Windows Filtering Platform (WFP) specific error codes are as follows.

WFP error constant / value

Description

FWP_E_CALLOUT_NOT_FOUND

0x80320001

The callout does not exist.

FWP_E_CONDITION_NOT_FOUND

0x80320002

The filter condition does not exist.

FWP_E_FILTER_NOT_FOUND

0x80320003

The filter does not exist.

FWP_E_LAYER_NOT_FOUND

0x80320004

The layer does not exist.

FWP_E_PROVIDER_NOT_FOUND

0x80320005

The provider does not exist.

FWP_E_PROVIDER_CONTEXT_NOT_FOUND

0x80320006

The provider context does not exist.

FWP_E_SUBLAYER_NOT_FOUND

0x80320007

The sub-layer does not exist.

FWP_E_NOT_FOUND

0x80320008

The object does not exist.

The IPsecSaContext* functions return this error if the SA context ID is not found.

FWP_E_ALREADY_EXISTS

0x80320009

An object with that GUID or LUID already exists.

FWP_E_IN_USE

0x8032000A

The object is referenced by other objects, so it cannot be deleted.

FWP_E_DYNAMIC_SESSION_IN_PROGRESS

0x8032000B

The call is not allowed from within a dynamic session.

FWP_E_WRONG_SESSION

0x8032000C

The call was made from the wrong session, so it cannot be completed.

FWP_E_NO_TXN_IN_PROGRESS

0x8032000D

The call must be made from within an explicit transaction.

FWP_E_TXN_IN_PROGRESS

0x8032000E

The call is not allowed from within an explicit transaction.

FWP_E_TXN_ABORTED

0x8032000F

The explicit transaction has been forcibly cancelled.

FWP_E_SESSION_ABORTED

0x80320010

The session has been cancelled.

The session handle needs to be closed by calling FwpmEngineClose0, even though it is no longer valid; otherwise, the client-side state will be leaked. A new session should be created by calling FwpmEngineOpen0.

FWP_E_INCOMPATIBLE_TXN

0x80320011

The call is not allowed from within a read-only transaction.

FWP_E_TIMEOUT

0x80320012

The call timed out while waiting to acquire the transaction lock.

FWP_E_NET_EVENTS_DISABLED

0x80320013

The collection of network diagnostic events is disabled.

FWP_E_INCOMPATIBLE_LAYER

0x80320014

The operation is not supported by the specified layer.

FWP_E_KM_CLIENTS_ONLY

0x80320015

The call is allowed for kernel-mode callers only.

FWP_E_LIFETIME_MISMATCH

0x80320016

The call tried to associate two objects with incompatible lifetimes.

FWP_E_BUILTIN_OBJECT

0x80320017

The object is built-in, so it cannot be deleted.

FWP_E_TOO_MANY_CALLOUTS

0x80320018

The maximum number of callouts has been reached.

At most, 100,000 callouts can be registered at the same time.

FWP_E_NOTIFICATION_DROPPED

0x80320019

A notification could not be delivered because a message queue is at its maximum capacity.

FWP_E_TRAFFIC_MISMATCH

0x8032001A

The network traffic parameters do not match those for the security association context.

IPsecSaContextGetSpi0 can be called multiple times, but the caller must specify the same IPSEC_TRAFFIC0 each time. This error is returned if a subsequent call supplies a different IPSEC_TRAFFIC0.

FWP_E_INCOMPATIBLE_SA_STATE

0x8032001B

The call is not allowed for the current security association (SA) state.

The SA context functions must be called in a specific order:

This error is returned if they are called out of order.

FWP_E_NULL_POINTER

0x8032001C

A required pointer is null.

FWP_E_INVALID_ENUMERATOR

0x8032001D

An enumerator value in a structure is out of range.

FWP_E_INVALID_FLAGS

0x8032001E

The flags field contains an invalid value.

FWP_E_INVALID_NET_MASK

0x8032001F

A network mask is not valid.

