System.Performance.DeltaDataProvider
Applies To: Operations Manager 2007 R2
The System.Performance.DeltaDataProvider is a data source module type that outputs a calculated delta of Windows performance data as System.Performance.Data data on a timed interval.
Usage
This module outputs the delta of the specified number of sample performance data at the specified frequency.
Type Definition
<DataSourceModuleType ID="System.Performance.DeltaDataProvider" Accessibility="Public">
<Configuration>
<xsd:element name="ComputerName" type="xsd:string" minOccurs="0" maxOccurs="1" />
<xsd:element name="CounterName" type="xsd:string" />
<xsd:element name="ObjectName" type="xsd:string" />
<xsd:element name="InstanceName" type="xsd:string" minOccurs="0" maxOccurs="1" />
<xsd:element name="AllInstances" type="xsd:boolean" minOccurs="0" maxOccurs="1" />
<xsd:element name="Frequency" type="xsd:unsignedInt" />
<xsd:element name="ScaleBy" type="xsd:double" minOccurs="0" maxOccurs="1" />
<xsd:element name="NumSamples" type="xsd:unsignedInt" />
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="Frequency" ParameterType="int" Selector="$Config/Frequency$" />
</OverrideableParameters>
<ModuleImplementation>
<Composite>
<MemberModules>
<DataSource TypeID="System.Performance.DataProvider" ID="DataSource">
<ComputerName>$Config/ComputerName$</ComputerName>
<CounterName>$Config/CounterName$</CounterName>
<ObjectName>$Config/ObjectName$</ObjectName>
<InstanceName>$Config/InstanceName$</InstanceName>
<AllInstances>$Config/AllInstances$</AllInstances>
<Frequency>$Config/Frequency$</Frequency>
<ScaleBy>$Config/ScaleBy$</ScaleBy>
</DataSource>
<ConditionDetection TypeID="System.Performance.DeltaValueCondition" ID="Delta">
<NumSamples>$Config/NumSamples$</NumSamples>
<Absolute>true</Absolute>
</ConditionDetection>
</MemberModules>
<Composition>
<Node ID="Delta">
<Node ID="DataSource" />
</Node>
</Composition>
</Composite>
</ModuleImplementation>
<OutputType>System.Performance.Data</OutputType>
</DataSourceModuleType>
Parameters
The System.Performance.DeltaDataProvider supports the configuration parameters described in the following table.
Parameter | Type | Overrideable | Description |
---|---|---|---|
ComputerName |
String |
False |
Optional parameter. Contains the name of the computer to collect performance data from. |
CounterName |
String |
False |
Required parameter. Specifies the name of the Windows performance counter. |
ObjectName |
String |
False |
Required parameter. Specifies the Windows performance object name. |
InstanceName |
String |
False |
Optional parameter. Contains the Windows performance instance, if applicable. |
AllInstances |
Boolean |
False |
Optional parameter. Specifies whether to collect all instances for a multi-instance counter. Defaults to false. |
Frequency |
Unsigned Integer |
True |
Required parameter. Specifies the interval in seconds between performance data collection. Data might not actually be output from the module on this frequency if optimization is being used. Must be greater than 0. |
ScaleBy |
Double |
False |
Operations Manager 2007 R2 only. Optional parameter. Specifies the scale value of the raw performance counter value to make that value more readable. Defaults to 1.0. |
NumSamples |
Unsigned Integer |
False |
Required parameter. Contains the number of samples over which to calculate the delta difference. |
For more information about the parameters in this module see System.Performance.DeltaValueCondition and System.Performance.DataProvider.
Composition
The System.Performance.DeltaDataProvider composite module contains the member modules described in the following table.
Workflow Run Order | Module Type | Usage |
---|---|---|
1 |
Provides the performance data from the specified counter. |
|
2 |
Calculates the delta value of the specified number of incoming performance data samples. |
Related Modules
None.
External Module References
None.
Remarks
For remarks, see System.Performance.DataProvider.
Sample
The following XML example is a UnitMonitorType definition that can be used to create a two-state threshold UnitMonitor element that uses the delta value of sampled performance data to determine monitor health state.
