Bewerken

Delen via


WIA_PROPERTY_INFO structure (wiamindr_lh.h)

The WIA_PROPERTY_INFO structure is used to store default access and valid value information for an item property of arbitrary type.

Syntax

typedef struct _WIA_PROPERTY_INFO {
  ULONG   lAccessFlags;
  VARTYPE vt;
  union {
    struct {
      LONG Min;
      LONG Nom;
      LONG Max;
      LONG Inc;
    } Range;
    struct {
      DOUBLE Min;
      DOUBLE Nom;
      DOUBLE Max;
      DOUBLE Inc;
    } RangeFloat;
    struct {
      LONG cNumList;
      LONG Nom;
      BYTE *pList;
    } List;
    struct {
      LONG   cNumList;
      DOUBLE Nom;
      BYTE   *pList;
    } ListFloat;
    struct {
      LONG cNumList;
      GUID Nom;
      GUID *pList;
    } ListGuid;
    struct {
      LONG cNumList;
      BSTR Nom;
      BSTR *pList;
    } ListBStr;
    struct {
      LONG Nom;
      LONG ValidBits;
    } Flag;
    struct {
      LONG Dummy;
    } None;
  } ValidVal;
} WIA_PROPERTY_INFO, *PWIA_PROPERTY_INFO;

Members

lAccessFlags

Specifies the access and property attribute flags for a property. For more information, see Property Attributes.

vt

Specifies the variant data type for the property. This member, which can be one of the following, controls which structure member of the ValidValunion is valid:

  • VT_UI1

  • VT_UI2

  • VT_UI4

  • VT_I2

  • VT_I4

  • VT_R4

  • VT_R8

  • VT_CLSID

  • VT_BSTR

For more information, see PROPVARIANT.

ValidVal

ValidVal.Range

A structure that is filled when the property's valid values are specified by a range of integer values.

ValidVal.Range.Min

The minimum value of the property.

ValidVal.Range.Nom

The property's nominal value.

ValidVal.Range.Max

The maximum value of the property.

ValidVal.Range.Inc

The increment value that can be used.

ValidVal.RangeFloat

A structure that is filled when the property's valid values are specified by a range of floating-point values and the property type is a float or double.

ValidVal.RangeFloat.Min

The minimum value of the property.

ValidVal.RangeFloat.Nom

The property's nominal value.

ValidVal.RangeFloat.Max

The maximum value of the property.

ValidVal.RangeFloat.Inc

The increment value that can be used.

ValidVal.List

A structure that is filled when the property's valid values are specified by a list of integer values.

ValidVal.List.cNumList

The number of elements in the array of valid values to which pList points.

ValidVal.List.Nom

The nominal value of the property.

ValidVal.List.pList

An array of valid values the property can be set to.

ValidVal.ListFloat

A structure that is filled when the property's valid values are specified by a list of floating-point values.

ValidVal.ListFloat.cNumList

The number of elements in the array of valid values to which pList points.

ValidVal.ListFloat.Nom

The nominal value of the property.

ValidVal.ListFloat.pList

An array of valid values the property can be set to.

ValidVal.ListGuid

A structure that is filled when the property's valid values are specified by a list of GUIDs.

ValidVal.ListGuid.cNumList

The number of elements in the array of valid values to which pList points.

ValidVal.ListGuid.Nom

The nominal value of the property.

ValidVal.ListGuid.pList

An array of valid values the property can be set to.

ValidVal.ListBStr

A structure that is filled when the property's valid values are specified by a list of strings.

ValidVal.ListBStr.cNumList

The number of elements in the array of valid values to which pList points.

ValidVal.ListBStr.Nom

The nominal value of the property.

ValidVal.ListBStr.pList

An array of valid values the property can be set to.

ValidVal.Flag

A structure that is filled when the property's valid values are specified by a bitset of flags.

ValidVal.Flag.Nom

The nominal value of the property.

ValidVal.Flag.ValidBits

A mask indicating which bit values can be set. This member should be a bitwise OR of all possible user-defined flag values.

ValidVal.None

A structure that is filled when the property's valid values are not given in a list, range, or bitset. This structure contains a member named Dummy, which indicates the property is of type NONE.

ValidVal.None.Dummy

Remarks

The WIA_PROPERTY_INFO is used by the minidriver to store information about a property of arbitrary type. This structure is also used by the wiasSetItemPropAttribs to set a property's valid values. The lAccessFlags member controls whether access to a property is read-only or read/write. This member also conveys information about the set of valid values for a property when they are defined by a list of values, a range of values, or a bitset of flags. The vt member contains information about the type of the property. Both members should be used to determine which member of the ValidValunion can be accessed.

For example, for a read/write property of type long, whose valid values are integers in the range -128 to 127, and whose nominal value is 0, lAccessFlags would be set to WIA_PROP_RW | WIA_PROP_RANGE, and vt would be set to VT_I4. Range.Min would be set to -128, Range.Max would be set to 127, and Range.Inc would be set to 1. Range.Nom would be set to 0.

For a different property whose valid values are defined by a list of three GUID values, lAccessFlags would have its WIA_PROP_LIST bit set, and vt would be set to VT_CLSID. ListGuid.cNumList would be set to 3, and the three GUIDs are ListGuid.pList[0], ListGuid.pList[1], and ListGuid.pList[2].

A property whose valid values are defined by a bitset of the values 0x01, 0x02, 0x04, and 0x08 would have the WIA_PROP_FLAG bit set in lAccessFlags, and vt would be set to VT_UI4. For such a property, the value stored in Flag.ValidBits would be 0x0F, the bitwise OR of the four flag values previously mentioned.

The following examples show how to use array data with WIA_PROPERTY_INFO and how to call wiasWriteMultiple to set your property values.

Initialization might look like the following example:

// Initialize WIA_IPA_ITEM_TIME (NONE)
  g_pszItemDefaults[13]              = WIA_IPA_ITEM_TIME_STR;
  g_piItemDefaults [13]              = WIA_IPA_ITEM_TIME;
  g_pvItemDefaults [13].cai.celems   = MyNumberOfElements;
  g_pvItemDefaults [13].cai.pelems   = PointerToMyArray;
  g_pvItemDefaults [13].vt           = VT_VECTOR|VT_UI2; // MyArray is an array of DWORD values
  g_psItemDefaults [13].ulKind       = PRSPEC_PROPID;
  g_psItemDefaults [13].propid       = g_piItemDefaults [13];
  g_wpiItemDefaults[13].lAccessFlags = WIA_PROP_READ|WIA_PROP_NONE;
  g_wpiItemDefaults[13].vt           = g_pvItemDefaults [13].vt;

At run time, changing the value with wiasWriteMultiple might look like the following example:

PROPVARIANT propVar;
PROPSPEC    propSpec;
PropVariantInit(&propVar);
propVar.vt          = VT_VECTOR | VT_UI2;
propVar.caui.cElems = sizeof(SYSTEMTIME) / sizeof(WORD);
propVar.caui.pElems = (WORD *) &CurrentTimeStruct;
propSpec.ulKind     = PRSPEC_PROPID;
propSpec.propid     = WIA_IPA_ITEM_TIME;
hr                  = wiasWriteMultiple(pWiasContext, 1, &propSpec, &propVar);

WIA uses the COM PROPVARIANT type, VARIANT, so the default is VT_VECTOR, and not VT_ARRAY (which is also supported).

Requirements

Requirement Value
Header wiamindr_lh.h (include Wiamindr.h)

See also

wiasSetItemPropAttribs