다음을 통해 공유


CM_PPPEntries Configuration Service Provider (Windows Embedded CE 6.0)

1/6/2010

You can use the CM_PPPEntries configuration service provider to configure the point-to-point protocol (PPP) entries on the device. The configuration service provider defines the settings for Remote Access Service (RAS) connections. General packet radio service (GPRS) connections are configured using the CM_GPRSEntries configuration service provider.

Note

This configuration service provider is managed over the Open Mobile Alliance (OMA) client provisioning (formerly WAP client provisioning) protocol. For information about OMA client provisioning, see Configuring Device Connection Settings by using OMA XML. Access to this configuration service provider is determined by security roles. Because OEMs and mobile operators can selectively disallow access, ask them about the availability of this configuration service provider.

In the root characteristic, the default security roles are defined. The following table shows the default settings.

Permissions

Read/Write

Roles allowed to query and update setting

Manager

AuthenticatedUser

The following image shows the configuration service provider in tree format as used by OMA client provisioning.

Ee497135.1542979a-ab85-4b71-a647-e5b836d30f10(en-US,WinEmbedded.60).gif

Characteristics

  • <entryname>
    Specifies the name of the connection. Fields under this characteristic specify parameters for this connection.

    Note

    The operating system does not allow duplicate entry names among the CM_VPNEntries, CM_PPPEntries, and CM_GPRSEntries connection service providers.

  • <entryname>/DevSpecificCellular
    Sets parameters in the device-specific structure, which is passed by RAS to the cellular TAPI device through lineSetDevConfig before initiating the connection. This characteristic is valid only for connections that use the cellular telephony application programming interface (TAPI) service provider.
  • <entryname>/DevSpecificUnimodem
    Sets parameters in the device-specific structure, which is passed by RAS to the unimodem TAPI device through lineSetDevConfig before initiating the connection. This characteristic is valid only for connections that use the unimodem TAPI service provider.

Parameters

  • AltDnsAddr
    This parameter is used in the <entryname> characteristic and is placed in the ipaddrDnsAlt member of the RASENTRY structure. For more information about RASENTRY, see MSDN.

Note

Once configured, the AltDnsAddr parameter cannot be set to null by configuration with a blank string. The only way to change the setting is to pass in the value "0.0.0.0".

The following table shows the default settings.

Permissions

Read/Write

Data type

String

Roles allowed to query and update setting

Manager

Operator TPS

AuthenticatedUser

  • AltWinsAddr
    This parameter is used in the <entryname> characteristic and is placed in the ipaddrWinsAlt member of the RASENTRY structure. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • AlwaysOn
    Used in the <entryname> characteristic to specify whether the connection supports AlwaysOn. Permitted values are false (AlwaysOn not supported) and true (AlwaysOn supported).

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • AreaCode
    This parameter is used in the <entryname> characteristic and is placed in the szAreaCode member of the RASENTRY structure. AreaCode specifies the area code portion of the phone number. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Label

    Area code:

    Semantic type

    phone-number

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • BearerInfoConnectionElement
    This parameter is used in the <entryname>/DevSpecificCellular characteristic and is placed in the dwConnectionElement member of the CELLDEVCONFIG structure.

    See GSM specification 07.07 "6.7 Select bearer service type +CBST" for more information. The following table lists the possible values.

    Value Description

    1

    Transparent

    2

    NonTransparent

    3

    BothTransparent

    4

    Both NonTransparent

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • BearerInfoService
    This parameter is used in the <entryname>/DevSpecificCellular characteristic and is placed in the dwService member of the CELLDEVCONFIG structure. Permitted values are one of the CELLDEVCONFIG_SERVICE_* values defined in tsp.h. See GSM specification 07.07 "6.7 Select bearer service type +CBST" for more information. The following table lists the possible values.

    Value Description

    1

    Async Modem

    2

    Sync Modem

    3

    Async PAD Access

    4

    Sync Packet Access

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • BearerInfoSpeed
    This parameter is used in the <entryname>/DevSpecificCellular characteristic and is placed in the dwSpeed member of the CELLDEVCONFIG structure. Permitted values are one of the CELLDEVCONFIG_SPEED_* values defined in tsp.h. See GSM specification 07.07 "6.7 Select bearer service type +CBST" for more information. The following table lists the possible values.

