Muokkaa

Jaa


How to use IotJsonPathContent templates with the MedTech service device mapping

This article provides an overview of how to use IotJsonPathContent templates within a MedTech service device mapping.

IotJsonPathContent template basics

IotJsonPathContent templates can be used when the MedTech service ingests device messages routed from an Azure IoT Hub. When IotJsonPathContent templates are used within the device mapping, the MedTech service extracts the device ID and measurement timestamp from metadata provided by an IoT hub. The DeviceIdExpression and TimestampExpression shouldn't be included in IotJsonPathContent templates.

The MedTech service IotJsonPathContent templates support the JSON expression language JSONPath. Expressions are used to identify which template to use with a given JSON device message (for example: TypeMatchExpression) and to extract specific values that are required to create a normalized message (for example: PatientIdExpression, ValueExpression, etc.). IotJsonPathContent templates are similar to the CalculatedContent templates except the DeviceIdExpression and TimestampExpression aren't supported.

Note

JMESPath is not supported by IotJsonPathContent templates.

An expression is defined as:

<name of expression> : <the expression>

In the following example, typeMatchExpression is defined as:

"templateType": "IotJsonPathContent",
"template": {
   "typeName": "heartrate",
   "typeMatchExpression": "$..[?(@heartRate)]",
...
}

If your MedTech service is set up to ingest device messages from an IoT hub, you aren't required to use IotJsonPathContent templates. CalculatedContent templates can be used assuming that you correctly define the DeviceIdExpression and TimestampExpression.

The IotJsonPathContent templates allow matching on and extracting values from a device message read from an Azure Event Hubs event hub through the following expressions:

Element Description JSONPath expression example
typeMatchExpression The expression that the MedTech service evaluates against the device message payload. If the service finds a matching token value, it considers the template a match. $..[?(@heartRate)]
patientIdExpression The expression to extract the patient identifier. Required when the MedTech services's Resolution type is set to Create, and optional when the MedTech service's Resolution type is set to Lookup. $.SystemProperties.iothub-connection-device-id
encounterIdExpression Optional: The expression to extract the encounter identifier. $.Body.encounterId
correlationIdExpression Optional: The expression to extract the correlation identifier. You can use this output to group values into a single observation in the FHIR® destination mapping. $.Body.correlationId
values[].valueExpression The expression to extract the wanted value. $.Body.heartRate

Important

The MedTech service will use the device ID defined in IoT hub as the FHIR resource device identifier. If the MedTech service is set up to use an identity resolution type of Lookup, a Device resource with a matching device identifier must exist in the FHIR service or an error will occur when the device message is processed. If the MedTech service's identity resolution type is set to Create, a patientIdExpression must be included in the device mapping so that a new Patient resource and Device resource can be created if they do not already exist.

Note

The Resolution type specifies how the MedTech service associates device data with Device resources and Patient resources. The MedTech service reads Device and Patient resources from the FHIR service using device identifiers and patient identifiers. If an encounter identifier is specified and extracted from the device data payload, it's linked to the observation if an encounter exists on the FHIR service with that identifier. If the encounter identifier is successfully normalized, but no FHIR Encounter exists with that encounter identifier, a FhirResourceNotFound exception is thrown. For more information on configuring the MedTech service Resolution type, see Configure the Destination tab.

Expression languages

JSONPath is the default expression language, and inclusion of an expression language within an IotJsonPathContent template isn't supported. If you attempt to specify the expression language in an expression object, the IotJsonPathContent template containing the expression object fails.

"templateType": "IotJsonPathContent",
   "template": {
      "typeName": "heartrate",
      "typeMatchExpression": "$..[?(@heartRate)]",
...
}

Tip

For more information on JSONPath, see JSONPath - XPath for JSON. IotJsonPathContent templates use the JSON .NET implementation for resolving JSONPath expressions.

Example

When the MedTech service is processing a device message, the templates in the CollectionContent are used to evaluate the message. The typeMatchExpression is used to determine whether or not the template should be used to create a normalized message from the device message. If the typeMatchExpression evaluates to true, then the valueExpression value is used to locate and extract the JSON values from the device message and create a normalized message.

Tip

Visual Studio Code with the Azure IoT Hub extension is a recommended method for sending IoT device messages to your IoT hub for testing and troubleshooting.

You can use the MedTech service Mapping debugger for assistance creating, updating, and troubleshooting the MedTech service device and FHIR destination mappings. The Mapping debugger enables you to easily view and make inline adjustments in real-time, without ever having to leave the Azure portal. The Mapping debugger can also be used for uploading test device messages to see how they'll look after being processed into normalized messages and transformed into FHIR Observations.

In this example, we're using a device message that is capturing heartRate data:

{
    "PatientId": "patient1",
    "HeartRate" : "78"
}

Note

To avoid device spoofing in device-to-cloud (D2C) messages, Azure IoT Hub enriches all device messages with additional properties before routing them to the event hub. For example: Properties: iothub-creation-time-utc and SystemProperties: iothub-connection-device-id. For more information, see Anti-spoofing properties.

patientIdExpression is only required for MedTech services in the Create mode; however, if Lookup is being used, a Device resource with a matching device identifier must exist in the destination FHIR service. These examples assume your MedTech service is in the Create mode. For more information on the Create and Lookup Destination properties, see Configure the Destination tab.

The IoT hub enriches and routes the device message to the event hub before the MedTech service reads the device message from the event hub:

{
    "Body": {
        "PatientId": "patient1",
        "HeartRate": "78"
    },
    "SystemProperties": {
        "iothub-enqueuedtime": "2023-07-25T20:41:26.046Z",
        "iothub-connection-device-id": "sampleDeviceId"
    },
    "Properties": {
        "iothub-creation-time-utc": "2023-07-25T20:41:26.046Z"
    }
}   

We're using this device mapping for the normalization stage:

{
    "templateType": "CollectionContent",
    "template": [
        {
            "templateType": "IotJsonPathContent",
            "template": {
                "typeName": "HeartRate",
                "typeMatchExpression": "$..[?(@Body.HeartRate)]",
                "patientIdExpression": "$.Body.PatientId",
                "values": [
                    {
                        "required": true,
                        "valueExpression": "$.Body.HeartRate",
                        "valueName": "HeartRate"
                    }
                ]
            }
        }
    ]    
}

The resulting normalized message will look like this after the normalization stage:

{
    "type": "HeartRate",
    "occurrenceTimeUtc": "2023-07-25T20:41:26.046Z",
    "deviceId": "sampleDeviceId",
    "patientId": "patient1",
    "properties": [
        {
            "name": "HeartRate",
            "value": "78"
        }
    ]
}

Tip

For assistance fixing common MedTech service deployment errors, see Troubleshoot MedTech service deployment errors.

For assistance fixing MedTech service errors, see Troubleshoot errors using the MedTech service logs.

Next steps

Receive device messages through Azure IoT Hub

Overview of the FHIR destination mapping

Overview of the MedTech service scenario-based mappings samples

Note

FHIR® is a registered trademark of HL7 and is used with the permission of HL7.