Detecting Project Client Version
We have heard from a lot of customers that they want to block the Project Client from connecting to the server if it does not have the latest updates to install. To solve this, you can add one of the two VBA scripts to the enterprise global to check the client version. Both solutions are not perfect, but they may help solve the problem.
The first solution looks at the file version. The only slight issue with this solution is determining the location of the Program Files directory.
Sub projVersion()
Dim MainFolderName As String
Dim LastMod As String
Dim Created As String
Dim Size As String
Dim projVersion As String
Set objShell = CreateObject("Shell.Application")
MainFolderName = "C:\Program Files\Microsoft Office\Office12"
Set FSO = CreateObject("scripting.FileSystemObject")
Set oFolder = FSO.GetFolder(MainFolderName)
'error handling to stop the obscure error that occurs at time when retrieving DateLastAccessed
On Error Resume Next
For Each fil In oFolder.Files
Set objFolder = objShell.Namespace(oFolder.Path)
Set objFolderItem = objFolder.ParseName(fil.Name)
Select Case UCase(fil.Name)
Case Is = "WINPROJ.EXE"
LastMod = fil.DateLastModified
Created = fil.DateCreated
Size = fil.Size
MsgBox ("File: " + fil.Name + " Last Modified: " + LastMod + " Created: " + Created + " Size: " + Size)
'do all of the normal tests here to determine which version you need and which you have. See above.
End Select
Next
End Sub
The second solution looks at a registry key for the Project Client version and it was written with the help of https://www.arcatapet.net/vbregget.cfm:
Const MIN_PROJ_VERSION = 6330
Const HKEY_CLASSES_ROOT = &H80000000
Const HKEY_CURRENT_USER = &H80000001
Const HKEY_LOCAL_MACHINE = &H80000002
Const HKEY_USERS = &H80000003
Const ERROR_SUCCESS = 0&
Const REG_SZ = 1& ' Unicode nul terminated string
Const REG_DWORD = 4& ' 32-bit number
Const KEY_QUERY_VALUE = &H1&
Const KEY_SET_VALUE = &H2&
Const KEY_CREATE_SUB_KEY = &H4&
Const KEY_ENUMERATE_SUB_KEYS = &H8&
Const KEY_NOTIFY = &H10&
Const KEY_CREATE_LINK = &H20&
Const READ_CONTROL = &H20000
Const WRITE_DAC = &H40000
Const WRITE_OWNER = &H80000
Const SYNCHRONIZE = &H100000
Const STANDARD_RIGHTS_REQUIRED = &HF0000 Const STANDARD_RIGHTS_READ = READ_CONTROL Const STANDARD_RIGHTS_WRITE = READ_CONTROL Const STANDARD_RIGHTS_EXECUTE = READ_CONTROL Const KEY_READ = STANDARD_RIGHTS_READ Or KEY_QUERY_VALUE Or KEY_ENUMERATE_SUB_KEYS Or KEY_NOTIFY Const KEY_WRITE = STANDARD_RIGHTS_WRITE Or KEY_SET_VALUE Or KEY_CREATE_SUB_KEY Const KEY_EXECUTE = KEY_READ
Sub ProjectVer()
Dim projVersion As String
Dim version As String
projVersion = RegGetValue$(HKEY_LOCAL_MACHINE, "Software\Microsoft\Windows\CurrentVersion\Installer\UserData\S-1-5-18\Products\00002109B30000000000000000F01FEC\InstallProperties", "DisplayVersion")
version = Mid(projVersion, 6, 4)
If (CInt(version) < MIN_PROJ_VERSION) Then
MsgBox "Your version of Winproj.exe is not valid and may cause problems." & Chr(13) & Chr(13) & _
"The installation of new version of Microsoft Project is required!" & Chr(13) & Chr(13) & _
"Required Version: " & Left(projVersion, 5) & MIN_PROJ_VERSION & ".XXXX" & (Chr(13)) & _
"Found Version: " & projVersion & Chr(13) & Chr(13) & _
"Microsoft Project will now Exit." _
, vbExclamation, "Program Version Check"
Application.FileExit pjDoNotSave
End If
End Sub
Function RegGetValue$(MainKey&, SubKey$, value$)
' MainKey must be one of the Publicly declared HKEY constants.
Dim sKeyType& 'to return the key type. This function expects REG_SZ or REG_DWORD
Dim ret& 'returned by registry functions, should be 0&
Dim lpHKey& 'return handle to opened key
Dim lpcbData& 'length of data in returned string
Dim ReturnedString$ 'returned string value
Dim ReturnedLong& 'returned long value
If MainKey >= &H80000000 And MainKey <= &H80000006 Then
' Open key
ret = RegOpenKeyExA(MainKey, SubKey, 0&, KEY_READ, lpHKey)
If ret <> ERROR_SUCCESS Then
RegGetValue = ""
Exit Function 'No key open, so leave
End If
' Set up buffer for data to be returned in.
' Adjust next value for larger buffers.
lpcbData = 255
ReturnedString = Space$(lpcbData)
' Read key
ret& = RegQueryValueExA(lpHKey, value, ByVal 0&, sKeyType, ReturnedString, lpcbData)
If ret <> ERROR_SUCCESS Then
RegGetValue = "" 'Value probably doesn't exist
Else
If sKeyType = REG_DWORD Then
ret = RegQueryValueEx(lpHKey, value, ByVal 0&, sKeyType, ReturnedLong, 4)
If ret = ERROR_SUCCESS Then RegGetValue = CStr(ReturnedLong)
Else
RegGetValue = Left$(ReturnedString, lpcbData - 1)
End If
End If
' Always close opened keys.
ret = RegCloseKey(lpHKey)
End If
End Function
Comments
- Anonymous
February 04, 2009
I'm interested in implementing this but I don't know how to add the code to the Enterprise Global. I have some experience with writing VBScript against COM objects. If you can point me in the right direction I should be able to figure things out. Thank you!!