    Value Description

    1

    Auto

    2

    300 v21

    3

    300 v110

    4

    12000 v22

    5

    1200/75 v23

    6

    1200 v110

    7

    1200 v120

    8

    2400 v22bis

    9

    2400 v26ter

    10

    2400 v110

    11

    2400 v120

    12

    4800 v32

    13

    4800 v110

    14

    4800 v120

    15

    9600 v32

    16

    9600 v34

    17

    9600 v110

    18

    9600 v120

    19

    14400 v34

    20

    14400 v110

    21

    14400 v120

    22

    19200 v34

    23

    19200 v110

    24

    19200 v120

    25

    28800 v34

    26

    28800 v110

    27

    28800 v120

    28

    38400 v110

    29

    38400 v120

    30

    48000 v110

    31

    48000 v120

    32

    56000 v110

    33

    56000 v120

    34

    56000 Transparent

    35

    64000 Transparent

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • BearerInfoValid
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify whether other bearer information parameters are valid. Permitted values are 0 (zero) for OFF or 1 for ON. The value is placed in the bBearerInfoValid member of the CELLDEVCONFIG structure associated with the connection (defined in the tsp.h header file).

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • CompressionInfoDirection
    This parameter is used in the <entryname>/DevSpecificCellular characteristic and is placed in the dwDirection member of the CELLDEVCONFIG structure.

    See "ITU-T Recommendation V.25 ter"**Section 6.6.1 for more information. The following table lists the possible values.

    Value Description

    1

    None

    2

    Transmit

    3

    Receive

    4

    Both

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • CompressionInfoMaxDictEntries
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to control the maximum number of dictionary entries for V.42bis data compression. The value is placed in the dwMaxDictEntries member of the CELLDEVCONFIG structure. See "ITU-T Recommendation V.25 ter"**Section 6.6.1 for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • CompressionInfoMaxStringLength
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to control the maximum string length for V.42bis data compression. The value is placed in the dwMaxStringLength member of the CELLDEVCONFIG structure. See "ITU-T Recommendation V.25 ter"**Section 6.6.1 for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • CompressionInfoRequired
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify whether data compression is required. Permitted values are 0 (zero) for OFF or 1 for ON. This value is placed in the dwRequired member of the CELLDEVCONFIG structure. See "ITU-T Recommendation V.25 ter"**Section 6.6.1 for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • CompressionInfoValid
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify whether other radio link information parameters are valid. Permitted values are 0 (zero) for OFF or 1 for ON. The value is placed in the bDataCompInfoValid member of the

    CELLDEVCONFIG, CELLDATACOMPINFO, CELLGPRSCONNECTIONINFO, and CELLRADIOLINKINFO structures. For more information see, CELLDEVCONFIG, CELLDATACOMPINFO, CELLGPRSCONNECTIONINFO, and CELLRADIOLINKINFO.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • CountryCode
    This numeric parameter is used in the <entryname> characteristic and is placed in the dwCountryCode member of the RASENTRY structure. CountryCode specifies the country/region code portion of the phone number. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Label

    Country/region code:

    Semantic type

    phone-number

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Desc.<langid>
    This parameter is used in the <entryname> characteristic. A tag in the format of Desc.<langid> will be used as the language specific identifier for that entry. For example, the field <parm name="Desc.0409" value="PPP Dialup" /> will force PPP Dialup to appear in the UI to represent this connection when the device is set to English language (language ID 0409). Descriptions for multiple languages may be provisioned using this mechanism, and the system will automatically switch among them if the user changes language preferences on the device. If no Desc tag is provisioned for a given language, the system will default to the characteristic tag name used to create the entry.

    The following table shows the default settings.

    Permissions

    Read/Write

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • DestId
    This parameter is used in the <entryname> characteristic as a GUID that represents the unique ID of the network to which this entry connects. See the connmgr.h header for predefined GUID values IID_DestNet*.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Label

    Connects to

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • DeviceName
    This parameter is used in the <entryname> characteristic and is placed in the szDeviceName member of the RASENTRY structure. DeviceName specifies the local portion of the phone number. For more information about RASENTRY, see MSDN.

