Microsoft 端點Configuration Manager版本 2103 的更新彙總套件
適用于:Configuration Manager (最新分支版本 2103)
KB10036164摘要
本文說明 Microsoft 端點Configuration Manager最新分支版本 2103 的此更新彙總套件中修正的問題。 此更新適用于透過 PowerShell 腳本加入宣告早期更新通道部署的客戶,以及安裝全域可用版本的客戶。 如需Configuration Manager 2103 版變更的詳細資訊,請參閱:
已修正的問題
在下列情況下,部署作業系統映射可能會失敗:
- 映射是使用獨立媒體部署,例如 USB 磁片磁碟機。
- 電腦會在兩個 安裝 應用程式工作順序步驟之間重新開機。
- 第一個 [安裝應用程式 ] 工作順序步驟未啟用 [發生 錯誤時繼續 ] 選項。
發生此問題時,類似下列的錯誤會記錄在 中
smsts.log
。App install failed. ... Install application action failed: '{*application_name*}'. Error Code 0x80004005 Sending error status message The client GUID must be set in an environment variable. GetClientIDs() failed. 80004005 GetClientIDs (sClientIdentity, sClientGUID_Ext), HRESULT=80004005 Non fatal error 0x80004005 in sending task sequence execution status message to Management Point Install application action cannot continue. ContinueOnErrorFlag is set to false. Install Static Applications failed, hr=0x80004005 Process completed with exit code 2147500037 Failed to run the action: Install Application. Error -2147467259
- 安裝 套件 工作順序步驟會在下列情況下無限期重複:
- 使用 「設定動態變數 」工作定義的套件會作為 安裝封裝 工作順序步驟的一部分。
- 相同的程式會多次呼叫,而且該程式會傳回暫止的重新開機結束代碼 3010。
- 在傳回 3010 結束代碼的程式第二次執行之後,電腦會重新開機。
- Import-CMQuery PowerShell Cmdlet 在更新為 Configuration Manager 2103 版之後,因 MOF 編譯錯誤而失敗。
- 選取部署詳細資料中的 [參考]索引標籤之後,選取 [工作順序] 節點會導致主控台意外終止。
- 如果替代內容提供者 (ACP) 正在使用中,且用戶端在下載程式期間切換到不同的網路,Microsoft 更新的內容將無法下載。 檔案中
ctm.log
會記錄類似下列的錯誤。CTM job {GUID} encountered error 0x80070057 during download ('Sccm Client is IBCM')- The error is non retriable. CTM encountered error processing reply from DTS. Code 0x80004004
- 如果用戶端無法連絡內部管理點,則從雲端管理閘道 (CMG) 的用戶端安裝會失敗。 檔案
ccmsetup.log
包含類似下列的錯誤。Failed to correctly receive a WEBDAV HTTPS request.. (StatusCode at WinHttpQueryHeaders: 405)
- 如果應用程式屬性的 [關鍵字 ] 欄位中有單引號,應用程式就不會如預期般出現在軟體中心。 和
cidownloader.log
cistore.log
檔案包含類似下列的錯誤。m_spCIStore->StoreCI(spIEnum), HRESULT=87d00215 CCIStore::GetCIEx - Requested CI ModelName ScopeId_{GUID}/Application_{GUID}, Version 25 not found in [Store] (0x87d00215).
- 已啟用 [以高效能 電源計劃 執行] 選項執行的工作順序,不會在執行完成時還原為先前定義的電源計劃。
- 如果必要的排程工作順序嘗試在就地升級期間執行,且用戶端處於布建模式,則排程的工作順序和升級會失敗。 這是因為當用戶端處於布建模式時,排程的工作順序會失敗,然後清除工作順序環境。 這接著會導致就地升級失敗。 包含
smsts.log
類似下列的錯誤。Install Software failed to run command line, hr=0x80070002 Process completed with exit code 2147942402 Failed to run the action: Collect Post-Upgrade Computer Data. Error -2147024894 Management Point name must be set in an environment variable
- 如果您將 [目的地] 欄位下儲存在變數中的 [邏輯磁碟機號] 選項設定為變數_OSDDetectedWinDrive,則 [套用作業系統] 工作會失敗。 變數不正確地將反斜線字元新增至磁碟機號,導致後續作業失敗。 檔案中
smsts.log
會記錄類似下列的錯誤。Set command line: "OSDApplyOS.exe" /image:PRI00001,1 /target:C:\ /runfromnet:False ... CDisk::IsLocalHardDrive(volume), HRESULT=80070057 The drive letter 125 does not correspond to a local hard drive. The requested target could not be resolved to a valid volume on this computer. Check your task sequence to ensure this drive is correct and that it is being created The parameter is incorrect. (Error: 80070057; Source: Windows) Process completed with exit code 2147942487 Failed to run the action: Apply Operating System. Error -2147024809 ... The execution of the group (Install Operating System) has failed and the execution has been aborted. An action failed. Error 0x80004004 Failed to run the last action: Apply Operating System. Result -2147024809. Execution of task sequence failed.
