Windows Hid Validation Test
This test verifies that Windows® Touch device firmware is human interface device (HID)-compliant and doesn't require additional driver installation.
Test details
Associated requirements |
Device.Digitizer.Touch.DigitizerJitter Device.Digitizer.Touch.HIDCompliantFirmware |
Platforms |
Windows RT (ARM-based) Windows 8 (x64) Windows 8 (x86) Windows RT 8.1 Windows 8.1 x64 Windows 8.1 x86 |
Expected run time |
~4 minutes |
Categories |
Certification |
Type |
Manual |
Running the test
Before you run the test, complete the test setup as described in the test requirements: Windows Touch Testing Prerequisites.
Troubleshooting
For troubleshooting information, see Troubleshooting Device.Digitizer Testing.
More information
HIDvalidator.exe checks your HID descriptor to ensure compliance with the HID specification. It ensures that all necessary usages are present, and catches invalid values. Thirty-four rules are validated. This tool produces an easy-to-read report.
Rules
Rule 1: Touch-screen devices must support multiple touches.
Rule 2: Device must support at least 5 contacts.
Rule 3: Device must use parallel or hybrid packet reporting mode or single-finger hybrid reporting mode. When the device is connected through I2C, “single-finger hybrid” is required.
Rule 4: A usage item tag must be associated with any collection (such as a pen, touch screen, or finger).
Rule 5: The report descriptors for the touch device should use the finger (0x22) CL (Collection Logical) to group the data and control usages in the top-level collections.
Rule 6: Device must report generic X and generic Y.
Rule 7: The logical minimum and the logical maximum of the generic X must be specified correctly.
Rule 8: The logical minimum and the logical maximum of the generic Y location must be specified correctly.
Rule 9: The physical minimum and the physical maximum of the generic X location must be specified correctly.
Rule 10: The physical minimum and the physical maximum of the generic Y location must be specified correctly.
Rule 11: The minimum physical size of a digitizer must be at least 1 square inch (1 inch for generic X).
Rule 12: The minimum physical size of a digitizer must be at least 1 square inch (1 inch for generic Y).
Rule 13: The unit for the physical size of generic X must be inch or centimeter.
Rule 14: The unit for the physical size of generic Y must be inch or centimeter.
Rule 15: If the device supports z-axis detection, in-range must be supported as well.
Rule 16: Device that support the center value must also support the width and height usages. Devices should have a usage array of two X values and two Y values to report T and C.
Rule 17: Device must report “tip” switch.
Rule 18: Device must report scan time in the top-level collection, must have a minimum report length of 16 bits, must be less than or equal to 0x7fffffff, and must be at least 65,535.
Rule 19: Device must report actual count usage correctly in the top-level collection.
Rule 20: Device must support the contact identifier usage to specify the identifier of the current contact.
Rule 21: Device must implement the maximum count usage correctly in the top-level collection as a feature report, and not in any child collection.
Rule 22: The contact count maximum for a device must not exceed 250.
Rule 23: Device must implement the firmware key usage correctly with a length of 256 bytes on the user-defined usage page and in the top-level collection as a feature report.
Rule 24: The device configuration feature report must be in its own top-level collection and must include the multiple input configuration usages.
Rule 25: A logical range must be provided for all usages.
Rule 26: Supporting usages that belong to the usage page digitizer should be assigned to the digitizer (0x0D).
Rule 27: Supporting usages that belong to the usage page generic desktop should be assigned to the generic desktop (0x01).
Rule 28: All usages that are associated with the generic desktop usage page should be recognized.
Rule 29: All usages that are associated with the digitizer usage page should be recognized.
Rule 30: Usage should not be defined as 0 for any usage pages.
Rule 31: The physical range of the azimuth must be 0 to 360 degrees. The logical range must be large enough to deliver data that's accurate to at least 2 decimal places.
Rule 32: The units exponent of the azimuth usage must be accurate to at least 2 decimal places in degree, or it must be accurate to at least 4 decimal places in radians.
Rule 33: The units of the azimuth usage must be in degrees or radians.
Rule 34: The number of collections and end collections must match in the descriptor file. (Not available for real time.)