Partilhar via


SMS_UpdatesAssignment Server WMI Class

Applies To: System Center Configuration Manager 2007, System Center Configuration Manager 2007 R2, System Center Configuration Manager 2007 R3, System Center Configuration Manager 2007 SP1, System Center Configuration Manager 2007 SP2

The SMS_UpdatesAssignment Windows Management Instrumentation (WMI) class is an SMS Provider server class, in Configuration Manager, that represents a deployment.

The following syntax is simplified from Managed Object Format (MOF) code and includes all inherited properties.

Class SMS_UpdatesAssignment : SMS_CIAssignmentBaseClass
{
      Boolean ApplyToSubTargets;
      SInt32 AssignedCIs[];
      SInt32 AssignmentAction;
      String AssignmentDescription;
      SInt32 AssignmentID;
      String AssignmentName;
      String AssignmentUniqueID;
      Boolean ContainsExpiredUpdates;
      DateTime CreationTime;
      SInt32 DesiredConfigType;
      Boolean DisableMomAlerts;
      UInt32 DPLocality;
      DateTime EnforcementDeadline;
      String EvaluationSchedule;
      DateTime ExpirationTime;
      DateTime LastModificationTime;
      UInt32 LegacyAdvertFlags;
      Boolean LegacyCollectInventory;
      String LegacyDependentProgram;
      Boolean LegacyDeploymentEnabled;
      String LegacyDeploymentSchedule;
      UInt32 LegacyDPLocality;
      Boolean LegacyForceReboot;
      Boolean LegacyInstallAllOnDeadline;
      SInt32 LegacyInstallAllowedWindow;
      Boolean LegacyPostponeInstall;
      UInt32 LegacyProgramFlags;
      UInt32 LegacyRebootCountdown;
      Boolean LegacySilentInstall;
      UInt32 LocaleID;
      Boolean LogComplianceToWinEvent;
      SInt32 NonComplianceCriticality;
      Boolean NotifyUser;
      Boolean OverrideServiceWindows;
      Boolean RaiseMomAlertsOnFailure;
      Boolean ReadOnly;
      Boolean RebootOutsideOfServiceWindows;
      Boolean SendDetailedNonComplianceStatus;
      String SourceSite;
      DateTime StartTime;
      UInt32 SuppressReboot;
      String TargetCollectionID;
      Boolean UseGMTTimes;
      Boolean WoLEnabled;
};

Methods

The SMS_UpdatesAssignment class does not define any methods.

Properties

  • DPLocality
    Data type: UInt32

    Access type: Read/Write

    Qualifiers: [not_null, bits]

    See SMS_CIAssignmentBaseClass Server WMI Class.

    For this class, the DPLocality property defaults to the flag combination DP_DOWNLOAD_FROM_LOCAL | DP_DOWNLOAD_FROM_REMOTE (0x50).

  • EnforcementDeadline
    Data type: DateTime

    Access type: Read/Write

    Qualifiers: None

    The date and time to automatically install the software update. Set this property to zero if the update is optional. It must not be set to a null pointer.

  • LegacyAdvertFlags
    Data type: UInt32

    Access type: Read/Write

    Qualifiers: [bits]

    Flags indicating how the advertisement should be announced to the user of SMS 2003. Possible values are:

    Bit Description

    5

    IMMEDIATE

    8

    ONSYSTEMSTARTUP

    9

    ONUSERLOGON

    10

    ONUSERLOGOFF

    These flags must be coordinated with the flags specified in the ProgramFlags property of the advertised program. For example, if you set ONUSERLOGOFF, the NOUSERLOGGEDIN flag in the program must be set. If the flag settings do not match, the program is not advertised. For more information, see SMS_Program Server WMI Class.

    Setting IMMEDIATE, ONUSERLOGON, or ONUSERLOGOFF or providing an AssignedSchedule value makes the advertised program mandatory. A mandatory program is run automatically after the client has received the advertisement. The client cannot reject or postpone the installation.

  • LegacyCollectInventory
    Data type: Boolean

    Access type: Read/Write

    Qualifiers: [lazy]

    true to trigger the inventory collection on SMS 2003. The default value is false.

