iSCSI HBA RedirectionTest (LOGO)
This test verifies that a host-bus adapter (HBA) properly handles the target device's capability to redirect the connection to a different IP address or port.
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 5 |
Category | Development |
Timeout (in minutes) | 300 |
Requires reboot | false |
Requires special configuration | true |
Type | automatic |
Additional documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
Running the test
Before you run the test, complete the test setup as described in the test requirements: iSCSI HBA Testing Prerequisites.
If this is the first time you are running an iSCSI HBA test, iSCSI Target test, or MPIO test over iSCSI bus type on the HLK client, or if there is no iscsihctconfig.ini under [HLK Path]\JobsWorkingDir\ on the HLK client, you will receive a pop-up dialog box to input iSCSI configuration information and/or HBA information. For more information about this dialog box, see "Running the test" in iSCSI HBA Boot Test (LOGO).
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.
For troubleshooting information, see Troubleshooting Device.Storage Testing.
In addition:
Look at the job results log file for test failures.
Enter the required data in the configuration dialog box that appears when this job is scheduled. For more information, go to iSCSI HBA Boot Test (LOGO).
This test always return Pass or Fail. To review test details, review the test log from the Windows HLK Manager.
More information
This test implements a simple iSCSI target. The test performs a logon to this target by using the HBA under test. The target, when it receives the first logon packet, will redirect the HBA to connect to the target by using a different location.
The test has three different variations that use different redirection mechanisms:
Redirection to a new IP address
Redirection to a new IP address and new port
Redirection to the same IP address with a new port
To run this test:
Run the test as a DTM job.
Fill the required data in the configuration UI that pops up when this job is scheduled.
Command syntax
Command option | Description |
---|---|
Iscsi_redirect.exe -hct -v [LogVerbosity] |
Runs the test. The -v option controls the verbosity of the logging. There are three levels of output: 0, 1, and 2. 2 is the most verbose. Default value: 1 |
Note
For command-line help for this test binary, type /h.
File list
File | Location |
---|---|
Iscsi_redirect.exe |
<[testbinroot]>\nttest\driverstest\storage\wdk\iscsi\ |
Parameters
Parameter name | Parameter description |
---|---|
LLU_NetAccessOnly | User account for accessing test fileshare. |
LLU_LclAdminUsr | User account for running the test. |
LogVerbosity | Vebosity of logging. There are three levels of output 0,1,2 where 2 is the most verbose. |