FWP_E_INVALID_RANGE

0x80320020

An FWP_RANGE0 structure is not valid.

FWP_E_INVALID_INTERVAL

0x80320021

The time interval is not valid.

FWP_E_ZERO_LENGTH_ARRAY

0x80320022

An array that must contain at least one element has zero length.

FWP_E_NULL_DISPLAY_NAME

0x80320023

The displayData.name field cannot be null.

FWP_E_INVALID_ACTION_TYPE

0x80320024

The action type is not one of the allowed action types for a filter.

FWP_E_INVALID_WEIGHT

0x80320025

The filter weight is not valid.

FWP_E_MATCH_TYPE_MISMATCH

0x80320026

A filter condition contains a match type that is not compatible with the operands.

See topic FWP_MATCH_TYPE for more information.

FWP_E_TYPE_MISMATCH

0x80320027

An FWP_VALUE0 structure or an FWP_CONDITION_VALUE0 structure is of the wrong type.

FWP_E_OUT_OF_BOUNDS

0x80320028

An integer value is outside the allowed range.

FWP_E_RESERVED

0x80320029

A reserved field is non-zero.

FWP_E_DUPLICATE_CONDITION

0x8032002A

A filter cannot contain multiple conditions operating on a single field.

FWP_E_DUPLICATE_KEYMOD

0x8032002B

A policy cannot contain the same keying module more than once.

FWP_E_ACTION_INCOMPATIBLE_WITH_LAYER

0x8032002C

The action type is not compatible with the layer.

FWP_E_ACTION_INCOMPATIBLE_WITH_SUBLAYER

0x8032002D

The action type is not compatible with the sub-layer.

FWP_E_CONTEXT_INCOMPATIBLE_WITH_LAYER

0x8032002E

The raw context or the provider context is not compatible with the layer.

FWP_E_CONTEXT_INCOMPATIBLE_WITH_CALLOUT

0x8032002F

The raw context or the provider context is not compatible with the callout.

FWP_E_INCOMPATIBLE_AUTH_METHOD

0x80320030

The authentication method is not compatible with the policy type.

FWP_E_INCOMPATIBLE_DH_GROUP

0x80320031L

The Diffie-Hellman group is not compatible with the policy type.

FWP_E_EM_NOT_SUPPORTED

0x80320032

An IKE policy cannot contain an Extended Mode policy.

FWP_E_NEVER_MATCH

0x80320033

The enumeration template or subscription will never match any objects.

FWP_E_PROVIDER_CONTEXT_MISMATCH

0x80320034

The provider context is of the wrong type.

FWP_E_INVALID_PARAMETER

0x80320035

The parameter is incorrect.

Possible reasons for this error:

  • FwpmIPsecTunnelAdd0 was called without setting the flag FWPM_TUNNEL_FLAG_POINT_TO_POINT and with conditions other than local/remote address.
  • An invalid Unicode string, or a Unicode string that contains unprintable characters.

FWP_E_TOO_MANY_SUBLAYERS

0x80320036

The maximum number of sub-layers has been reached.

WFP supports at most 216 sub-layers.

FWP_E_CALLOUT_NOTIFICATION_FAILED

0x80320037

The notification function for a callout returned an error.

FWP_E_INVALID_AUTH_TRANSFORM

0x80320038

The IPsec authentication transform is not valid.

FWP_E_INVALID_CIPHER_TRANSFORM

0x80320039

The IPsec cipher transform is not valid.

See Also

Reference

WFP Constants
WFP Access Right Identifiers
WFP Built-in Callout Identifiers
WFP Built-in Keying Module Identifiers
WFP Built-in Provider Context Identifiers
WFP Built-in Provider Identifiers
WFP Filter Context Identifiers
WFP Filter Weight Identifiers
WFP Filtering Conditions
WFP Filtering Layer Identifiers
WFP Filtering Sublayer Identifiers

Other Resources

Windows Filtering Platform