- 如果管理點設定為僅限網際網路通訊,則透過雲端管理閘道使用開機媒體部署作業系統可能會失敗。 檔案中
TSMBootstrap.log
會記錄類似下列的錯誤。Error. Status code 500 - (CMGConnector_InternalServerError) returned RequestMPKeyInformation: Send() failed. MPKeyInformation.RequestMPKeyInformationForMedia(szTrustedRootKey), HRESULT=80004005 Failed to get information for MP
- SMS Executive Service ()
smsexec.exe
在下列任一情況下意外終止。- 如果在Microsoft Entra群組探索程式期間發生要求逾時。
- 在規則處理期間,如果自動部署規則 (
ADR
) 包含少於兩個規則動作。
此更新中包含的 Hotfix
- 適用于 Microsoft 端點的 KB 9603111 Update Configuration Manager 2103 版早期更新通道
- 適用于 Microsoft 端點Configuration Manager版本 2103 的 KB 9833643主控台更新
Microsoft 端點Configuration Manager最新分支版本 2103 的更新資訊
針對使用早期更新通道或 2103 版全域可用組建所安裝的環境,Configuration Manager主控台的匯報和服務節點中提供此更新。
CONFIGURATION MANAGER技術採用計畫 (TAP) 的成員必須先套用私人 TAP 匯總,才能顯示此更新。
若要確認正在使用哪一個組建,請在主控台中,將 [套件 GUID] 資料行新增至 [匯報和服務] 節點的詳細資料窗格,以尋找套件 GUID。 此更新適用于來自具有下列 GUID 之套件的安裝:
- 41F02C4C-BB4B-4B8D-9299-059860339DAB
- ADADCCD5-B406-4752-91C1-C67F3024A8BD
- A052B360-A8CF-43CE-BFF8-D5DF4D14DAEC
- 6232ED65-9931-4C7D-9A6B-DD99B56478DB
- A682F854-A8AF-4F25-83B0-D9CFDFAFE659
- 8F4FEBB7-F5C4-4D73-893F-29042015727F
此更新也適用于已安裝私人 TAP 匯總 (1F2BD028-C818-4626-B088-49E354775B6F) 的 TAP 組建。 2103 媒體的新安裝與舊版的更新不同,不會列出任何套件 GUID。
重新開機資訊
此更新不需要重新開機電腦,但會在安裝之後起始 月臺重設 。
其他安裝資訊
在主要月臺上安裝此更新之後,必須手動更新既有的次要月臺。 若要在 Configuration Manager 主控台中更新次要月臺,請選取 [管理>月臺設定>站> 台復原次要站台],然後選取次要月臺。 主要月臺接著會使用更新的檔案重新安裝該次要月臺。 次要月臺的組態和設定不會受到此重新安裝的影響。 該主要月臺下的新、升級和重新安裝次要月臺會自動接收此更新。
在月臺資料庫上執行下列SQL Server命令,以檢查次要月臺的更新版本是否符合其父主要月臺的更新版本:
select dbo.fnGetSecondarySiteCMUpdateStatus ('SiteCode_of_secondary_site')
如果傳回值 1,月臺會是最新狀態,且其父主要月臺上已套用所有 Hotfix。
如果傳回值 0,月臺就不會安裝套用至主要月臺的所有修正程式,而且您應該使用 [ 復原次要月臺 ] 選項來更新次要月臺。
版本資訊
下列主要元件會更新為指定的版本:
元件 | 版本 |
---|---|
Configuration Manager主控台 | 5.2103.1059.3100 |
用戶端 | 5.0.9049.1035 |
檔案資訊
檔案資訊可在可下載的 KB10036164_FileList.txt 文字檔中取得。
版本歷程記錄
- 2021 年 6 月 11 日:初始 Hotfix 版本