Element ID / Rule name: Project_Active_Directory_Connection_Failed
Summary: This monitor indicates that Microsoft Project Web App could not access the Active Directory directory service.When an administrator browses to the "Active Directory Enterprise Resource Pool Synchronization" or "Add or Edit Group" page by using Project Web App, Project Web App checks the current availability of the Active Directory forests. This check determines whether the Find Group button on those pages is enabled. If the Find Group button is available, administrators can use it to choose which Active Directory group to use for synchronization.
Cause: One or more of the following situations might be the cause:
The Microsoft Project Server application server is using a SharePoint Service Account (SA) account that does not have read access to Active Directory.
The Project Server application server may no longer be joined to an Active Directory domain.
The Project Server application server does not currently have network access to the domain.
Ports required for Project Server and Active Directory to communicate are not open between the Project Server application server and the Active Directory store. This can occur if a firewall is configured to block a port described in the following list:
389/UDP – LDAP: LDAP is the Lightweight Directory Access Protocol that is designed to provide a standard way to access directory services. LDAP is the primary protocol used to access an Active Directory store.
636/TCP – LDAP over SSL: When Secure Sockets Layer (SSL) is enabled, the LDAP data that is transmitted and received is encrypted.
3268/TCP – Microsoft Global Catalog: Active Directory global catalogs listen on this port.
3269/TCP – Microsoft Global Catalog with LDAP/SSL: Microsoft global catalog SSL connections listen on this port.
Possible resolutions include:
Verify that the service account used by the SA used by the Project Server application server is a domain account that has read access to Active Directory.
Verify that the Project Server application server is joined to an Active Directory domain.
Verify that the Project Server application server has network access.
Verify that the ports listed in the previous section are open between the Active Directory store and the Project Server application server.
See Also
Other Resources
Project Active Directory connection failed
Project Active Directory exception occurred during synchronization
Project Active Directory nested foreign security principal could not be resolved
Project Active Directory nested object could not be resolved
Project Active Directory PWA group could not be resolved
Project Active Directory top-level group has no members
Falha do projeto ao criar Web da central de relatórios
Project Cube Build Service Analysis Services server connection failure
Project Cube Build Service Analysis Services server lock time out
Project Cube Build Service attempt to overwrite failed
Project Cube Build Service Decision Support Object is not installed
Project notification XSLT transformation error
Falha ao criar espaço de trabalho do Project
Project General Data Access Layer error connecting to database
Project General Data Access Layer error while getting connection strings
Project notification e-mail delivery failed
Project notification XSLT transformation error
Porcentagem geral de repetições de SQL por dia da fila de projetos
Project Queue general percentage SQL retries per hour
Project Queue jobs average wait time per day
Project queue jobs percentage jobs failed per day
Project queue jobs percentage failed per hour
Project Queue System restarting due to unexpected error
Project Reporting server side event has failed
Project Server event handler could not be found
Project Server event service could not be found
Project SQL user view refresh message was not queued
Project user view was truncated
Erro no formato dos Serviços do Project Windows SharePoint
Tempo médio do Project Winproj para abertura do projeto
Project Winproj average percentage of incremental save to full save
Project workspace user synchronization failed