다음을 통해 공유


OEMIntrOccurs (Windows Embedded CE 6.0)

1/5/2010

This function is called when an interrupt occurs.

This function is optional.

Syntax

DWORD OEMIntrOccurs( 
  DWORD dwSysIntr 
); 

Parameters

  • dwSysIntr
    [in] SYSINTR value.

Return Value

A SYSINTR value is returned.

Remarks

OEMIntrOccurs can be used to catch all interrupts.

Unless you want to change the rerouted SYSINTR, OEMIntrOccurs should return the SYSINTR value that was passed through dwSysIntr.

Requirements

Header Developer Implemented
Library Nk.lib
Windows Embedded CE Windows CE 5.0 and later

See Also

Reference

Optional OAL Functions
pfnOEMIntrOccurs