Modern Standby Wake on Voice Basic Test on DC-power Source
Wake on Voice (Keyword) Basic Test implements two test cases: - one test case exercises the DC-power source - the other test case exercises the AC-power source. Software-simulated battery is used to change power sources. The test causes the system to enter and exit Modern Standby. Some system measurements are also taken to validation during the tests such as Modern Standby support, Software and Hardware DRIPS (Deepest Runtime Idle Power State), lower Divergence Delta between the Software DRIPS and the hardware DRIPS, Hardware Keyword spotting support, reasonable Modern Standby Exit Latency. NOTE: On Modern Standby system where the storage device containing the boot volume is not backed by a physical disk of Solid State Disk (SSD) media type or Storage Class Memory (SCM) media type, the Modern Standby Exit Latency is reported but the constraints on the measured latency value will not be enforced by this Modern Standby Basic Requirement Test.In the case where the storage device/solution reports a seek penalty or a rotational delay (thus indicating rotating media), the Modern Standby system will operate in a default Disconnected Mode.
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 30 |
Category | Development |
Timeout (in minutes) | 60 |
Requires reboot | false |
Requires special configuration | false |
Type | manual |
More Information
Parameters
Parameter Name | Parameter Description |
---|---|
TestCycles | Number of test cycles |
DelayBetweenCycles | Delay time in milliseconds between each test cycle |
DelayAfterPowerSourceChange | Delay time in milliseconds after each power source change |
ModernStandbyDuration | Modern Standby duration in milliseconds |
ModernStandbyExitLatencyThreshold | Modern Standby Exit Latency threshold in milliseconds. |
ModernStandbySDripsThreshold | The Modern Standby Software DRIPS threshold time in [%]. |
ModernStandbyHDripsSDripsDelta | The acceptable divergence delta of percentage [%] between the Software DRIPS measured in [%] and the Hardware DRIPS measured in [%]. |
ModernStandbyDisconnectedModeFlag | An optional Disconnected Mode test flag. |
TestTimeoutValue | Timeout value for the execution of te.exe |
OptTeCmdlineParams | Optional command-line parameters for te.exe |
Additional Documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.