Redigera

Dela via


System Error Codes (0-499)

The following list describes system error codes (errors 0 to 499). They are returned by the GetLastError function when many functions fail. To retrieve the description text for the error in your application, use the FormatMessage function with the FORMAT_MESSAGE_FROM_SYSTEM flag.

Note

This information is intended for developers debugging system errors. For other errors, such as issues with Windows Update, see the list of resources on the Error codes page.

ERROR_SUCCESS

0 (0x0)

The operation completed successfully.

ERROR_INVALID_FUNCTION

1 (0x1)

Incorrect function.

ERROR_FILE_NOT_FOUND

2 (0x2)

The system cannot find the file specified.

ERROR_PATH_NOT_FOUND

3 (0x3)

The system cannot find the path specified.

ERROR_TOO_MANY_OPEN_FILES

4 (0x4)

The system cannot open the file.

ERROR_ACCESS_DENIED

5 (0x5)

Access is denied.

ERROR_INVALID_HANDLE

6 (0x6)

The handle is invalid.

ERROR_ARENA_TRASHED

7 (0x7)

The storage control blocks were destroyed.

ERROR_NOT_ENOUGH_MEMORY

8 (0x8)

Not enough memory resources are available to process this command.

ERROR_INVALID_BLOCK

9 (0x9)

The storage control block address is invalid.

ERROR_BAD_ENVIRONMENT

10 (0xA)

The environment is incorrect.

ERROR_BAD_FORMAT

11 (0xB)

An attempt was made to load a program with an incorrect format.

ERROR_INVALID_ACCESS

12 (0xC)

The access code is invalid.

ERROR_INVALID_DATA

13 (0xD)

The data is invalid.

ERROR_OUTOFMEMORY

14 (0xE)

Not enough storage is available to complete this operation.

ERROR_INVALID_DRIVE

15 (0xF)

The system cannot find the drive specified.

ERROR_CURRENT_DIRECTORY

16 (0x10)

The directory cannot be removed.

ERROR_NOT_SAME_DEVICE

17 (0x11)

The system cannot move the file to a different disk drive.

ERROR_NO_MORE_FILES

18 (0x12)

There are no more files.

ERROR_WRITE_PROTECT

19 (0x13)

The media is write protected.

ERROR_BAD_UNIT

20 (0x14)

The system cannot find the device specified.

ERROR_NOT_READY

21 (0x15)

The device is not ready.

ERROR_BAD_COMMAND

22 (0x16)

The device does not recognize the command.

ERROR_CRC

23 (0x17)

Data error (cyclic redundancy check).

ERROR_BAD_LENGTH

24 (0x18)

The program issued a command but the command length is incorrect.

ERROR_SEEK

25 (0x19)

The drive cannot locate a specific area or track on the disk.

ERROR_NOT_DOS_DISK

26 (0x1A)

The specified disk or diskette cannot be accessed.

ERROR_SECTOR_NOT_FOUND

27 (0x1B)

The drive cannot find the sector requested.

ERROR_OUT_OF_PAPER

28 (0x1C)

The printer is out of paper.

ERROR_WRITE_FAULT

29 (0x1D)

The system cannot write to the specified device.

ERROR_READ_FAULT

30 (0x1E)

The system cannot read from the specified device.

ERROR_GEN_FAILURE

31 (0x1F)

A device attached to the system is not functioning.

ERROR_SHARING_VIOLATION

32 (0x20)

The process cannot access the file because it is being used by another process.

ERROR_LOCK_VIOLATION

33 (0x21)

The process cannot access the file because another process has locked a portion of the file.

ERROR_WRONG_DISK

34 (0x22)

The wrong diskette is in the drive. Insert %2 (Volume Serial Number: %3) into drive %1.

ERROR_SHARING_BUFFER_EXCEEDED

36 (0x24)

Too many files opened for sharing.

ERROR_HANDLE_EOF

38 (0x26)

Reached the end of the file.