  • LegacyDependentProgram
    Data type: String

    Access type: Read/Write

    Qualifiers: None

    Formatted text string defining any program that should be run prior to the current program on SMS 2003. The default value is "".

    The format for this property is defined as <PackageID>;;<ProgramName>. If the program is in the same package, simply specify ;;<ProgramName>.

    The dependency is maintained only the first time that the program runs. After the program has run, the dependency is ignored. For example, you cannot create a recurring scheduled job for which the dependency is maintained for each program run.

  • LegacyDeploymentEnabled
    Data type: Boolean

    Access type: Read/Write

    Qualifiers: [not_null]

    true if the software updates deployment is enabled for SMS 2003 clients.

  • LegacyDeploymentSchedule
    Data type: String

    Access type: Read/Write

    Qualifiers: [lazy]

    Advertisement schedule for SMS 2003 clients.

  • LegacyDPLocality
    Data type: UInt32

    Access type: Read/Write

    Qualifiers: [lazy, bits]

    Flags that determine how the SMS 2003 client obtains content from distribution points, according to distribution point locality. Possible values are shown below. The default value is DP_RUN_FROM_LOCAL | DP_RUN_FROM_REMOTE (bits 3 and 7 or 0x88).

    Bit Description

    3

    DP_RUN_FROM_LOCAL

    4

    DP_DOWNOLAD_FROM_LOCAL

    5

    DP_NO_REMOTE

    6

    DP_DOWNLOAD_FROM_REMOTE

    7

    DP_RUN_FROM_REMOTE

    17

    DP_NO_FALLBACK_UNPROTECTED

  • LegacyForceReboot
    Data type: Boolean

    Access type: Read/Write

    Qualifiers: [lazy]

    true (default) to force reboot for SMS 2003 clients, if required.

  • LegacyInstallAllOnDeadline
    Data type: Boolean

    Access type: Read/Write

    Qualifiers: [lazy]

    true (default) to install on SMS 2003 clients only the updates that meet the deadline.

  • LegacyInstallAllowedWindow
    Data type: SInt32

    Access type: Read/Write

    Qualifiers: [lazy]

    Install window for updates on SMS 2003 clients.

  • LegacyPostponeInstall
    Data type: Boolean

    Access type: Read/Write

    Qualifiers: [lazy]

    true (default) to enable postponement of SMS 2003 installations.

    Maps to /P.

  • LegacyProgramFlags
    Data type: UInt32

    Access type: Read/Write

    Qualifiers: [bits]

    Flags defining the installation characteristics of the program for SMS 2003. Possible values are listed below. The default value is COUNTDOWN(10).

    Bit Description

    7

    DEPENDANT_FORCE_RERUN

    9

    RUN_DEPENDANT_ALWAYS

    10

    COUNTDOWN

  • LegacyRebootCountdown
    Data type: UInt32

    Access type: Read/Write

    Qualifiers: [not_null]

    Reboot countdown for SMS 2003. The default value is 0.

  • LegacySilentInstall
    Data type: Boolean

    Access type: Read/Write

    Qualifiers: [lazy]

    true for a silent installation for SMS 2003. The default value is false.

  • ReadOnly
    Data type: Boolean

    Access type: Read-only

    Qualifiers: [read, not_null]

    The assignment is read-only.

Remarks

Class qualifiers for this class include:

  • Secured

For more information about both the class qualifiers and the property qualifiers included in the Properties section, see Configuration Manager Class and Property Qualifiers.

After preparing the software updates to deploy, your application can use this class as described in How to Configure and Deploy Updates. After the application creates the deployment, Configuration Manager creates the corresponding policy in the database. The client polls the management point for new and changed properties and the download occurs when a request is detected.

Requirements

Runtime Requirements

For more information, see Configuration Manager Server Runtime Requirements.

Development Requirements

For more information, see Configuration Manager Server Development Requirements.

See Also

Concepts

Software Updates Server WMI Classes
Configuration Manager Software Updates
How to Configure and Deploy Updates