    This string contains the name of a TAPI device to use with this phone-book entry, for example "XYZ Corp 28800 External." To enumerate the number of available RAS-capable devices, use the lineInitialize function.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • DeviceSpecificRAW
    This parameter is used in the <entryname> characteristic to allow querying or setting the TAPI device-specific data structure associated with the RAS entry. This duplicates the functionality of the various XML tags under the DevSpecificCellular and DevSpecificUnimodem characteristics, and also allows the setting of the device-specific information for other non-standard TAPI service providers. It should be used with great caution because it allows direct manipulation of the underlying data structures used by the TAPI service provider. The string value is interpreted as a hexadecimal byte stream, for example the string "FFFFFFFF" will set the structure to a single DWORD with all bits set. The resulting structure is passed into the TAPI service provider through lineSetDevConfig each time the connection is brought up.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • DeviceType
    This parameter is used in the <entryname> characteristic and is placed in the szDeviceType member of the RASENTRY structure. The default value for the szDeviceType is "modem". For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • DialAsLocalCall
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_DialAsLocalCall member in the RASENTRY structure. Permitted values are 0 for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    Note

    For cellular devices, this member is typically ignored, and the system is programmed to dial the full canonical number, for example +<country/region code><area code><local number>.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • DnsAddr
    This parameter is used in the <entryname> characteristic and is placed in the ipaddrDns member of the RASENTRY structure. For more information about RASENTRY, see MSDN.

Note

Once configured, the DnsAddr parameter cannot be set to null by configuration with a blank string. The only way to change the setting is to pass in the value "0.0.0.0".

The following table shows the default settings.

Permissions

Read/Write

Data type

String

Roles allowed to query and update setting

Manager

Operator TPS

AuthenticatedUser

  • Domain
    This parameter is used in the <entryname> characteristic and is placed in the szDomain member of the RASDIALPARAMS structure. This parameter specifies the domain to be used during authentication. For more information about RASDIALPARAMS, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Label

    Domain:

    Semantic type

    URL

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Enabled
    This parameter can be used in the <entryname> characteristic to enable or disable a connection entry without removing it from the system. The following table lists the possible values.

    Value Description

    0

    The connection entry is disabled

    1

    The connection entry is enabled

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • FrameSize
    This parameter is used in the <entryname> characteristic and is placed in the dwFrameSize member of the RASENTRY structure. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Framing
    This parameter is used in the <entryname> characteristic and is placed in the dwFramingProtocol member of the RASENTRY structure. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • IpAddr
    This parameter is used in the <entryname> characteristic and is placed in the ipaddr member of the RASENTRY structure. IpAddr specifies the IP address to be used while this connection is active. This member is ignored unless dwfOptions specifies the RASEO_SpecificIpAddr member. For more information about RASENTRY, see MSDN.

    The following table shows the default settings for this parameter.

    Permissions

    Read/Write

    Data type

    String

    Label

    IP address:

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • IpHeaderCompression
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_IpHeaderCompression member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Password
    This parameter is used in the <entryname> characteristic and is placed in the szPassword member of the RASDIALPARAMS structure. The Password parameter specifies the password to be used during authentication. If left empty, the system will optionally automatically prompt for the user name and password when making a connection. The RequirePw member controls this behavior. Queries of this field will return a string composed of asterisks (*).

    On operations to set the password, passing in this same string will cause the new password to be ignored and will not change the existing password.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Label

    Password:

    Semantic type

    alphanumeric-password

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Phone
    This parameter is used in the <entryname> characteristic and is placed in the szLocalPhoneNumber member of the RASENTRY structure. The Phone parameter specifies the local portion of the phone number. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Label

    Phone number:

    Semantic type

    phone-number

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoAckTimer
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify the value to be placed in the dwAckTimer member of the CELLRADIOLINKINFO structure.

