0 (1, 0x73); Byte 1: ES_RUNTIME1 (1, 0x74); Bytes 2-3: Reserved The time (in hours) the ES has been operational since it was manufactured.

Get NVDIMM-N Health Info (Function Index 11)

Get Energy Source Health Info (Function Index 12)