MSPY3 supports the following Input Method Management (IMM) functions for EUDP management:

ImmRegisterWord and ImmUnregisterWord both return a Boolean value to indicate either success or failure. Because these functions do not provide a specific cause for the failure, MSPY3 sets the most recent error code to indicate the cause. The error codes are the same for both functions. To obtain the error cause when the call to ImmRegistryWord fails, your application must call the GetLastError function. The following table shows the error codes MSPY3 can return. All error codes are DWORDs.

Error code Description
0x20000001 Phrases longer than nine characters are not supported.
0x20000002 The EUDP term contains surrogate, ANSI, symbol, or extended characters.
0x20000005 A duplicate term exists in the built-in dictionary.
0x20000006 A duplicate term exists in the EUDP file.
0x20000009 Single characters are not supported.
0x2000000A The EUDP has an invalid reading.
0x2000000B The EUDP file is full.
0x2000000C Fatal error, including out of memory.

MSPY3 exposes the ClearEudpContent function, which allows an application to delete the entire contents of a EUDP file.