ERROR_HANDLE_DISK_FULL

39 (0x27)

The disk is full.

ERROR_NOT_SUPPORTED

50 (0x32)

The request is not supported.

ERROR_REM_NOT_LIST

51 (0x33)

Windows cannot find the network path. Verify that the network path is correct and the destination computer is not busy or turned off. If Windows still cannot find the network path, contact your network administrator.

ERROR_DUP_NAME

52 (0x34)

You were not connected because a duplicate name exists on the network. If joining a domain, go to System in Control Panel to change the computer name and try again. If joining a workgroup, choose another workgroup name.

ERROR_BAD_NETPATH

53 (0x35)

The network path was not found.

ERROR_NETWORK_BUSY

54 (0x36)

The network is busy.

ERROR_DEV_NOT_EXIST

55 (0x37)

The specified network resource or device is no longer available.

ERROR_TOO_MANY_CMDS

56 (0x38)

The network BIOS command limit has been reached.

ERROR_ADAP_HDW_ERR

57 (0x39)

A network adapter hardware error occurred.

ERROR_BAD_NET_RESP

58 (0x3A)

The specified server cannot perform the requested operation.

ERROR_UNEXP_NET_ERR

59 (0x3B)

An unexpected network error occurred.

ERROR_BAD_REM_ADAP

60 (0x3C)

The remote adapter is not compatible.

ERROR_PRINTQ_FULL

61 (0x3D)

The printer queue is full.

ERROR_NO_SPOOL_SPACE

62 (0x3E)

Space to store the file waiting to be printed is not available on the server.

ERROR_PRINT_CANCELLED

63 (0x3F)

Your file waiting to be printed was deleted.

ERROR_NETNAME_DELETED

64 (0x40)

The specified network name is no longer available.

ERROR_NETWORK_ACCESS_DENIED

65 (0x41)

Network access is denied.

ERROR_BAD_DEV_TYPE

66 (0x42)

The network resource type is not correct.

ERROR_BAD_NET_NAME

67 (0x43)

The network name cannot be found.

ERROR_TOO_MANY_NAMES

68 (0x44)

The name limit for the local computer network adapter card was exceeded.

ERROR_TOO_MANY_SESS

69 (0x45)

The network BIOS session limit was exceeded.

ERROR_SHARING_PAUSED

70 (0x46)

The remote server has been paused or is in the process of being started.

ERROR_REQ_NOT_ACCEP

71 (0x47)

No more connections can be made to this remote computer at this time because there are already as many connections as the computer can accept.

ERROR_REDIR_PAUSED

72 (0x48)

The specified printer or disk device has been paused.

ERROR_FILE_EXISTS

80 (0x50)

The file exists.

ERROR_CANNOT_MAKE

82 (0x52)

The directory or file cannot be created.

ERROR_FAIL_I24

83 (0x53)

Fail on INT 24.

ERROR_OUT_OF_STRUCTURES

84 (0x54)

Storage to process this request is not available.

ERROR_ALREADY_ASSIGNED

85 (0x55)

The local device name is already in use.

ERROR_INVALID_PASSWORD

86 (0x56)

The specified network password is not correct.

ERROR_INVALID_PARAMETER

87 (0x57)

The parameter is incorrect.

ERROR_NET_WRITE_FAULT

88 (0x58)

A write fault occurred on the network.

ERROR_NO_PROC_SLOTS

89 (0x59)

The system cannot start another process at this time.

ERROR_TOO_MANY_SEMAPHORES

100 (0x64)

Cannot create another system semaphore.

ERROR_EXCL_SEM_ALREADY_OWNED

101 (0x65)

The exclusive semaphore is owned by another process.

ERROR_SEM_IS_SET

102 (0x66)

The semaphore is set and cannot be closed.

ERROR_TOO_MANY_SEM_REQUESTS

103 (0x67)

The semaphore cannot be set again.

ERROR_INVALID_AT_INTERRUPT_TIME

104 (0x68)

Cannot request exclusive semaphores at interrupt time.

