CIM_TransparentBridgingService class

Represents the transparent bridging aspect of a CIM_SwitchService object.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.

Syntax

[Abstract, Version("2.7.0"), AMENDMENT]
class CIM_TransparentBridgingService : CIM_ForwardingService
{
  string   Caption;
  string   Description;
  string   ElementName;
  datetime InstallDate;
  uint16   OperationalStatus[];
  string   StatusDescriptions[];
  string   Status;
  uint16   HealthState;
  uint16   EnabledState = 5;
  string   OtherEnabledState;
  uint16   RequestedState = 12;
  uint16   EnabledDefault = 2;
  datetime TimeOfLastStateChange;
  string   SystemCreationClassName;
  string   SystemName;
  string   CreationClassName;
  string   Name;
  string   PrimaryOwnerName;
  string   PrimaryOwnerContact;
  string   StartMode;
  boolean  Started;
  string   Keywords[];
  string   ServiceURL;
  string   StartupConditions[];
  string   StartupParameters[];
  uint16   ProtocolType;
  string   OtherProtocolType;
  uint32   AgingTime = 300;
  uint32   FID;
};

Members

The CIM_TransparentBridgingService class has these types of members:

Methods

The CIM_TransparentBridgingService class has these methods.

Method Description
RequestStateChange Requests that the state of the element be changed to the specified value.
This method is inherited from CIM_EnabledLogicalElement.
StartService Starts the service.
This method is inherited from CIM_Service.
StopService Stops the service.
This method is inherited from CIM_Service.

Properties

The CIM_TransparentBridgingService class has these properties.

AgingTime

Data type: uint32

Access type: Read-only

Qualifiers: Units ("Seconds"), MappingStrings ("MIB.IETF|BRIDGE-MIB.dot1dTpAgingTime")

The timeout period, in seconds, for aging out dynamically learned forwarding information. The 802.1D-1990 standard recommends a default of 300 seconds.

Caption

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

A short textual description of the object.

This property is inherited from CIM_ManagedElement.

CreationClassName

Data type: string

Access type: Read-only

Qualifiers: Key, MaxLen (256)

The class name used to create an instance of this class. CreationClassName is combined with other key properties of this class to uniquely identify instances of this class and its subclasses.

This property is inherited from CIM_Service.

Description

Data type: string

Access type: Read-only

A textual description of the object.

This property is inherited from CIM_ManagedElement.

ElementName

Data type: string

Access type: Read-only

A user-friendly name for the object. This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information.

This property is inherited from CIM_ManagedElement.

EnabledDefault

Data type: uint16

Access type: Read/write

Indicates an administrator's default or startup configuration for the enabled state of an element. The default value Enabled (2).

This property is inherited from CIM_EnabledLogicalElement.

The possible values are.

Enabled (2)

Disabled (3)

Not Applicable (5)

Enabled but Offline (6)

No Default (7)

Quiesce (9)

DMTF Reserved

10 32767

Vendor Reserved

32768 65535

EnabledState

Data type: uint16

Access type: Read-only

Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.OtherEnabledState")

Indicates the enabled state of an element. Possible values include the transitions between states. For example, Shutting Down (4) and Starting (10) are transient states between Enabled and Disabled.

This property is inherited from CIM_EnabledLogicalElement.

The possible values are.

Unknown (0)

Indicates that the state of the element is unknown.

Other (1)

Indicates that the state of the element is described in the OtherEnabledState property.

Enabled (2)

Indicates that the element executes or could execute commands, processes any queued commands, and queues new requests.

Disabled (3)

Indicates that the element does not execute commands and that it drops any new requests.

Shutting Down (4)

Indicates that the element is in the process of changing to a Disabled state.

Not Applicable (5)

Indicates the element does not support to be enabled or disabled.

Enabled but Offline (6)

Indicates that the element might be completing commands and that it drops any new requests.

In Test (7)

Indicates that the element is in a test state.

Deferred (8)

Indicates that the element might be completing commands, but that it queues any new requests.

Quiesce (9)

Indicates that the element is enabled but is in a restricted mode.

Starting (10)

Indicates that the element is in the process of changing to an Enabled state. New requests are queued.

DMTF Reserved

Reserved.

Vendor Reserved

Reserved.

FID

Data type: uint32

Access type: Read-only

Filtering Database Identifier used by VLAN-aware switches that have more than one filtering database.

HealthState

Data type: uint16

Access type: Read-only

Indicates the current health of the element. This attribute expresses the health of this element, but not necessarily the health of its subcomponents.

This property is inherited from CIM_ManagedSystemElement.

Unknown (0)

The implementation cannot report on HealthState at this time.

OK (5)

The element is fully functional and operates within normal operational parameters and without error.

Degraded/Warning (10)

The element is in working order, and all functionality is provided. However, the element does not function to the best of its abilities. For example, the element might not operate at optimal performance, or it might report recoverable errors.

Minor failure (15)

All functionality is available, but some functionality might be degraded.

Major failure (20)

The element is failing. It is possible that some or all of the functionality of this component is degraded or does not work.

