共用方式為


Enable-SCOMMonitor

在 Operations Manager 中啟用監視。

Syntax

Enable-SCOMMonitor
      [-Monitor] <ManagementPackMonitor[]>
      [-ManagementPack] <ManagementPack>
      [-Enforce]
      [-PassThru]
      [-WhatIf]
      [-Confirm]
      [<CommonParameters>]
Enable-SCOMMonitor
      [-Monitor] <ManagementPackMonitor[]>
      [[-Group] <MonitoringObject[]>]
      [-ManagementPack] <ManagementPack>
      [-Enforce]
      [-PassThru]
      [-WhatIf]
      [-Confirm]
      [<CommonParameters>]
Enable-SCOMMonitor
      [-Monitor] <ManagementPackMonitor[]>
      [-Class] <ManagementPackClass[]>
      [-ManagementPack] <ManagementPack>
      [-Enforce]
      [-PassThru]
      [-WhatIf]
      [-Confirm]
      [<CommonParameters>]
Enable-SCOMMonitor
      [-Monitor] <ManagementPackMonitor[]>
      [[-Instance] <MonitoringObject[]>]
      [-ManagementPack] <ManagementPack>
      [-Enforce]
      [-PassThru]
      [-WhatIf]
      [-Confirm]
      [<CommonParameters>]

Description

Enable-SCOMMonitor Cmdlet 可在 System Center - Operations Manager 中啟用監視。 在 Operations Manager 中,監視會定義決定物件健康情況的邏輯。

範例

範例 1:啟用監視器

PS C:\>$MP = Get-SCOMManagementPack -Displayname "My SQL MP Customization" | where {$_.Sealed -eq $False}
PS C:\> $Class = Get-SCOMClass -DisplayName "SQL DB Engine"
PS C:\> $Monitor = Get-SCOMMonitor -DisplayName "*memory*"
PS C:\> Enable-SCOMMonitor -Class $Class -ManagementPack $MP -Monitor $Monitor -Enforce

此範例會啟用 Operations Manager 監視器。

第一個命令會使用 Get-SCOMManagementPack Cmdlet 來取得管理元件物件,並將結果儲存在名為 $MP 的變數中。

第二個命令會使用 Get-SCOMClass Cmdlet 來取得類別物件,並將結果儲存在名為 $Class的變數中。

第三個命令會使用 Get-SCOMMonitor Cmdlet 來取得監視物件,並將結果儲存在名為 $Monitor 的變數中。

第四個命令會使用 Enable-SCOMMonitor Cmdlet,使用 Enforce 參數來啟用監視器。

參數

-Class

指定類別物件的陣列。 如需如何取得類別對象的資訊,請輸入 “Get-Help Get-SCOMClass

Type:ManagementPackClass[]
Position:1
Default value:None
Required:True
Accept pipeline input:False
Accept wildcard characters:False

-Confirm

在執行 Cmdlet 前提示您確認。

Type:SwitchParameter
Aliases:cf
Position:Named
Default value:False
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Enforce

表示 Cmdlet 會將覆寫上的 Enforce 屬性設定為$True。

Type:SwitchParameter
Position:3
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-Group

指定群組物件的陣列。 如需如何取得群組物件的資訊,請輸入 “Get-Help Get-SCOMGroup

Type:MonitoringObject[]
Position:1
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-Instance

指定類別實例物件的陣列。 Instance 參數也會接受群組物件做為輸入。 如需如何取得類別實例對象的詳細資訊,請輸入 “Get-Help Get-SCOMClassInstance ” ”

Type:MonitoringObject[]
Position:1
Default value:None
Required:False
Accept pipeline input:True
Accept wildcard characters:False

-ManagementPack

指定一或多個管理元件物件,您可以在其中儲存覆寫。 如果監視器位於未密封的管理元件中,您必須將覆寫儲存到相同的管理元件中。 如需如何取得管理元件對象的詳細資訊,請輸入 “Get-Help Get-SCOMManagementPack ”。

Type:ManagementPack
Position:1
Default value:None
Required:True
Accept pipeline input:False
Accept wildcard characters:False

-Monitor

指定監視物件的陣列。 如需如何取得監視物件的資訊,請輸入 “Get-Help Get-SCOMMonitor

Type:ManagementPackMonitor[]
Position:2
Default value:None
Required:True
Accept pipeline input:False
Accept wildcard characters:False

-PassThru

表示 Cmdlet 會建立或修改命令可以在管線中使用的物件。 根據預設,此 Cmdlet 不會產生任何輸出。

Type:SwitchParameter
Position:4
Default value:None
Required:False
Accept pipeline input:False
Accept wildcard characters:False

-WhatIf

顯示執行 Cmdlet 後會發生的情況。 Cmdlet 並不會執行。

Type:SwitchParameter
Aliases:wi
Position:Named
Default value:False
Required:False
Accept pipeline input:False
Accept wildcard characters:False