ERROR_SEM_OWNER_DIED

105 (0x69)

The previous ownership of this semaphore has ended.

ERROR_SEM_USER_LIMIT

106 (0x6A)

Insert the diskette for drive %1.

ERROR_DISK_CHANGE

107 (0x6B)

The program stopped because an alternate diskette was not inserted.

ERROR_DRIVE_LOCKED

108 (0x6C)

The disk is in use or locked by another process.

ERROR_BROKEN_PIPE

109 (0x6D)

The pipe has been ended.

ERROR_OPEN_FAILED

110 (0x6E)

The system cannot open the device or file specified.

ERROR_BUFFER_OVERFLOW

111 (0x6F)

The file name is too long.

ERROR_DISK_FULL

112 (0x70)

There is not enough space on the disk.

ERROR_NO_MORE_SEARCH_HANDLES

113 (0x71)

No more internal file identifiers available.

ERROR_INVALID_TARGET_HANDLE

114 (0x72)

The target internal file identifier is incorrect.

ERROR_INVALID_CATEGORY

117 (0x75)

The IOCTL call made by the application program is not correct.

ERROR_INVALID_VERIFY_SWITCH

118 (0x76)

The verify-on-write switch parameter value is not correct.

ERROR_BAD_DRIVER_LEVEL

119 (0x77)

The system does not support the command requested.

ERROR_CALL_NOT_IMPLEMENTED

120 (0x78)

This function is not supported on this system.

ERROR_SEM_TIMEOUT

121 (0x79)

The semaphore timeout period has expired.

ERROR_INSUFFICIENT_BUFFER

122 (0x7A)

The data area passed to a system call is too small.

ERROR_INVALID_NAME

123 (0x7B)

The filename, directory name, or volume label syntax is incorrect.

ERROR_INVALID_LEVEL

124 (0x7C)

The system call level is not correct.

ERROR_NO_VOLUME_LABEL

125 (0x7D)

The disk has no volume label.

ERROR_MOD_NOT_FOUND

126 (0x7E)

The specified module could not be found.

ERROR_PROC_NOT_FOUND

127 (0x7F)

The specified procedure could not be found.

ERROR_WAIT_NO_CHILDREN

128 (0x80)

There are no child processes to wait for.

ERROR_CHILD_NOT_COMPLETE

129 (0x81)

The %1 application cannot be run in Win32 mode.

ERROR_DIRECT_ACCESS_HANDLE

130 (0x82)

Attempt to use a file handle to an open disk partition for an operation other than raw disk I/O.

ERROR_NEGATIVE_SEEK

131 (0x83)

An attempt was made to move the file pointer before the beginning of the file.

ERROR_SEEK_ON_DEVICE

132 (0x84)

The file pointer cannot be set on the specified device or file.

ERROR_IS_JOIN_TARGET

133 (0x85)

A JOIN or SUBST command cannot be used for a drive that contains previously joined drives.

ERROR_IS_JOINED

134 (0x86)

An attempt was made to use a JOIN or SUBST command on a drive that has already been joined.

ERROR_IS_SUBSTED

135 (0x87)

An attempt was made to use a JOIN or SUBST command on a drive that has already been substituted.

ERROR_NOT_JOINED

136 (0x88)

The system tried to delete the JOIN of a drive that is not joined.

ERROR_NOT_SUBSTED

137 (0x89)

The system tried to delete the substitution of a drive that is not substituted.

ERROR_JOIN_TO_JOIN

138 (0x8A)

The system tried to join a drive to a directory on a joined drive.

ERROR_SUBST_TO_SUBST

139 (0x8B)

The system tried to substitute a drive to a directory on a substituted drive.

ERROR_JOIN_TO_SUBST

140 (0x8C)

The system tried to join a drive to a directory on a substituted drive.

ERROR_SUBST_TO_JOIN

141 (0x8D)

The system tried to SUBST a drive to a directory on a joined drive.

