Ghost Reporting

Test name

Test.GhostReporting.json

Core requirements tested

Device.Input.PrecisionTouchpad.Reliability.FalseContacts

Test purpose

Verifies that the device does not report false contacts (noise) when on AC or DC power (if applicable).

Tools required

PTLogo.exe

Validation steps

  1. Start Test.GhostReporting.json.

  2. Make sure the system connected to the device is plugged in during this iteration.

  3. Allow test to run for 60 seconds, without making any contact with the touchpad.

    Tip  

    There is a timer in the top right corner of the screen for reference.

     

  4. PTLogo.exe will automatically verify that no contacts have been reported by the device, and advance to the next iteration.

  5. the host device has battery power, unplug it and repeat steps 3-4 for the second iteration.

Common errors

None

Passing

2/2 (100%) iterations must pass in order to complete with passing status.

Precision Touchpad Tests

 

 

Send comments about this topic to Microsoft