共用方式為


How to Configure Mobile Device Client Agent Settings

Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2

You configure the Mobile Device Client Agent settings, in Microsoft System Center Configuration Manager 2007, by modifying the site control file.

To configure the Mobile Device Client Agent settings

  1. Set up a connection to the SMS Provider.

  2. Make a connection to the Device Client section of the site control file by using the SMS_SCI_ClientComp class.

  3. Loop through the array of available properties, making changes as needed.

  4. Commit the property changes to the site control file.

Example

The following example method configures various Mobile Device Client Agent settings by using the SMS_SCI_ClientComp class to connect to the site control file and change properties.

For information about calling the sample code, see Calling Configuration Manager Code Snippets.

Sub ConfigureMobileDeviceClientAgentSettings(swbemServices,                        _
                                             swbemContext,                         _
                                             siteCode,                             _
                                             newPollIntervalMinutes,               _
                                             newPollIntervalHours,                 _
                                             newFailureRetryCount,                 _
                                             newFailureRetryIntervalMinutes,       _ 
                                             newFailureRetryIntervalHours,         _
                                             newEnableDisableSoftwareDistribution)

    ' Variables to build poll interval string.
    ' Note: The sample code only passes in minutes and hours, so setting empty values to use.
    emptySeconds = "00"
    emptyDays = "00"
    emptyMonths = "00"
    emptyYears = "0000"

    ' Build newPollInterval string (the format must be "0000-00-00 00:00:00").
    newPollInterval = emptyYears & "-" & emptyMonths & "-" & emptyDays & " " & newPollIntervalHours & ":" & newPollIntervalMinutes & ":" & emptySeconds
    newFailureRetryInterval = emptyYears & "-" & emptyMonths & "-" & emptyDays & " " & newFailureRetryIntervalHours & ":" & newFailureRetryIntervalMinutes & ":" & emptySeconds

    ' Load site control file and get the client component section.
    swbemServices.ExecMethod "SMS_SiteControlFile.Filetype=1,Sitecode=""" & siteCode & """", "Refresh", , , swbemContext
          
    Query = "SELECT * FROM SMS_SCI_ClientComp " & _
    "WHERE ClientComponentName = 'Device Client' " & _
    "AND SiteCode = '" & siteCode & "'"          
            
    Set SCIComponentSet = swbemServices.ExecQuery(Query, ,wbemFlagForwardOnly Or wbemFlagReturnImmediately, swbemContext)
                       
    ' Only one instance is returned from the query.
    For Each SCIComponent In SCIComponentSet
    
        ' Loop through the array of embedded property instances.
        For Each vProperty In SCIComponent.Props
                  
            ' Setting: Poll Interval
            If vProperty.PropertyName = "Poll Interval" Then
                wscript.echo " "
                wscript.echo vProperty.PropertyName
                wscript.echo "Current value " &  vProperty.Value2               
                
                'Modify the value.
                vProperty.Value2 = newPollInterval
                wscript.echo "New value " & newPollInterval
            End If
            
            ' Setting: Failure Retry Count
            If vProperty.PropertyName = "Failure Retry Count" Then
                wscript.echo " "
                wscript.echo vProperty.PropertyName
                wscript.echo "Current value " &  vProperty.Value               
                
                ' Modify the value.
                vProperty.Value = newFailureRetryCount
                wscript.echo "New value " & newFailureRetryCount
            End If
            
            ' Setting: Failure Retry Interval
            If vProperty.PropertyName = "Failure Retry Interval" Then
                wscript.echo " "
                wscript.echo vProperty.PropertyName
                wscript.echo "Current value " &  vProperty.Value2               
                
                ' Modify the value.
                vProperty.Value2 = newFailureRetryInterval
                wscript.echo "New value " & newFailureRetryInterval
            End If
            
            ' Setting: Enable Software Dist
            If vProperty.PropertyName = "Enable Software Dist" Then
                wscript.echo " "
                wscript.echo vProperty.PropertyName
                wscript.echo "Current value " &  vProperty.Value2               
                
                ' Modify the value.
                vProperty.Value2 = newEnableDisableSoftwareDistribution
                wscript.echo "New value " & newEnableDisableSoftwareDistribution
            End If
               
        Next   

        ' Update the component in your copy of the site control file. Get the path
        ' to the updated object, which could be used later to retrieve the instance.
        Set SCICompPath = SCIComponent.Put_(wbemChangeFlagUpdateOnly, swbemContext)
        
    Next
                          
    ' Commit the change to the actual site control file.
    Set InParams = swbemServices.Get("SMS_SiteControlFile").Methods_("CommitSCF").InParameters.SpawnInstance_
    InParams.SiteCode = siteCode
    swbemServices.ExecMethod "SMS_SiteControlFile", "CommitSCF", InParams, , swbemContext
      
    ' Release the copy of the site control file.
    swbemServices.Get("SMS_SiteControlFile").ReleaseSessionHandle swbemContext.Item("SessionHandle").Value

End Sub
public void ConfigureMobileDeviceClientAgentSettings(WqlConnectionManager connection,
                                                     string siteCode,
                                                     string newPollIntervalMinutes,
                                                     string newPollIntervalHours,
                                                     string newFailureRetryCount,
                                                     string newFailureRetryIntervalMinutes,
                                                     string newFailureRetryIntervalHours,
                                                     bool newEnableDisableSoftwareDistribution)
{