ERROR_BUSY_DRIVE

142 (0x8E)

The system cannot perform a JOIN or SUBST at this time.

ERROR_SAME_DRIVE

143 (0x8F)

The system cannot join or substitute a drive to or for a directory on the same drive.

ERROR_DIR_NOT_ROOT

144 (0x90)

The directory is not a subdirectory of the root directory.

ERROR_DIR_NOT_EMPTY

145 (0x91)

The directory is not empty.

ERROR_IS_SUBST_PATH

146 (0x92)

The path specified is being used in a substitute.

ERROR_IS_JOIN_PATH

147 (0x93)

Not enough resources are available to process this command.

ERROR_PATH_BUSY

148 (0x94)

The path specified cannot be used at this time.

ERROR_IS_SUBST_TARGET

149 (0x95)

An attempt was made to join or substitute a drive for which a directory on the drive is the target of a previous substitute.

ERROR_SYSTEM_TRACE

150 (0x96)

System trace information was not specified in your CONFIG.SYS file, or tracing is disallowed.

ERROR_INVALID_EVENT_COUNT

151 (0x97)

The number of specified semaphore events for DosMuxSemWait is not correct.

ERROR_TOO_MANY_MUXWAITERS

152 (0x98)

DosMuxSemWait did not execute; too many semaphores are already set.

ERROR_INVALID_LIST_FORMAT

153 (0x99)

The DosMuxSemWait list is not correct.

ERROR_LABEL_TOO_LONG

154 (0x9A)

The volume label you entered exceeds the label character limit of the target file system.

ERROR_TOO_MANY_TCBS

155 (0x9B)

Cannot create another thread.

ERROR_SIGNAL_REFUSED

156 (0x9C)

The recipient process has refused the signal.

ERROR_DISCARDED

157 (0x9D)

The segment is already discarded and cannot be locked.

ERROR_NOT_LOCKED

158 (0x9E)

The segment is already unlocked.

ERROR_BAD_THREADID_ADDR

159 (0x9F)

The address for the thread ID is not correct.

ERROR_BAD_ARGUMENTS

160 (0xA0)

One or more arguments are not correct.

ERROR_BAD_PATHNAME

161 (0xA1)

The specified path is invalid.

ERROR_SIGNAL_PENDING

162 (0xA2)

A signal is already pending.

ERROR_MAX_THRDS_REACHED

164 (0xA4)

No more threads can be created in the system.

ERROR_LOCK_FAILED

167 (0xA7)

Unable to lock a region of a file.

ERROR_BUSY

170 (0xAA)

The requested resource is in use.

ERROR_DEVICE_SUPPORT_IN_PROGRESS

171 (0xAB)

Device's command support detection is in progress.

ERROR_CANCEL_VIOLATION

173 (0xAD)

A lock request was not outstanding for the supplied cancel region.

ERROR_ATOMIC_LOCKS_NOT_SUPPORTED

174 (0xAE)

The file system does not support atomic changes to the lock type.

ERROR_INVALID_SEGMENT_NUMBER

180 (0xB4)

The system detected a segment number that was not correct.

ERROR_INVALID_ORDINAL

182 (0xB6)

The operating system cannot run %1.

ERROR_ALREADY_EXISTS

183 (0xB7)

Cannot create a file when that file already exists.

ERROR_INVALID_FLAG_NUMBER

186 (0xBA)

The flag passed is not correct.

ERROR_SEM_NOT_FOUND

187 (0xBB)

The specified system semaphore name was not found.

ERROR_INVALID_STARTING_CODESEG

188 (0xBC)

The operating system cannot run %1.

ERROR_INVALID_STACKSEG

189 (0xBD)

The operating system cannot run %1.

ERROR_INVALID_MODULETYPE

190 (0xBE)

The operating system cannot run %1.

ERROR_INVALID_EXE_SIGNATURE

191 (0xBF)

Cannot run %1 in Win32 mode.

ERROR_EXE_MARKED_INVALID

192 (0xC0)

The operating system cannot run %1.

