downloadAnother quarterly Update Rollup (UR) has been released for System Center 2012 SP1 and SC 2012 R2. In this post we focus on SC VMM and SC Orchestrator updates. A note about Update Rollups: do not consider these optional. Do not consider them hotfixes. Install them always when they are released. Each UR contains up to 25 fixes per product based on past releases. Here’s what is new with UR’s:

 

 

Description of the fixes in Update Rollup 5 for System Center Orchestrator 2012 SP1

https://support.microsoft.com/kb/2904725

Resolved issues

Update Rollup 5 for System Center Orchestrator 2012 SP1 resolves the following issues. 

Issue 1

The Monitor Service activity does not let the configuration be saved if Monitor Service cannot resolve the hostname that is entered in the Computer Input property. If you try to save the configuration, you receive the following error message:

Connection to the selected computer has failed

Issue 2

The Compress Files activity does not include files that are in subfolders that match the filter when the Include files in sub-folders option is selected.

Issue 3

The Send SNMP Trap activity does not send the correct results for certain combinations of values.

Issue 4

The SNMP Trap Variables are not retained in the correct order after the Properties dialog box is closed and then opened again.

 

Description of Update Rollup 1 for System Center 2012 R2 Virtual Machine Manager

https://support.microsoft.com/kb/2904712

There are special install instructions for this update. Please read the article!

Issues

Update Rollup 1 for System Center 2012 R2 Virtual Machine Manager resolves the following issues:

  • System Center 2012 R2 Virtual Machine Manager cannot deploy a new or imported VMWare template.

  • A virtual machine with that uses VHDX cannot be refreshed correctly in System Center 2012 R2 Virtual Machine Manager, and you receive the following error message:

    Refresh job failed with error 2912: The requested operation cannot be performed on the virtual disk as it is currently used in shared mode (0xC05CFF0A)

  • Database operations sometimes fail with "FailedToAcquireLockException."

  • A new virtual machine template from a template that specifies an operating system profile doesn't use credentials from the operating system profile.

  • Virtual machines in VMWare that connect by the using Cisco N1000V dvSwitch are unavailable for management from Virtual Machine Manager.

  • System Center Virtual Machine Manager service crashes if you disable one of the teamed network adapters.

  • The Get-Scstoragearray -host command should return storage arrays that are visible to a host that is using zoning.

  • During the discovery of a network-attached storage (NAS) provider, the credentials that are used do not include a domain name.

  • Some localized strings are not displayed correctly in the UI.

  • A query to find the certificate should match both the subject name and the friendly name because FindBySubjectName is a wildcard search.

  • Template deployment fails, and you receive the following error message:

    Error (2904)
    VMM could not find the specified path on the <Server name> server.
    The system cannot find the path specified (0x80070003)

  • Virtual Hard Disk (VHD) cannot be mounted on a host because VHD conflicts with other disks because of a stale entry that was left in the dictionary of Virtual Machine Manager memory.

  • Differencing disk based deployment may fail because the parent disk is being refreshed as noncached.

 

 