다음을 통해 공유


IDTSComponentMetaData90.FireInformation Method

Raises an OnInformation event.

네임스페이스: Microsoft.SqlServer.Dts.Pipeline.Wrapper
어셈블리: Microsoft.SqlServer.DTSPipelineWrap (in microsoft.sqlserver.dtspipelinewrap.dll)

구문

‘선언
<DispIdAttribute(128)> _
Sub FireInformation ( _
    <InAttribute> InformationCode As Integer, _
    <InAttribute> SubComponent As String, _
    <InAttribute> Description As String, _
    <InAttribute> HelpFile As String, _
    <InAttribute> HelpContext As Integer, _
    <InAttribute> <OutAttribute> ByRef pbFireAgain As Boolean _
)
[DispIdAttribute(128)] 
void FireInformation (
    [InAttribute] int InformationCode,
    [InAttribute] string SubComponent,
    [InAttribute] string Description,
    [InAttribute] string HelpFile,
    [InAttribute] int HelpContext,
    [InAttribute] out bool pbFireAgain
)
[DispIdAttribute(128)] 
void FireInformation (
    [InAttribute] int InformationCode, 
    [InAttribute] String^ SubComponent, 
    [InAttribute] String^ Description, 
    [InAttribute] String^ HelpFile, 
    [InAttribute] int HelpContext, 
    [InAttribute] [OutAttribute] bool% pbFireAgain
)
/** @attribute DispIdAttribute(128) */ 
void FireInformation (
    /** @attribute InAttribute() */ int InformationCode, 
    /** @attribute InAttribute() */ String SubComponent, 
    /** @attribute InAttribute() */ String Description, 
    /** @attribute InAttribute() */ String HelpFile, 
    /** @attribute InAttribute() */ int HelpContext, 
    /** @attribute InAttribute() */ /** @attribute OutAttribute() */ /** @ref */ boolean pbFireAgain
)
JScript는 값 유형 인수를 참조로 전달하는 것을 지원하지 않습니다.

매개 변수

  • InformationCode
    The component-defined information code.
  • SubComponent
    The name of the component that raises the event.
  • Description
    The description of the information event.
  • HelpFile
    The help file that provides more information about the error event.
  • HelpContext
    The context ID for the error.
  • pbFireAgain
    Specifies whether execution of the component is cancelled.

주의

The OnInformation event should only be raised during component execution since the information is not visibly captured during component design.

The pbFireAgain parameter is set by the runtime and indicates whether any clients are listening to the event. Components store the value of this parameter locally and should evaluate its value before raising the event again. If the value of the pbFireAgain parameter is false, the event should not be raised.

스레드 보안

Any public static (Shared in Microsoft Visual Basic) members of this type are thread safe. Any instance members are not guaranteed to be thread safe.

플랫폼

개발 플랫폼

지원되는 플랫폼 목록은 SQL Server 2005 설치를 위한 하드웨어 및 소프트웨어 요구 사항을 참조하십시오.

대상 플랫폼

지원되는 플랫폼 목록은 SQL Server 2005 설치를 위한 하드웨어 및 소프트웨어 요구 사항을 참조하십시오.

참고 항목

참조

IDTSComponentMetaData90 Interface
IDTSComponentMetaData90 Members
Microsoft.SqlServer.Dts.Pipeline.Wrapper Namespace