共用方式為


LoggingOptions.GetColumnFilter Method

Returns column filter for the specified event.

命名空間: Microsoft.SqlServer.Dts.Runtime
組件: Microsoft.SqlServer.ManagedDTS (in microsoft.sqlserver.manageddts.dll)

語法

'宣告
Public Sub GetColumnFilter ( _
    eventName As String, _
    ByRef columnFilter As DTSEventColumnFilter _
)
public void GetColumnFilter (
    string eventName,
    ref DTSEventColumnFilter columnFilter
)
public:
void GetColumnFilter (
    String^ eventName, 
    DTSEventColumnFilter% columnFilter
)
public void GetColumnFilter (
    String eventName, 
    /** @ref */ DTSEventColumnFilter columnFilter
)
JScript 不支援以傳址方式傳遞值類型的引數。

參數

  • eventName
    The name of the event whose columns you want to control.
  • columnFilter
    A DTSEventColumnFilter with values set to true or false, depending on if the column is included (true) or excluded (false).

範例

The following code example creates a Package and selects a log provider for it. The code example then sets the fields of the DTSEventColumnFilter to true to include that field in the log, or false to exclude the field from the log. The SetColumnFilter then defines that the fields with a value of true are logged when the package incurs an OnError event. A new DTSEventColumnFilter is created, and filled with the values from the existing filter using GetColumnFilter.

using System;
using System.Collections.Generic;
using System.Text;
using Microsoft.SqlServer.Dts.Runtime;

namespace HttpClientConn
{
    class Program
    {
        static void Main(string[] args)
        {
            Package pkg = new Package();
            LogProvider log1 = pkg.LogProviders.Add("DTS.LogProviderTextFile.1");
            pkg.LoggingOptions.SelectedLogProviders.Add(log1);
            LoggingOptions lOpts = pkg.LoggingOptions;

            DTSEventColumnFilter ecf = new DTSEventColumnFilter();
            // Set the detailed information to log when the event occurs.
            // This specifies to log the Computer, Operator, and SourceName only.
            ecf.Computer = true;
            ecf.Operator = true;
            ecf.SourceName = true;
            ecf.SourceID = false;
            ecf.ExecutionID = false;
            ecf.MessageText = false;
            ecf.DataBytes = false;
            // The event is the first parameter, and the columns to log is the enumeration. 
            lOpts.SetColumnFilter("OnError", ecf);

            // Now that the column filters are set, retrieve them using 
            // GetColumnFilter.
            DTSEventColumnFilter newECF = new DTSEventColumnFilter();
            lOpts.GetColumnFilter("OnError", ref newECF);

            // Show that the new DTSEventColumnFilter has been set properly.
            Console.WriteLine("Computer: {0}", newECF.Computer);
            Console.WriteLine("Operator: {0}", newECF.Operator);
            Console.WriteLine("SourceName: {0}", newECF.SourceName);
            Console.WriteLine("SourceID: {0}", newECF.SourceID);
            Console.WriteLine("ExecutionID: {0}", newECF.ExecutionID);
            Console.WriteLine("MessageText: {0}", newECF.MessageText);
            Console.WriteLine("DataBytes: {0}", newECF.DataBytes);
        }
    }
}
Imports System
Imports System.Collections.Generic
Imports System.Text
Imports Microsoft.SqlServer.Dts.Runtime
 
Namespace HttpClientConn
    Class Program
        Shared  Sub Main(ByVal args() As String)
            Dim pkg As Package =  New Package() 
            Dim log1 As LogProvider =  pkg.LogProviders.Add("DTS.LogProviderTextFile.1") 
            pkg.LoggingOptions.SelectedLogProviders.Add(log1)
            Dim lOpts As LoggingOptions =  pkg.LoggingOptions 
 
            Dim ecf As DTSEventColumnFilter =  New DTSEventColumnFilter() 
            ' Set the detailed information to log when the event occurs.
            ' This specifies to log the Computer, Operator, and SourceName only.
            ecf.Computer = True
            ecf.Operator = True
            ecf.SourceName = True
            ecf.SourceID = False
            ecf.ExecutionID = False
            ecf.MessageText = False
            ecf.DataBytes = False
            ' The event is the first parameter, and the columns to log is the enumeration. 
            lOpts.SetColumnFilter("OnError", ecf)
 
            ' Now that the column filters are set, retrieve them using 
            ' GetColumnFilter.
            Dim NewECF As DTSEventColumnFilter =  New DTSEventColumnFilter() 
            lOpts.GetColumnFilter("OnError",ref NewECF)
 
            ' Show that the new DTSEventColumnFilter has been set properly.
            Console.WriteLine("Computer: {0}", NewECF.Computer)
            Console.WriteLine("Operator: {0}", NewECF.Operator)
            Console.WriteLine("SourceName: {0}", NewECF.SourceName)
            Console.WriteLine("SourceID: {0}", NewECF.SourceID)
            Console.WriteLine("ExecutionID: {0}", NewECF.ExecutionID)
            Console.WriteLine("MessageText: {0}", NewECF.MessageText)
            Console.WriteLine("DataBytes: {0}", NewECF.DataBytes)
        End Sub
    End Class
End Namespace

Sample Output:

Computer: True

Operator: True

SourceName: True

SourceID: False

ExecutionID: False

MessageText: False

DataBytes: False

執行緒安全性

Any public static (Shared in Microsoft Visual Basic) members of this type are thread safe. Any instance members are not guaranteed to be thread safe.

平台

開發平台

如需受支援的平台清單,請參閱<安裝 SQL Server 2005 的硬體和軟體需求>。

目標平台

如需受支援的平台清單,請參閱<安裝 SQL Server 2005 的硬體和軟體需求>。

請參閱

參考

LoggingOptions Class
LoggingOptions Members
Microsoft.SqlServer.Dts.Runtime Namespace