USB Device Connection S3+S4+Connected Standby

This test verifies that a USB-based device becomes available within 500 milliseconds after the test system exits the S3 or S4 power state or connected standby. The test also confirms that there were not any errant device disconnects during system resume.

Test details

   
Specifications
  • Device.Connectivity.UsbDevices.DeviceAttachLessThan100ms
  • Device.Connectivity.UsbDevices.MustBeFunctionalAfterResume
  • Device.Connectivity.UsbDevices.MustResumeWithoutForcedReset
  • Device.Connectivity.UsbDevices.MustSignalAttachWithin500ms
Platforms
  • Windows 10, client editions (x86)
  • Windows 10, client editions (x64)
  • Windows Server 2016 (x64)
Supported Releases
  • Windows 10
  • Windows 10, version 1511
  • Windows 10, version 1607
  • Windows 10, version 1703
  • Windows 10, version 1709
  • Windows 10, version 1803
  • Windows 10, version 1809
  • Windows 10, version 1903
  • Next update to Windows 10
Expected run time (in minutes) 10
Category Compatibility
Timeout (in minutes) 15
Requires reboot false
Requires special configuration false
Type automatic

 

Additional documentation

Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):

More information

Parameters

Parameter name Parameter description
WDKDeviceID Device ID of the device under test
queryIsUsb3 QueryIsUsb3 of device under test
DFUDevice Uses DFU to reflash firmware on connect

 

Troubleshooting

For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.