다음을 통해 공유


IDTSBuffer100.GetBLOBData 메서드

Retrieves an array of bytes from a binary large object (BLOB) stored in a column of a IDTSBuffer100.

네임스페이스:  Microsoft.SqlServer.Dts.Pipeline.Wrapper
어셈블리:  Microsoft.SqlServer.DTSPipelineWrap(Microsoft.SqlServer.DTSPipelineWrap.dll)

구문

‘선언
Sub GetBLOBData ( _
    hRow As Integer, _
    hCol As Integer, _
    dwOffset As UInteger, _
    ByRef lpPointer As Byte, _
    dwLength As UInteger, _
    <OutAttribute> ByRef lpdwWritten As UInteger _
)
‘사용 방법
Dim instance As IDTSBuffer100 
Dim hRow As Integer 
Dim hCol As Integer 
Dim dwOffset As UInteger 
Dim lpPointer As Byte 
Dim dwLength As UInteger 
Dim lpdwWritten As UInteger

instance.GetBLOBData(hRow, hCol, dwOffset, _
    lpPointer, dwLength, lpdwWritten)
void GetBLOBData(
    int hRow,
    int hCol,
    uint dwOffset,
    ref byte lpPointer,
    uint dwLength,
    out uint lpdwWritten
)
void GetBLOBData(
    [InAttribute] int hRow, 
    [InAttribute] int hCol, 
    [InAttribute] unsigned int dwOffset, 
    [InAttribute] unsigned char% lpPointer, 
    [InAttribute] unsigned int dwLength, 
    [OutAttribute] unsigned int% lpdwWritten
)
abstract GetBLOBData : 
        hRow:int * 
        hCol:int * 
        dwOffset:uint32 * 
        lpPointer:byte byref * 
        dwLength:uint32 * 
        lpdwWritten:uint32 byref -> unit
function GetBLOBData(
    hRow : int, 
    hCol : int, 
    dwOffset : uint, 
    lpPointer : byte, 
    dwLength : uint, 
    lpdwWritten : uint
)

매개 변수

  • dwOffset
    유형: System.UInt32
    The location in the byte data stored in the column from which to begin reading bytes.
  • lpPointer
    유형: System.Byte%
    A reference parameter that points to the first byte in the array of bytes that are retrieved.
  • dwLength
    유형: System.UInt32
    The number of bytes to retrieve from the column.
  • lpdwWritten
    유형: System.UInt32%
    An out parameter that indicates the number of bytes written to the lpPointer parameter.

주의

When retrieving data from a column that contains a BLOB, such as a DT_IMAGE, specify the starting location in the BLOB with the dwOffset parameter, and the number of bytes to retrieve in the dwLength parameter. Retrieving the data from a BLOB column in sections is recommended to avoid situations that may occur if the size of the data in the BLOB is larger than the available memory on the computer.

This method is used to retrieve a section of bytes from the column specified by the hCol parameter in the IDTSBuffer100. This method is typically used to recursively when sequentially reading BLOB sections.

참고 항목

참조

IDTSBuffer100 인터페이스