Critical failure (25)

The element is nonfunctional, and recovery might not be possible.

Non-recoverable error (30)

The element has completely failed, and recovery is not possible. All functionality that this element provides has been lost.

DMTF Reserved

Reserved.

InstallDate

Data type: datetime

Access type: Read-only

Qualifiers: MappingStrings ("MIF.DMTF|ComponentID|001.5")

Indicates when the object was installed. The lack of a value does not indicate that the object is not installed.

This property is inherited from CIM_ManagedSystemElement.

Keywords

Data type: string array

Access type: Read-only

Qualifiers: Deprecated ("No value")

This property is deprecated and should not be used.

Note

Deprecated description: An array of keywords that can be used in queries.

This property is inherited from CIM_NetworkService.

Name

Data type: string

Access type: Read-only

Qualifiers: Key, MaxLen (256)

A unique identifier of the service that indicates the functionality of the service.

This property is inherited from CIM_Service.

OperationalStatus

Data type: uint16 array

Access type: Read-only

Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.StatusDescriptions")

Contains indicators of the current status of the element. The first value of the OperationalStatus property should contain the primary status for the element.

Note

The OperationalStatus property replaces the deprecated Status property. Due to the widespread use of the existing Status property in management applications, we strongly recommend that providers or instrumentation provide both the Status and OperationalStatus properties. When instrumented, Status, because it is a single-valued property, should also provide the primary status of the element.

This property is inherited from CIM_ManagedSystemElement.

The possible values are.

Unknown (0)

Indicates that the implementation cannot report on the OperationalStatus property at this time.

Other (1)

Indicates an undefined state.

OK (2)

Indicates full functionality without errors.

Degraded (3)

Indicates that the element is in working order and that all functionality is provided. However, the element does not function to the best of its abilities. For example, the element might not operate at optimal performance, or it might report recoverable errors.

Stressed (4)

Indicates that the element functions, but requires attention. Overload and overheated are examples of Stressed states.

Predictive Failure (5)

Indicates that an element functions nominally, but predicts a failure in the near future.

Error (6)

Indicates that an error has occurred.

Non-Recoverable Error (7)

Indicates that a nonrecoverable error has occurred.

Starting (8)

Indicates that the job is starting.

Stopping (9)

Indicates that the job is stopping.

Stopped (10)

Indicates that the element has been intentionally stopped.

In Service (11)

Indicates that the element is in process to be configured, maintained, cleaned, or otherwise administered.

No Contact (12)

Indicates that the monitoring system has information about this element, but has never been able to establish communications with it.

Lost Communication (13)

Indicates that the monitoring system has successfully contacted this element in the past, but it is currently unavailable.

Aborted (14)

Indicates that the job stopped in an unexpected way. The state and configuration of the job might require an update.

Dormant (15)

Indicates that the job is inactive.

Supporting Entity in Error (16)

Indicates that an element on which this job depends is in error. This element might be OK but cannot function because of the state of a dependent element. An example is a network service or endpoint that cannot function due to lower-layer networking problems.

Completed (17)

Indicates that the job has completed its operation. This value should be combined with either OK, Error, or Degraded to indicate to a client whether the complete operation Completed with OK and passed, or completed with Error and failed, or completed with Degraded and finished the operation, but did not complete OK or did not report an error.

Power Mode (18)

Indicates that the element has additional power model information that is contained in the associated power management service.

DMTF Reserved

Reserved.

Vendor Reserved

Reserved.

OtherEnabledState

Data type: string

Access type: Read-only

Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")

Describes the state of the element when the value of the EnabledState property is Other. This property must be set to NULL when EnabledState is not Other.

This property is inherited from CIM_EnabledLogicalElement.

OtherProtocolType

Data type: string

Access type: Read-only

Qualifiers: MaxLen (32), ModelCorrespondence ("CIM_ForwardingService.ProtocolType")

Defines the type of protocol to forward when the value of the ProtocolType property is 1 (Other).

This property is inherited from CIM_ForwardingService.

PrimaryOwnerContact

Data type: string

Access type: Read/write

Qualifiers: MaxLen (256), MappingStrings ("MIF.DMTF|General Information|001.4")

Contact information for the primary owner of the service.

This property is inherited from CIM_Service.

PrimaryOwnerName

Data type: string

Access type: Read/write

Qualifiers: MaxLen (64), MappingStrings ("MIF.DMTF|General Information|001.3")

The name of the primary owner of the service.

This property is inherited from CIM_Service.

ProtocolType

Data type: uint16

Access type: Read-only

Qualifiers: ModelCorrespondence ("CIM_ForwardingService.OtherProtocolType")

The type of protocol to forward.

This property is inherited from CIM_ForwardingService.

