Delen via


Processor Amplification Control Test (WoW64)

This automated test verifies the presence and correctness of ProcAmpControl support of the video driver.

The test (based on DX7) attempts to create and use the ProcAmpControl device, a construct that is exposed through the DXVA1.0 Device Driver Interface (DDI). For each of the supported ProcAmp capabilities, and sometimes for combined capabilities, the test performs the following actions:

  • Verifies that the range, minimum, maximum, default values, and step size comply with the specification

  • Sets random, minimum, maximum, or invalid values; performs the Blt operations; and compares the output values with the expected values

If failures occur, the test logs the corresponding parameters, in addition to the actual and expected output values (or, in the case of noncompliance, the exact cause of failure).

Test details

Associated requirements

Device.Graphics.AdapterRender.MinimumDirectXLevel

See the device hardware requirements.

Platforms

Windows 7 (x64) Windows 8 (x64) Windows Server 2012 (x64) Windows Server 2008 R2 (x64) Windows 8.1 x64 Windows Server 2012 R2

Expected run time

~5 minutes

Categories

Certification

Type

Automated

 

Running the test

Before you run the test, complete the test setup as described in the test requirements: Graphic Adapter or Chipset Testing Prerequisites.

Troubleshooting

For troubleshooting information, see Troubleshooting Device.Graphics Testing.

More information

Command syntax

Command option Description

Pactest.exe -d 1 -whql

Runs the test job. The –d option sets the device index "x" (zero-based) and the –whql option is the default command-line parameter for Windows HCK testing.

 

Note  

For command-line help for this test binary, type /h.

 

File List

File Location

Configdisplay.exe

<[testbinroot]>\nttest\windowstest\tools\

Pactest.exe

<[testbinroot]>\nttest\

TDRWatch.exe

<[testbinroot]>\nttest\windowstest\graphics\

 

 

 

Send comments about this topic to Microsoft