Change Tracking - Configuration via Script
Change Tracking configuration is stored together with ISA configuration, in a VPS (Vendor Parameter Set). Note that it's a different VPS than the change log! As we already know, you can configure Change Tracking either on the array or on the enterprise. This is implemented as one VPS for each array, and one for the whole enterprise.
You can configure enable/disable Change Tracking via a script which changes these VPSs. Note that the following script always changes the enterprise VPS on ISA Enterprise Edition - changing that to change just the current array is left as an exercise to the reader.
const fpcIsaStandardEdition = &H10& const fpcIsaEnterpriseEdition = &H20& Set fpc = CreateObject("FPC.Root") If fpc.IsaEdition = fpcIsaStandardEdition Then Set VendorSets = fpc.GetContainingArray.VendorParametersSets Else Set VendorSets = fpc.Enterprise.VendorParametersSets End If On Error Resume Next Set VendorSet = VendorSets.Item( "{123558F0-6D04-4781-AC2B-5C54DCEDBCFD}" ) If Err.Number <> 0 Then Err.Clear On Error GoTo 0 Set VendorSet = VendorSets.Add( "{123558F0-6D04-4781-AC2B-5C54DCEDBCFD}" ) End If On Error GoTo 0 VendorSet("Enabled") = True 'VendorSet("AskDescription") = False 'VendorSet("MaxEntries") = 1000 VendorSets.Save 0, 0 WScript.Echo "Change Tracking is now enabled"
[TMG Update] In TMG, Change Tracking is enabled by default, so there's little need to configure it. If needed, you can do it through the ChangeTracking API:
const fpcIsaStandardEdition = &H10 const fpcIsaEnterpriseEdition = &H20 Set fpc = CreateObject("FPC.Root") If fpc.IsaEdition = fpcIsaStandardEdition Then Set ChangeTracking = fpc.GetContainingArray.ChangeTracking Else Set ChangeTracking = fpc.Enterprise.ChangeTracking End If 'ChangeTracking.Enabled = False ' Nooooooooooooooo! ChangeTracking.MaxEntries = 2000 ChangeTracking.Save 0, 0 WScript.Echo "Change Tracking max entries now set to 2000"
-Jonathan Barner, ISA Sustained Engineering Team