다음을 통해 공유


MobileNetworkServiceDataFlowTemplate Class

Definition

Data flow template.

public class MobileNetworkServiceDataFlowTemplate : System.ClientModel.Primitives.IJsonModel<Azure.ResourceManager.MobileNetwork.Models.MobileNetworkServiceDataFlowTemplate>, System.ClientModel.Primitives.IPersistableModel<Azure.ResourceManager.MobileNetwork.Models.MobileNetworkServiceDataFlowTemplate>
type MobileNetworkServiceDataFlowTemplate = class
    interface IJsonModel<MobileNetworkServiceDataFlowTemplate>
    interface IPersistableModel<MobileNetworkServiceDataFlowTemplate>
Public Class MobileNetworkServiceDataFlowTemplate
Implements IJsonModel(Of MobileNetworkServiceDataFlowTemplate), IPersistableModel(Of MobileNetworkServiceDataFlowTemplate)
Inheritance
MobileNetworkServiceDataFlowTemplate
Implements

Constructors

MobileNetworkServiceDataFlowTemplate(String, MobileNetworkSdfDirectionS, IEnumerable<String>, IEnumerable<String>)

Initializes a new instance of MobileNetworkServiceDataFlowTemplate.

Properties

Direction

The direction of this flow.

Ports

The port(s) to which UEs will connect for this flow. You can specify zero or more ports or port ranges. If you specify one or more ports or port ranges then you must specify a value other than ip in the protocol field. This is an optional setting. If you do not specify it then connections will be allowed on all ports. Port ranges must be specified as <FirstPort>-<LastPort>. For example: [8080, 8082-8085].

Protocol

A list of the allowed protocol(s) for this flow. If you want this flow to be able to use any protocol within the internet protocol suite, use the value ip. If you only want to allow a selection of protocols, you must use the corresponding IANA Assigned Internet Protocol Number for each protocol, as described in https://www.iana.org/assignments/protocol-numbers/protocol-numbers.xhtml. For example, for UDP, you must use 17. If you use the value ip then you must leave the field port unspecified.

RemoteIPList

The remote IP address(es) to which UEs will connect for this flow. If you want to allow connections on any IP address, use the value any. Otherwise, you must provide each of the remote IP addresses to which the packet core instance will connect for this flow. You must provide each IP address in CIDR notation, including the netmask (for example, 192.0.2.54/24).

TemplateName

The name of the data flow template. This must be unique within the parent data flow policy rule. You must not use any of the following reserved strings - default, requested or service.

Explicit Interface Implementations

IJsonModel<MobileNetworkServiceDataFlowTemplate>.Create(Utf8JsonReader, ModelReaderWriterOptions)

Reads one JSON value (including objects or arrays) from the provided reader and converts it to a model.

IJsonModel<MobileNetworkServiceDataFlowTemplate>.Write(Utf8JsonWriter, ModelReaderWriterOptions)

Writes the model to the provided Utf8JsonWriter.

IPersistableModel<MobileNetworkServiceDataFlowTemplate>.Create(BinaryData, ModelReaderWriterOptions)

Converts the provided BinaryData into a model.

IPersistableModel<MobileNetworkServiceDataFlowTemplate>.GetFormatFromOptions(ModelReaderWriterOptions)

Gets the data interchange format (JSON, Xml, etc) that the model uses when communicating with the service.

IPersistableModel<MobileNetworkServiceDataFlowTemplate>.Write(ModelReaderWriterOptions)

Writes the model into a BinaryData.

Applies to