Redigera

Dela via


ICE79

ICE79 validates the references to components and features entered in the database fields using the Condition data type.

Result

ICE79 posts two warnings.

ICE79 warning Description
Database is missing _Validation table. Could not completely check property names. Database is missing _Validation table.
Error retrieving values from column [2] in table [1]. Skipping Column. Error retrieving value.

 

ICE79 posts two errors.

ICE79 error Description
Component '%ls' referenced in column '%s'.'%s' of row %s is invalid. An invalid component reference was found.
Feature '%ls' referenced in column '%s'.'%s' of row %s is invalid. An invalid feature reference was found

 

Example

ICE79 reports the following errors for the example:

Component 'NoSuchComponent' referenced in column 
'InstallExecuteSequence'.'Condition' of row Custom2 is invalid.
Feature 'NoSuchFeature' referenced in column 
'InstallExecuteSequence'.'Condition' of row Custom1 is invalid.

In this example, NoSuchComponent is absent from the Component table and NoSuchFeature is absent from the Feature table.

InstallExecuteSequence Table (partial)

Action Condition
Custom1 TESTACTION=1046 AND &NoSuchFeature>2
Custom2 TESTACTION=146 AND $NoSuchComponent>2

 

To fix these errors, enter valid records for NoSuchFeature and NoSuchComponent in the Feature and Component tables.