IOCTL_HAL_SET_DEVICE_INFO (Windows CE 5.0)
This IOCTL is called to set the data returned by IOCTL_HAL_GET_DEVICE_INFO.
The OEMIoControl function calls this IOCTL.
Parameters
dwIoControlCode
[in] Set to IOCTL_HAL_SET_DEVICE_INFO.lpInBuf
[in]Points to a buffer that can contain a string and a DWORD that represents the data to be changed.This DWORD is at the front of the string and can be set to one of the following values: SPI_GETPLATFORMTYPE or SPI_GETOEMINFO.
The string can be any string and length that is supported by the hardware platform.
nInBufSize
[in] Set to the size of the buffer pointed to by lpInBuf.lpOutBuf
[in] Set to NULL.nOutBufSize
[in] Set to 0.lpBytesReturned
[in] Set to NULL.
Remarks
Only enable this IOCTL in a test platform, not on a retail device. This IOCTL provides a way to take a platform, such as a CEPC, and force it to mimic another device type.
The following code example shows how to implement IOCTL_HAL_SET_DEVICE_INFO.
case IOCTL_HAL_SET_DEVICE_INFO:
if (nInBufSize >= sizeof(DWORD)) {
len = *(LPDWORD)lpInBuf;
switch (len) {
case SPI_GETPLATFORMTYPE :
nInBufSize -= sizeof(DWORD);
if (nInBufSize <= sizeof(HALPlatformStr)){
memcpy (HALPlatformStr, ((LPBYTE)lpInBuf)+sizeof(DWORD), nInBufSize);
retval = TRUE;
} else {
SetLastError(ERROR_INVALID_PARAMETER);
}
break;
default :
SetLastError(ERROR_INVALID_PARAMETER);
break;
}
} else {
SetLastError(ERROR_INVALID_PARAMETER);
}
break;
Requirements
OS Versions: Windows CE .NET 4.0 and later.
Header: Pkfuncs.h.
See Also
IOCTL_HAL_GET_DEVICE_INFO | OEMIoControl