    See GSM specification 07.07 "6.8 Radio link protocol +CRLP" T1 parameter for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoIws
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify the value to be placed in the dwIws member of the CELLRADIOLINKINFO. See GSM specification 07.07 "6.8 Radio link protocol +CRLP" iws parameter for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoMws
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify the value to be placed in the dwMws member of the CELLRADIOLINKINFO structure. See GSM specification 07.07 "6.8 Radio link protocol +CRLP" mws parameter for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoResequenceTimer
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify the value to be placed in the dwResequenceTimer member of the CELLBEARERINFO, CELLDATACOMPINFO, CELLGPRSCONNECTIONINFO, and CELLRADIOLINKINFO structures. See GSM specification 07.07 "6.8 Radio link protocol +CRLP" T4 parameter for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoRetransmitAttempts
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify the value to be placed in the dwRetransmitAttempts member of the CELLRADIOLINKINFO structure. See GSM specification 07.07 "6.8 Radio link protocol +CRLP" N2 parameter for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoValid
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify whether other radio link information parameters are valid. Permitted values are 0 (zero) for OFF or 1 for ON. The value is placed in the bRadioLinkInfoValid member of the CELLDEVCONFIG structure.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RadioLinkInfoVersion
    This parameter is used in the <entryname>/DevSpecificCellular characteristic to specify the value to be placed in the dwVersion member of the CELLRADIOLINKINFO structure. See GSM specification 07.07 "6.8 Radio link protocol +CRLP" ver parameter for more information.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RemoteDefaultGateway
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_RemoteDefaultGateway member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RequireDataEncryption
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_RequireDataEncryption member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RequireEncryptedPw
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_RequireEncryptedPw member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RequireMsEncryptedPw
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_RequireMsEncryptedPw member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • RequirePw
    This parameter is used in the <entryname> characteristic to control whether the system should prompt for a user name/password/domain name before dialing the phone. If set to a 1, the system will prompt if no password or user name is provisioned. If set to 0 (zero), the system will not prompt for a password before dialing even if no password or user name is provisioned. For PPP connections, the default value of this parameter is 1.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Integer

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Script
    This parameter is used in the <entryname> characteristic and is placed in the szScript member of the RASENTRY structure. The Script parameter specifies a string containing the name of the script file. The file name should be a full path. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • Secure
    Specifies in the <entryname> characteristic if a connection is more secure. Permitted values are false (not secure) and true (more secure).

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • SpecificIpAddr
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_SpecificIpAddr member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • SpecificNameServers
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_SpecificNameServers member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • SwCompression
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_SwCompression member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • UseCountryAndAreaCodes
    This parameter is used in the <entryname> characteristic to control the setting of the RASEO_UseCountryAndAreaCodes member in the RASENTRY structure. Permitted values are 0 (zero) for OFF or 1 for ON. For more information about RASENTRY and the use of this parameter, see MSDN.

    Note

    For cellular devices, this parameter is typically ignored, and the system is programmed to dial the full canonical number, for example +<country/region code><area code><local number>.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    Boolean

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • UserName
    This parameter is used in the <entryname> characteristic and is placed in the szUserName member of the RASDIALPARAMS structure. The UserName parameter specifies the user name to be used during authentication. If the Username parameter is left empty, the system will optionally automatically prompt for the user name and password when making a connection. The RequirePw member controls this behavior.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Label

    User name:

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

  • WinsAddr
    This parameter is used in the <entryname> characteristic and is placed in the ipaddrWins member of the RASENTRY structure. WinsAddr specifies the IP address of the WINS server to be used while this connection is active. This member is ignored unless dwfOptions specifies the RASEO_SpecificNameServers member. For more information about RASENTRY, see MSDN.

    The following table shows the default settings.

    Permissions

    Read/Write

    Data type

    String

    Roles allowed to query and update setting

    Manager

    Operator TPS

    AuthenticatedUser

Microsoft Custom Elements

The following table shows the Microsoft custom elements that this configuration service provider supports for OMA client provisioning.

Element Name Description

noparm

Not supported

nocharacteristic

Supported

characteristic-query

Supported

parm-query

Supported

Use these elements to build standard OMA client provisioning (formerly WAP client provisioning) configuration XML. For more information about these elements, see https://go.microsoft.com/fwlink/?LinkId=160786.

For information about OMA client provisioning, see Configuring Device Connection Settings by using OMA XML.

See Also

Concepts

Configuration Service Providers Overview

Other Resources

Configuration Service Providers