Compartilhar via


MSFT_MTLogicalProcessor class

The Logical Processor data object. Statistic data is calculated based on current interval seconds setting.

The following syntax is simplified from Managed Object Format (MOF) code and includes all of the inherited properties.

Syntax

[UMLPackagePath("CIM::Core::CoreElements"), dynamic, provider("mttmprov"), AMENDMENT]
class MSFT_MTLogicalProcessor : CIM_ManagedElement
{
  string  InstanceID;
  string  Caption;
  string  Description;
  string  ElementName;
  uint16  NodeId;
  uint16  CpuId;
  boolean Parking;
  uint16  IntervalSeconds;
  uint16  CurrentIndex;
  real32  Utilization[];
  real32  Privileged[];
};

Members

The MSFT_MTLogicalProcessor class has these types of members:

Properties

The MSFT_MTLogicalProcessor class has these properties.

Caption

Data type: string

Access type: Read-only

Qualifiers: MaxLen (64)

The Caption property is a short textual description (one- line string) of the object.

This property is inherited from CIM_ManagedElement.

CpuId

Data type: uint16

Access type: Read-only

Qualifiers: key

Gets the identification number of logical processor.

CurrentIndex

Data type: uint16

Access type: Read-only

Gets the current data sample index. The increment at every data sample.

Description

Data type: string

Access type: Read-only

The Description property provides a textual description of the object.

This property is inherited from CIM_ManagedElement.

ElementName

Data type: string

Access type: Read-only

Gets a user-friendly name for the object. This property allows each instance to define a user-friendly name in addition to its key properties, identity data, and description information. Note that the Name property of CIM_ManagedSystemElement is also defined as a user-friendly name. But, it is often subclassed to be a Key. It is not reasonable that the same property can convey both identity and a user-friendly name, without inconsistencies. Where Name exists and is not a Key (such as for instances of CIM_LogicalDevice), the same information can be present in both the Name and ElementName properties. Note that if there is an associated instance of CIM_EnabledLogicalElementCapabilities, restrictions on this properties may exist as defined in ElementNameMask and MaxElementNameLen properties defined in that class.

This property is inherited from CIM_ManagedElement.

InstanceID

Data type: string

Access type: Read-only

InstanceID is an optional property that may be used to opaquely and uniquely identify an instance of this class within the scope of the instantiating Namespace. Various subclasses of this class may override this property to make it required, or a key. Such subclasses may also modify the preferred algorithms for ensuring uniqueness that are defined below. To ensure uniqueness within the NameSpace, the value of InstanceID should be constructed using the following "preferred" algorithm: "OrgID:LocalID" Where OrgID and LocalID are separated by a colon (:), and where OrgID must include a copyrighted, trademarked, or otherwise unique name that is owned by the business entity that is creating or defining the InstanceID or that is a registered ID assigned to the business entity by a recognized global authority. (This requirement is similar to the <Schema Name>_<Class Name> structure of Schema class names.) In addition, to ensure uniqueness, OrgID must not contain a colon (:). When using this algorithm, the first colon to appear in InstanceID must appear between OrgID and LocalID. LocalID is chosen by the business entity and should not be reused to identify different underlying (real-world) elements. If not null and the above "preferred" algorithm is not used, the defining entity must assure that the resulting InstanceID is not reused across any InstanceIDs produced by this or other providers for the NameSpace of this instance. If not set to null for DMTF-defined instances, the "preferred" algorithm must be used with the OrgID set to "CIM".

This property is inherited from CIM_ManagedElement.

IntervalSeconds

Data type: uint16

Access type: Read-only

Gets the current data collection interval in seconds.

NodeId

Data type: uint16

Access type: Read-only

Qualifiers: key

Gets the identification number of the NUMA node or processor socket. If empty, it presents an aggregated NUMA, or the Socket itself.

Parking

Data type: boolean

Access type: Read-only

Gets a value that is true if the processor is in a parked state; otherwise, false.

Privileged

Data type: real32 array

Access type: Read-only

Gets a list of historical statistics of percentage of privileged kernel utilization on the logical processor. The statistics are logged with the latest 60 samples, with each interval defined in IntervalSeconds (second).

Utilization

Data type: real32 array

Access type: Read-only

Gets a list of historical statistics of percentage of utilization on the logical processor. The statistics are logged with the latest 60 samples, with each interval defined in IntervalSeconds (second).

Requirements

Minimum supported client
None supported
Minimum supported server
Windows Server 2016
Namespace
Root\Microsoft\Windows\ManagementTools
MOF
MtTmProv.mof
DLL
MtTmProv.dll

See also

CIM_ManagedElement

Management Tools Task Manager WMI Provider