How to Configure the Send Shape

Image that represents the Send shape.
Send shape

If you expect to receive an indirect or asynchronous response (not using a request-response port) to the message that you have sent, you need to correlate the message with the currently running instance of the orchestration, so that the respondent can get the response to the correct instance. You can apply a following correlation set to the Send shape for a previously initialized correlation, or you can apply an initializing correlation set. For more information, see Using Correlations in Orchestrations.

To configure a Send shape

  1. Set a message and a port operation.

    1. In the Orchestration View window, verify that your orchestration has both a message and a port operation defined for the multi-part message type being sent.

    2. In the Properties window, select the message to send from the Message property drop-down list.

    3. In the Properties window, select the port operation that sends the message from the Port Operation drop-down list.

      —Or—

      Drag the send connector from the Send shape to the port socket that sends the message.

  2. Specify correlation sets to restrict the messages the Send shape will send or to initialize the values in a correlation set.

    1. For each correlation set you want to use, check a correlation set from the drop-down on the Following Correlation Sets property.

    2. For each correlation set that you want to initialize, check a correlation set from the drop-down on the Initializing Correlation Sets property.

Delivery Notification

To test whether you have successfully sent a message over a send port, complete the following steps:

  1. Put your Send shape in a non-transactional, long-running or atomic scope.

  2. On your send port, set the DeliveryNotification property to Transmitted.

  3. Add a catch handler to your scope to handle a DeliveryFailureException.

    Note

    If the Send shape is contained within an atomic scope, the DeliveryFailureException can still be caught, but will require an outer scope shape be added with a Transaction Type set to Long Running or None. Atomic scopes are not able to catch exceptions directly.

    The orchestration waits for acknowledgment at the end of the enclosing non-atomic scope, or the end of the orchestration, to receive the acknowledgment.

Note

This applies only to one-way operations; failure in two-way (request-response) operations results in a SoapException (negative acknowledgement) even without the port attribute being set.

Note

Delivery notification is not supported for direct binding.