ERROR_BAD_EXE_FORMAT

193 (0xC1)

%1 is not a valid Win32 application.

ERROR_ITERATED_DATA_EXCEEDS_64k

194 (0xC2)

The operating system cannot run %1.

ERROR_INVALID_MINALLOCSIZE

195 (0xC3)

The operating system cannot run %1.

ERROR_DYNLINK_FROM_INVALID_RING

196 (0xC4)

The operating system cannot run this application program.

ERROR_IOPL_NOT_ENABLED

197 (0xC5)

The operating system is not presently configured to run this application.

ERROR_INVALID_SEGDPL

198 (0xC6)

The operating system cannot run %1.

ERROR_AUTODATASEG_EXCEEDS_64k

199 (0xC7)

The operating system cannot run this application program.

ERROR_RING2SEG_MUST_BE_MOVABLE

200 (0xC8)

The code segment cannot be greater than or equal to 64K.

ERROR_RELOC_CHAIN_XEEDS_SEGLIM

201 (0xC9)

The operating system cannot run %1.

ERROR_INFLOOP_IN_RELOC_CHAIN

202 (0xCA)

The operating system cannot run %1.

ERROR_ENVVAR_NOT_FOUND

203 (0xCB)

The system could not find the environment option that was entered.

ERROR_NO_SIGNAL_SENT

205 (0xCD)

No process in the command subtree has a signal handler.

ERROR_FILENAME_EXCED_RANGE

206 (0xCE)

The filename or extension is too long.

ERROR_RING2_STACK_IN_USE

207 (0xCF)

The ring 2 stack is in use.

ERROR_META_EXPANSION_TOO_LONG

208 (0xD0)

The global filename characters, * or ?, are entered incorrectly or too many global filename characters are specified.

ERROR_INVALID_SIGNAL_NUMBER

209 (0xD1)

The signal being posted is not correct.

ERROR_THREAD_1_INACTIVE

210 (0xD2)

The signal handler cannot be set.

ERROR_LOCKED

212 (0xD4)

The segment is locked and cannot be reallocated.

ERROR_TOO_MANY_MODULES

214 (0xD6)

Too many dynamic-link modules are attached to this program or dynamic-link module.

ERROR_NESTING_NOT_ALLOWED

215 (0xD7)

Cannot nest calls to LoadModule.

ERROR_EXE_MACHINE_TYPE_MISMATCH

216 (0xD8)

This version of %1 is not compatible with the version of Windows you're running. Check your computer's system information and then contact the software publisher.

ERROR_EXE_CANNOT_MODIFY_SIGNED_BINARY

217 (0xD9)

The image file %1 is signed, unable to modify.

ERROR_EXE_CANNOT_MODIFY_STRONG_SIGNED_BINARY

218 (0xDA)

The image file %1 is strong signed, unable to modify.

ERROR_FILE_CHECKED_OUT

220 (0xDC)

This file is checked out or locked for editing by another user.

ERROR_CHECKOUT_REQUIRED

221 (0xDD)

The file must be checked out before saving changes.

ERROR_BAD_FILE_TYPE

222 (0xDE)

The file type being saved or retrieved has been blocked.

ERROR_FILE_TOO_LARGE

223 (0xDF)

The file size exceeds the limit allowed and cannot be saved.

ERROR_FORMS_AUTH_REQUIRED

224 (0xE0)

Access Denied. Before opening files in this location, you must first add the web site to your trusted sites list, browse to the web site, and select the option to login automatically.

ERROR_VIRUS_INFECTED

225 (0xE1)

Operation did not complete successfully because the file contains a virus or potentially unwanted software.

ERROR_VIRUS_DELETED

226 (0xE2)

This file contains a virus or potentially unwanted software and cannot be opened. Due to the nature of this virus or potentially unwanted software, the file has been removed from this location.

ERROR_PIPE_LOCAL

229 (0xE5)

The pipe is local.

