Editar

Partilhar via


Converting Data Types from z/OS COBOL to Automation

Use the tables in this topic as a guide when you set up the way you want Transaction Integrator (TI) to handle conversions from COBOL data types to Automation data types. For more information about the specific data types, see Supported TI Data Types.

Use the following code key to interpret the codes in the Possible Conversion Errors and Required Property Settings columns in each table.

Code Description
r Range errors possible.
b Possible loss of precision due to base 2 to base 16 conversion.
p Possible loss of precision due to picture format scale specification.
m Mapping errors possible.
f yyyyddd and hhmmss.
A You must specify Truncate, Round, or Error under Error handling on the COBOL Definition tab of the property page.
C You must specify the precision and scale by filling in the Digits left and Digits right boxes on the COBOL Definition tab of the property page.
D You must specify the string width by filling in the Size box on the COBOL Definition tab of the property page.
E Unicode or EBCDIC mapping information is required, such as a code page.
F For arrays whose length is less than the maximum specified, you must specify Size of Filler under Trailing filler on the COBOL Definition tab of the property page.
G You must specify how strings should be dealt with. Click Space Padded or Null terminated under String Delimiting on the COBOL Definition tab of the property page. Then click Truncate or Error under Error handling on the COBOL Definition tab of the property page to specify what TI should do if the string is too long.
H Maximum size is required.
I Localization is required.
J Optional SO and SI insertion and deletion is supported.

The following table shows the defaults that TI uses when you import COBOL source code.

Default

From z/OS COBOL data type To Automation data type Possible conversion errors Required property settings
COMP-1 4-byte Real (Single) b,r None
COMP-2 8-byte Real (Double) b,r None
COMP-3 Packed Decimal Currency p AC
COMP-3 Packed Decimal Decimal p AC
DATE and TIME Date None I
TIME only Date None I
DATE only Date None I
PIC X Variable-length String m DEG
PIC X No Translation 1-byte unsigned Integer None None
PIC S9(4) COMP (Integer 16-bit) 2-byte signed Integer None None
PIC S9(4) COMP (Integer 16-bit) Boolean None None
PIC S9(9) COMP (Integer 32-bit) 4-byte signed Integer None None
OCCURS fixed TIMES Array None None

Note

When you convert fractional numbers from Packed Decimal or distributed program call (DPC) Zoned Decimal data types, you should convert to Visual Basic Decimal data type.

For COMP, COMP-3, and DISPLAY numeric COBOL data types, the default is based on the precision and scale shown in the following table. When COBOL uses DISPLAY without a sign and you change the Automation type to String, the COBOL picture is changed to PIC X, which has the same internal data representation. The length remains the same and therefore does not affect your mainframe program.

Precision and scale for z/OS COBOL To Automation data type
Precision 1-4, scale 0 2-byte signed Integer
Precision 5-9, scale 0 4-byte signed Integer
Precision 5-7, scale 3-7 4-byte Real
Precision 8-18, scale 3-18 8-byte Real
Precision 1-18, scale 1-2 Currency
Precision 10-18, scale 0 Decimal

The following table shows the other supported data type mappings that you can set in TI Project to override the defaults presented previously in this topic.

Supported in Transaction Integrator

From z/OS COBOL data type To Automation data type Possible conversion errors Required property settings
COMP-1 Array None None
COMP-2 Array None None
COMP-3 Packed Decimal 2-byte signed Integer p,r AC
COMP-3 Packed Decimal 4-byte signed Integer p,r AC
COMP-3 Packed Decimal 4-byte Real (Single) p,r AC
COMP-3 Packed Decimal 8-byte Real (Double) p C
COMP-3 Packed Decimal Boolean None None
COMP-3 Packed Decimal 1-byte unsigned Integer r None
COMP-3 Packed Decimal Array None None
DISPLAY Zoned Decimal 2-byte signed Integer p,r AC
DISPLAY Zoned Decimal 4-byte Real (Single) p,r AC
DISPLAY Zoned Decimal 8-byte Real (Double) p,r AC
DISPLAY Zoned Decimal Currency p,r AC
DISPLAY Zoned Decimal Decimal p,r AC
DATE and TIME Array None None
TIME only Array None None
DATE only Array None None
PIC X Array None None
PIC X No Translation Array None None
PIC G Variable-length String m DEGJ
PIC G Array None None
PIC S9(4) COMP (Integer 16-bit) 1-byte unsigned Integer r None
PIC S9(4) COMP (Integer 16-bit) Array None None
PIC S9(9) COMP (Integer 32-bit) Boolean None None
PIC S9(9) COMP (Integer 32-bit) 1-byte unsigned Integer r None
PIC S9(9) COMP (Integer 32-bit) Array None None
PIC S9(?)V9(?) COMP (16-bit) 4-byte Real (Single) p,r None
PIC S9(?)V9(?) COMP (16-bit) 8-byte Real (Double) p,r None
PIC S9(?)V9(?) COMP (16-bit) Currency p,r None
PIC S9(?)V9(?) COMP (16-bit) Decimal p,r None
PIC S9(?)V9(?) COMP (32-bit) 4-byte Real (Single) p,r None
PIC S9(?)V9(?) COMP (32-bit) 8-byte Real (Double) p,r None
PIC S9(?)V9(?) COMP (32-bit) Currency p,r None
PIC S9(?)V9(?) COMP (32-bit) Decimal p,r None
OCCURS DEPENDING ON Array None None

Note

When you convert fractional numbers from Packed Decimal or DPC Zoned Decimal data types, you should convert to Visual Basic Decimal data type.

The following table shows additional supported data type mappings that the TI run-time environment supports.

Supported only by the TI run-time environment

From z/OS COBOL data type To Automation data type Possible conversion errors Required property settings
DISPLAY Zoned Decimal 1-byte unsigned Integer None AC
DISPLAY Zoned Decimal 4-byte signed Integer None AC
DISPLAY Zoned Decimal Boolean None AC

No other data type conversions from COBOL to Automation are supported by TI at this time.

See Also

Supported TI Data Types
Converting Data Types from Automation to z/OS COBOL]
Data Type Conversion