iSCSI Target iSNS Test (LOGO)

This test verifies that target devices (for example, disk, tape, and media changer devices) can properly register with and be discovered by an Internet Storage Name Service (iSNS) server.

This test verifies that the Microsoft iSCSI initiator can log on to the device that you are testing by using the information that the target registers with the iSNS server. The test first clears all existing discovery information on the initiator and adds the iSNS server as the only discovery mechanism. The test then verifies that the device under test is found by using the iSNS server. The test then verifies it can log on to the target.

Test details

Associated requirements

Device.Storage.Hd.Iscsi.BasicFunction

See the device hardware requirements.

Platforms

Windows 7 (x64) Windows 7 (x86) Windows 8 (x64) Windows 8 (x86) Windows Server 2012 (x64) Windows Server 2008 R2 (x64) Windows Server 2008 x64 Windows Server 2008 x86Windows 8.1 x64Windows 8.1 x86Windows Server 2012 R2

Expected run time

~10 minutes

Categories

Certification Functional

Type

Manual

 

Running the test

Before you run the test, complete the test setup as described in the test requirements: iSCSI Boot Component Testing Prerequisites.

If this is the first time you are running an iSCSI HBA test, iSCSI Target test, or MPIO test over iSCSI bus type on the HCK client, or if there is no iscsihctconfig.ini under [HCK Path]\JobsWorkingDir\ on the HCK client, you will receive a pop-up dialog box to input iSCSI configuration information and/or HBA information. For more information about this dialog box, see “Running the test” in iSCSI HBA Boot Test (LOGO).

Troubleshooting

For troubleshooting information, see Troubleshooting Device.Storage Testing.

This test returns Pass or Fail. To review test details, review the test log from the Windows HCK Manager.

More information

To run this test:

  1. Before you run this test, you must register the device under test with the iSNS server.

  2. Run the test from the Windows HCK Studio.

  3. Enter the required data in the configuration dialog box that appears when this job is scheduled. For more information, go to iSCSI HBA Boot Test (LOGO).

Parameters

Parameter Description

LogVerbosity

The verbosity of logging. There are three levels of output: 0, 1, and 2. 2 is the most verbose.

Default value: 1

 

Command syntax

Command option Description

Iscsi_targetisns.exe -hct -v [LogVerbosity]

Runs the test. The –v option controls the verbosity of the logging. There are three levels of output: 0, 1, and 2. 2 is the most verbose.

 

Note  

For command-line help for this test binary, type /h.

 

File list

File Location

Iscsi_targetisns.exe

<[testbinroot]>\nttest\driverstest\storage\wdk\iscsi\

 

 

 