Unknown (0)

Other (1)

IPv4 (2)

IPv6 (3)

IPv4/IPv6 (4)

IPX (5)

AppleTalk (6)

DECnet (7)

SNA (8)

CONP (9)

CLNP (10)

VINES (11)

XNS (12)

ATM (13)

Frame Relay (14)

Ethernet (15)

TokenRing (16)

FDDI (17)

Infiniband (18)

Fibre Channel (19)

RequestedState

Data type: uint16

Access type: Read-only

Qualifiers: ModelCorrespondence ("CIM_EnabledLogicalElement.EnabledState")

Indicates the last requested state for the element. The current state is indicated by the EnabledState property. This property enables you to compare the last requested and current states.

Note

When the value of the EnabledState property is Not Applicable, this property has no meaning.

This property is inherited from CIM_EnabledLogicalElement.

The possible values are.

Unknown (0)

Indicates the last requested state for the element is unknown.

Enabled (2)

Indicates that the element executes or could execute commands, processes any queued commands, and queues new requests.

Disabled (3)

Indicates a request to immediately disable the element, such that it does not execute or accept any commands or processing requests.

Shut Down (4)

Indicates a request for an orderly transition to the Disabled state, and might require you to shut off the power to completely erase any existing state.

No Change (5)

No state change has been requested.

Offline (6)

Indicates a request to change to the Enabled but Offline state.

Test (7)

Indicates that the element is in a test state.

Deferred (8)

Indicates that the element might be completing commands, but that it queues any new requests.

Quiesce (9)

Indicates that the element is enabled but is in a restricted mode.

Reboot (10)

Indicates a request to shut down and then change to an Enabled state.

Reset (11)

Indicates a request to change to a Disabled state and then change to an Enabled state.

Not Applicable (12)

Indicates that this instance does not support the RequestedState property.

DMTF Reserved

Reserved.

Vendor Reserved

Reserved.

ServiceURL

Data type: string

Access type: Read-only

Qualifiers: Deprecated ("CIM_ServiceAccessURI")

This property is deprecated. Instead, we recommend the CIM_ServiceAccessURI class.

Note

Deprecated description: A URL that provides the protocol, network location, and other service-specific information required in order to access the service.

This property is inherited from CIM_NetworkService.

Started

Data type: boolean

Access type: Read-only

true if the service has been started; otherwise, false.

This property is inherited from CIM_Service.

StartMode

Data type: string

Access type: Read-only

Qualifiers: Deprecated ("CIM_Service.EnabledDefault"), MaxLen (10)

This property is deprecated. Instead, use the EnabledDefault property that is inherited from CIM_EnabledLogicalElement.

Note

Deprecated description: Indicates whether the service is automatically started (for example, by an operating system) or only started upon request.

This property is inherited from CIM_Service.

StartupConditions

Data type: string array

Access type: Read-only

Qualifiers: Deprecated ("No value")

This property is deprecated and should not be used.

Note

Deprecated description: The pre-conditions that must be met in order for this service to start correctly.

This property is inherited from CIM_NetworkService.

StartupParameters

Data type: string array

Access type: Read-only

Qualifiers: Deprecated ("No value")

This property is deprecated and should not be used.

Note

Deprecated description: The parameters that must be supplied to the StartService method in order for this service to start correctly.

This property is inherited from CIM_NetworkService.

Status

Data type: string

Access type: Read-only

Qualifiers: Deprecated ("CIM_ManagedSystemElement.OperationalStatus"), MaxLen (10)

Indicates the primary status of the object.

Note

This property is deprecated. It is replaced by the OperationalStatus property. If you choose to use the Status property for backward compatibility, it should be secondary to the OperationalStatus property.

This property is inherited from CIM_ManagedSystemElement.

StatusDescriptions

Data type: string array

Access type: Read-only

Qualifiers: ArrayType ("Indexed"), ModelCorrespondence ("CIM_ManagedSystemElement.OperationalStatus")

Indicates descriptions of the corresponding values in the OperationalStatus array. For example, if an element in the OperationalStatus property contains the value Stopping, then the element at the same array index in this property might contain an explanation as to why an object is being stopped.

This property is inherited from CIM_ManagedSystemElement.

SystemCreationClassName

Data type: string

Access type: Read-only

Qualifiers: Key, Propagated ("CIM_System.CreationClassName"), MaxLen (256)

The class name used to create an instance of the system that contains the service. SystemCreationClassName is combined with other key properties of this class to uniquely identify instances of this class and its subclasses.

This property is inherited from CIM_Service.

SystemName

Data type: string

Access type: Read-only

Qualifiers: Key, Propagated ("CIM_System.Name"), MaxLen (256)

The name of the scoping system.

This property is inherited from CIM_Service.

TimeOfLastStateChange

Data type: datetime

Access type: Read-only

Indicates when the element last changed state. If the state of the element has not changed and this property is populated, then it must be set to a zero interval value. If a state change was requested, but was rejected or is not yet processed, the property must not be updated.

This property is inherited from CIM_EnabledLogicalElement.

Requirements

Minimum supported client
None supported
Minimum supported server
Windows Server 2008
End of client support
None supported
End of server support
Windows Server 2012 R2
Namespace
Root\virtualization
MOF
WindowsVirtualization.mof

See also