<UnitMonitorType ID="System.Performance.DeltaThreshold" Accessibility="Public">
<MonitorTypeStates>
<MonitorTypeState ID="UnderThreshold" />
<MonitorTypeState ID="OverThreshold" />
</MonitorTypeStates>
<Configuration>
<xsd:element name="ComputerName" type="xsd:string" minOccurs="0" maxOccurs="1" />
<xsd:element name="CounterName" type="xsd:string" />
<xsd:element name="ObjectName" type="xsd:string" />
<xsd:element name="InstanceName" type="xsd:string" minOccurs="0" maxOccurs="1" />
<xsd:element name="AllInstances" type="xsd:boolean" minOccurs="0" maxOccurs="1" />
<xsd:element name="Frequency" type="xsd:unsignedInt" />
<xsd:element name="ScaleBy" type="xsd:double" minOccurs="0" maxOccurs="1" />
<xsd:element minOccurs="1" maxOccurs="1" name="Threshold" type="xsd:double" />
<xsd:element minOccurs="1" maxOccurs="1" name="NumSamples" type="xsd:unsignedInt" />
<xsd:element minOccurs="1" maxOccurs="1" name="Absolute">
<xsd:simpleType>
<xsd:restriction base="xsd:string">
<xsd:enumeration value="true" />
<xsd:enumeration value="false" />
</xsd:restriction>
</xsd:simpleType>
</xsd:element>
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="Frequency" ParameterType="int" Selector="$Config/Frequency$" />
<OverrideableParameter ID="Threshold" ParameterType="double" Selector="$Config/Threshold$" />
</OverrideableParameters>
<MonitorImplementation>
<MemberModules>
<DataSource TypeID="System.Performance.DeltaDataProvider" ID="DS1">
<ComputerName>$Config/ComputerName$</ComputerName>
<CounterName>$Config/CounterName$</CounterName>
<ObjectName>$Config/ObjectName$</ObjectName>
<InstanceName>$Config/InstanceName$</InstanceName>
<AllInstances>$Config/AllInstances$</AllInstances>
<Frequency>$Config/Frequency$</Frequency>
<ScaleBy>$Config/ScaleBy$</ScaleBy>
<NumSamples>$Config/NumSamples$</NumSamples>
</DataSource>
<ConditionDetection TypeID="System!System.ExpressionFilter" ID="CDOverThreshold">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Double">Value</XPathQuery>
</ValueExpression>
<Operator>Greater</Operator>
<ValueExpression>
<Value Type="Double">$Config/Threshold$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</ConditionDetection>
<ConditionDetection TypeID="System!System.ExpressionFilter" ID="CDUnderThreshold">
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Double">Value</XPathQuery>
</ValueExpression>
<Operator>LessEqual</Operator>
<ValueExpression>
<Value Type="Double">$Config/Threshold$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</ConditionDetection>
</MemberModules>
<RegularDetections>
<RegularDetection MonitorTypeStateID="UnderThreshold">
<Node ID="CDUnderThreshold">
<Node ID="CDDeltaThreshold">
<Node ID="DS1" />
</Node>
</Node>
</RegularDetection>
<RegularDetection MonitorTypeStateID="OverThreshold">
<Node ID="CDOverThreshold">
<Node ID="CDDeltaThreshold">
<Node ID="DS1" />
</Node>
</Node>
</RegularDetection>
</RegularDetections>
</MonitorImplementation>
</UnitMonitorType>
Below is a sample data item that could be returned by the System.Performance.DeltaDataProvider module. The Value
element represents the delta value of the specified number of samples taken. The FirstValue
and LastValue
elements represent the first sample value and the last sample value respectively.
<DataItem type="System.Performance.Data" time="2008-03-11T03:08:55.0343534-08:00" sourceHealthServiceId="0A0800A0-A802-E90B-6045-D961D516CA78">
<TimeSampled>2008-03-11T03:08:55.0343534-08:00</TimeSampled>
<ObjectName>LC:SIP - 01 - Peers</ObjectName>
<CounterName>SIP - 018 - Sends Timed-Out</CounterName>
<InstanceName>_Total</InstanceName>
<IsNull Type="Boolean">false</IsNull>
<Value>2</Value>
<SampleCount>2</SampleCount>
<FirstValue>1010</FirstValue>
<LastValue>1012</LastValue>
</DataItem>
Information
Module Type |
|
InputType |
None |
Output Type |
|
Implementation |
Composite |
Library |
System.Performance.Library |