ERROR_BAD_PIPE

230 (0xE6)

The pipe state is invalid.

ERROR_PIPE_BUSY

231 (0xE7)

All pipe instances are busy.

ERROR_NO_DATA

232 (0xE8)

The pipe is being closed.

ERROR_PIPE_NOT_CONNECTED

233 (0xE9)

No process is on the other end of the pipe.

ERROR_MORE_DATA

234 (0xEA)

More data is available.

ERROR_VC_DISCONNECTED

240 (0xF0)

The session was canceled.

ERROR_INVALID_EA_NAME

254 (0xFE)

The specified extended attribute name was invalid.

ERROR_EA_LIST_INCONSISTENT

255 (0xFF)

The extended attributes are inconsistent.

WAIT_TIMEOUT

258 (0x102)

The wait operation timed out.

ERROR_NO_MORE_ITEMS

259 (0x103)

No more data is available.

ERROR_CANNOT_COPY

266 (0x10A)

The copy functions cannot be used.

ERROR_DIRECTORY

267 (0x10B)

The directory name is invalid.

ERROR_EAS_DIDNT_FIT

275 (0x113)

The extended attributes did not fit in the buffer.

ERROR_EA_FILE_CORRUPT

276 (0x114)

The extended attribute file on the mounted file system is corrupt.

ERROR_EA_TABLE_FULL

277 (0x115)

The extended attribute table file is full.

ERROR_INVALID_EA_HANDLE

278 (0x116)

The specified extended attribute handle is invalid.

ERROR_EAS_NOT_SUPPORTED

282 (0x11A)

The mounted file system does not support extended attributes.

ERROR_NOT_OWNER

288 (0x120)

Attempt to release mutex not owned by caller.

ERROR_TOO_MANY_POSTS

298 (0x12A)

Too many posts were made to a semaphore.

ERROR_PARTIAL_COPY

299 (0x12B)

Only part of a ReadProcessMemory or WriteProcessMemory request was completed.

ERROR_OPLOCK_NOT_GRANTED

300 (0x12C)

The oplock request is denied.

ERROR_INVALID_OPLOCK_PROTOCOL

301 (0x12D)

An invalid oplock acknowledgment was received by the system.

ERROR_DISK_TOO_FRAGMENTED

302 (0x12E)

The volume is too fragmented to complete this operation.

ERROR_DELETE_PENDING

303 (0x12F)

The file cannot be opened because it is in the process of being deleted.

ERROR_INCOMPATIBLE_WITH_GLOBAL_SHORT_NAME_REGISTRY_SETTING

304 (0x130)

Short name settings may not be changed on this volume due to the global registry setting.

ERROR_SHORT_NAMES_NOT_ENABLED_ON_VOLUME

305 (0x131)

Short names are not enabled on this volume.

ERROR_SECURITY_STREAM_IS_INCONSISTENT

306 (0x132)

The security stream for the given volume is in an inconsistent state. Please run CHKDSK on the volume.

ERROR_INVALID_LOCK_RANGE

307 (0x133)

A requested file lock operation cannot be processed due to an invalid byte range.

ERROR_IMAGE_SUBSYSTEM_NOT_PRESENT

308 (0x134)

The subsystem needed to support the image type is not present.

ERROR_NOTIFICATION_GUID_ALREADY_DEFINED

309 (0x135)

The specified file already has a notification GUID associated with it.

ERROR_INVALID_EXCEPTION_HANDLER

310 (0x136)

An invalid exception handler routine has been detected.

ERROR_DUPLICATE_PRIVILEGES

311 (0x137)

Duplicate privileges were specified for the token.

ERROR_NO_RANGES_PROCESSED

312 (0x138)

No ranges for the specified operation were able to be processed.

ERROR_NOT_ALLOWED_ON_SYSTEM_FILE

313 (0x139)

Operation is not allowed on a file system internal file.

ERROR_DISK_RESOURCES_EXHAUSTED

314 (0x13A)

The physical resources of this disk have been exhausted.

