EWF Configuration in Target Designer

Using the EWF Configuration Settings window of the Target Designer to configure EWF as a Windows XP Embedded component during the offline design phase For example:

Aa940807.ewf_configui_screenshot2(en-US,WinEmbedded.5).gif

The following table explains the items shown in the EWF Configuration Settings window:

Number of Protected Volumes Sets the number of volumes EWF will protect. Range: 1-9
Maximum Number of Overlay Levels Sets the maximum overlay level for DISK overlays. Range: 1-9. (Always 1 for RAM overlays.)
EWF Partition Size in KBytes Sets the size of the EWF partition. Defaults to 1024 for DISK overlays, value is N/A for RAM overlays.
Disable Background Disk Defragmentation Yes/no checkbox
Enable HORM Yes/no checkbox
Protected Volume Prev/Next Buttons Moves to individual settings for each protected volume (governed by # volumes option above)
Start EWF Enabled Yes/no checkbox (per volume)
Enable Lazy Write Yes/no checkbox (per volume – enables "Lazy write" mode)
Disk Number Specifies disk(x) value in arc path for this volume
Partition Number Specifies partition(x) value in arc path for this volume
Overlay Type Select between DISK, RAM and RAM(Reg) modes for this volume
Optimization Option Select options to optimize EWF performance