다음을 통해 공유


CBaseReferenceClock::AdviseTime (Windows CE 5.0)

Send Feedback

Sets up a one-shot notification with the clock.

HRESULT AdviseTime(REFERENCE_TIMEbaseTime,REFERENCE_TIMEstreamTime,HEVENThEvent,DWORD* pdwAdviseToken);

Parameters

  • baseTime
    Base reference time.
  • streamTime
    Stream offset time.
  • hEvent
    Advise through this event.
  • pdwAdviseToken
    Where the advise token goes.

Return Values

Returns one of the following HRESULT values.

E_OUTOFMEMORY Out of memory.
E_INVALIDARG Invalid argument.
NOERROR No error.

Remarks

This member function implements the IReferenceClock::AdviseTime method.

At the time specified in the baseTime plus the streamTime parameters, the event specified in hEvent is set.

It is correct to call CBaseReferenceClock::Unadvise to remove the link after the event occurs, but it is not necessary. One-shot notifications are cleared by the clock when they have signaled.

To cancel a one-shot notification before the time is reached, call Unadvise and pass the pdwAdviseToken value returned from this call.