ERROR_INVALID_TOKEN

315 (0x13B)

The token representing the data is invalid.

ERROR_DEVICE_FEATURE_NOT_SUPPORTED

316 (0x13C)

The device does not support the command feature.

ERROR_MR_MID_NOT_FOUND

317 (0x13D)

The system cannot find message text for message number 0x%1 in the message file for %2.

ERROR_SCOPE_NOT_FOUND

318 (0x13E)

The scope specified was not found.

ERROR_UNDEFINED_SCOPE

319 (0x13F)

The Central Access Policy specified is not defined on the target machine.

ERROR_INVALID_CAP

320 (0x140)

The Central Access Policy obtained from Active Directory is invalid.

ERROR_DEVICE_UNREACHABLE

321 (0x141)

The device is unreachable.

ERROR_DEVICE_NO_RESOURCES

322 (0x142)

The target device has insufficient resources to complete the operation.

ERROR_DATA_CHECKSUM_ERROR

323 (0x143)

A data integrity checksum error occurred. Data in the file stream is corrupt.

ERROR_INTERMIXED_KERNEL_EA_OPERATION

324 (0x144)

An attempt was made to modify both a KERNEL and normal Extended Attribute (EA) in the same operation.

ERROR_FILE_LEVEL_TRIM_NOT_SUPPORTED

326 (0x146)

Device does not support file-level TRIM.

ERROR_OFFSET_ALIGNMENT_VIOLATION

327 (0x147)

The command specified a data offset that does not align to the device's granularity/alignment.

ERROR_INVALID_FIELD_IN_PARAMETER_LIST

328 (0x148)

The command specified an invalid field in its parameter list.

ERROR_OPERATION_IN_PROGRESS

329 (0x149)

An operation is currently in progress with the device.

ERROR_BAD_DEVICE_PATH

330 (0x14A)

An attempt was made to send down the command via an invalid path to the target device.

ERROR_TOO_MANY_DESCRIPTORS

331 (0x14B)

The command specified a number of descriptors that exceeded the maximum supported by the device.

ERROR_SCRUB_DATA_DISABLED

332 (0x14C)

Scrub is disabled on the specified file.

ERROR_NOT_REDUNDANT_STORAGE

333 (0x14D)

The storage device does not provide redundancy.

ERROR_RESIDENT_FILE_NOT_SUPPORTED

334 (0x14E)

An operation is not supported on a resident file.

ERROR_COMPRESSED_FILE_NOT_SUPPORTED

335 (0x14F)

An operation is not supported on a compressed file.

ERROR_DIRECTORY_NOT_SUPPORTED

336 (0x150)

An operation is not supported on a directory.

ERROR_NOT_READ_FROM_COPY

337 (0x151)

The specified copy of the requested data could not be read.

ERROR_FAIL_NOACTION_REBOOT

350 (0x15E)

No action was taken as a system reboot is required.

ERROR_FAIL_SHUTDOWN

351 (0x15F)

The shutdown operation failed.

ERROR_FAIL_RESTART

352 (0x160)

The restart operation failed.

ERROR_MAX_SESSIONS_REACHED

353 (0x161)

The maximum number of sessions has been reached.

ERROR_THREAD_MODE_ALREADY_BACKGROUND

400 (0x190)

The thread is already in background processing mode.

ERROR_THREAD_MODE_NOT_BACKGROUND

401 (0x191)

The thread is not in background processing mode.

ERROR_PROCESS_MODE_ALREADY_BACKGROUND

402 (0x192)

The process is already in background processing mode.

ERROR_PROCESS_MODE_NOT_BACKGROUND

403 (0x193)

The process is not in background processing mode.

ERROR_INVALID_ADDRESS

487 (0x1E7)

Attempt to access invalid address.

Requirements

Requirement Value
Minimum supported client
Windows XP [desktop apps only]
Minimum supported server
Windows Server 2003 [desktop apps only]
Header
WinError.h (include Windows.h)

See also

System Error Codes