    // Define variables to build poll interval string.
    // Note: The example code only passes in minutes and hours, so this sets empty values to use.
    string emptyDays = "00";
    string emptyMonths = "00";
    string emptyYears = "0000";
    string emptySeconds = "00";

    // Build newPollInterval and newFailureRetryInterval strings (the format must be "0000-00-00 00:00:00").
    string newPollInterval = emptyYears + "-" + emptyMonths + "-" + emptyDays + " " + newPollIntervalHours + ":" + newPollIntervalMinutes + ":" + emptySeconds;
    string newFailureRetryInterval = emptyYears + "-" + emptyMonths + "-" + emptyDays + " " + newFailureRetryIntervalHours + ":" + newFailureRetryIntervalMinutes + ":" + emptySeconds;

    try
    {
        IResultObject siteDefinition = connection.GetInstance(@"SMS_SCI_ClientComp.FileType=1,ItemType='Client Component',SiteCode='" + siteCode + "',ItemName='Device Client'");

        // Loop through the array of embedded properties.
        foreach (KeyValuePair<string, IResultObject> kvp in siteDefinition.EmbeddedProperties)
        {
            // Create temporary working copy of embedded properties.
            Dictionary<string, IResultObject> embeddedProperties = siteDefinition.EmbeddedProperties;

            // Setting: Poll Interval.
            if (kvp.Value.PropertyList["PropertyName"] == "Poll Interval")
            {
                Console.WriteLine();
                Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
                Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value2"].StringValue);

                // Change value using the newPollInterval value passed in. 
                embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value2"].StringValue = newPollInterval;
                Console.WriteLine("New value    : " + newPollInterval);
            }

            // Setting: Failure Retry Count.
            if (kvp.Value.PropertyList["PropertyName"] == "Failure Retry Count")
            {
                Console.WriteLine();
                Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
                Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue);

                // Change value using the newFailureRetryCount value passed in. 
                embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value"].StringValue = newFailureRetryCount;
                Console.WriteLine("New value    : " + newFailureRetryCount);
            }

            // Setting: Failure Retry Interval.
            if (kvp.Value.PropertyList["PropertyName"] == "Failure Retry Interval")
            {
                Console.WriteLine();
                Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
                Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value2"].StringValue);

                // Change value using the newFailureRetryInterval value passed in. 
                embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value2"].StringValue = newFailureRetryInterval;
                Console.WriteLine("New value    : " + newFailureRetryInterval);
            }

            // Setting: Enable Software Dist.
            if (kvp.Value.PropertyList["PropertyName"] == "Enable Software Dist")
            {
                Console.WriteLine();
                Console.WriteLine(kvp.Value.PropertyList["PropertyName"]);
                Console.WriteLine("Current value: " + embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value2"].StringValue);

                // Change value using the newEnableDisableSoftwareDistribution value passed in. 
                embeddedProperties[kvp.Value.PropertyList["PropertyName"]]["Value2"].BooleanValue = newEnableDisableSoftwareDistribution;
                Console.WriteLine("New value    : " + newEnableDisableSoftwareDistribution);
            }

            // Store the settings that have changed.
            siteDefinition.EmbeddedProperties = embeddedProperties;
        }

        // Save the settings. 
        siteDefinition.Put();

    }
    catch (SmsException ex)
    {
        Console.WriteLine("Failed. Error: " + ex.InnerException.Message);
        throw;
    }
}

The example method has the following parameters:

Parameter

Type

Description

Connection

  • Managed: WqlConnectionManager

  • VBScript: SWbemServices

A valid connection to the SMS Provider.

siteCode

  • Managed: String

  • VBScript: String

The site code.

newPollInterval

  • Managed: String

  • VBScript: String

The interval that the client tries to contact the server.

The format of the string must be:

Years-months-days hours:minutes:seconds

"0000-00-00 00:00:00"

newPollIntervalMinutes

  • Managed: String

  • VBScript: String

A value representing the minutes of the newPollInterval string.

newPollIntervalHours

  • Managed: String

  • VBScript: String

A value representing the hours of the newPollInterval string.

newFailureRetryCount

  • Managed: String

  • VBScript: String

A value representing the hours of the newPollInterval string.

newFailureRetryIntervalMinutes

  • Managed: String

  • VBScript: String

A value representing the minutes of the newFailureRetryInterval string.

newFailureRetryIntervalHours

  • Managed: String

  • VBScript: String

A value representing the hours of the newFailureInterval string.

newEnableDisableSoftwareDistribution

  • Managed: Boolean

  • VBScript: Boolean

A value that enables or disables software distribution.

Enabled = true

Disabled = false

Compiling the Code

This C# example requires:

Namespaces

System

System.Collections.Generic

System.Text

Microsoft.ConfigurationManagement.ManagementProvider

Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine

Assembly

adminui.wqlqueryengine

microsoft.configurationmanagement.managementprovider

Robust Programming

For more information about error handling, see About Configuration Manager Errors.

Security

For more information about securing Configuration Manager applications, see Securing Configuration Manager Applications.

See Also

Concepts

System Center Configuration Manager Software Development Kit
Configuration Manager Mobile Device Management
About Software Updates Setup and Configuration
About the Configuration Manager Site Control File
How to Read and Write to the Configuration Manager Site Control File by Using Managed Code
How to Read and Write to the Configuration Manager Site Control File by Using WMI
SMS_SCI_Component Server WMI Class