Hybrid Information Read-Write Test (LOGO)
This test validates the behavior of reads and writes to the drive with priority. There are several test cases that the drive must pass:
Being able to read and write to each priority for most of the priority
Ensuring that the optimal write granularity is being properly reported in the hybrid log
Ensuring that priority updates are updated
Ensuring that the replacement policy in the cache is sensible
Test details
Specifications |
|
Platforms |
|
Supported Releases |
|
Expected run time (in minutes) | 240 |
Category | Compatibility |
Timeout (in minutes) | 14400 |
Requires reboot | false |
Requires special configuration | false |
Type | automatic |
Additional documentation
Tests in this feature area might have additional documentation, including prerequisites, setup, and troubleshooting information, that can be found in the following topic(s):
Running the test
Before you run the test, complete the test setup as described in the test requirements: Hard Disk Drive Testing Prerequisites.
Troubleshooting
For generic troubleshooting of HLK test failures, see Troubleshooting Windows HLK Test Failures.
For troubleshooting information, see Troubleshooting Device.Storage Testing.
Hybridflt.sys must be installed for this test to work properly.
More information
The test should automatically turn the hybrid information on before checking the logs if it was not on already.
This test relies on some behavior of hybrids that are not tested in this particular test or in some test cases. Ensure that dirty data thresholds are respected.
You can use the Command Syntax section to execute a specific test case.
Command syntax
Command | Description |
---|---|
Hybriddrive.exe -drive <disk #> -scenario logrw |
Runs the test. |
-Drive <disk#> |
The drive to be tested on. The behavior of boot drives or drives with a file system is not defined. |
-Verbosity |
The logging level for this test. |
-? |
Displays help. |
-Scenario logrw |
The scenario to run. |
-case # |
The test case to run. |
Parameters
Parameter name | Parameter description |
---|---|
Verbosity | Verbosity of log output. 0 is least verbose, 4 is most verbose |
Scenario | Scenario that test targets to. |
WDKDeviceID | Instance path of device to test |
LLU_NetAccessOnly | User account for accessing test file share. |
LLU_LclAdminUsr | User account for running the test. |
StorageDriveNumber | Drive number of device to test |