Поделиться через


OEMTranslateIrq (Windows Embedded CE 6.0)

1/5/2010

This function translates a nonshareable IRQ into a SYSINTR or into the last shared IRQ an installable ISR does not contain.

Syntax

DWORD OEMTranslateIrq(
  DWORD Irq
);

Parameters

  • Irq
    [in] Nonshareable IRQ to translate into a SYSINTR.

Return Value

Associated SYSINTR value.

Remarks

The main ISR uses this function. This is a direct one-to-one mapping of IRQ to SYSINTR.

Requirements

Header Developer Implemented
Library Developer Implemented
Windows Embedded CE Windows CE .NET 4.0 and later

See Also

Reference

Optional OAL Functions

Other Resources

Installable ISRs and the Kernel