CTK Testing: ICOP eBox 3300
On the ICOP 3300 BSP, the following tests are known to fail with the issues described below:
Test Type |
Description |
DirectDraw tests (DDrawtk.dll) |
Test IDs 102 (Verify Surface Creation) and 360 (Get Surface Desc) fail on the eBox 3300. |
DirectDraw Functional Tests (DDFunc.dll) | Subtest IDs 518 and 618 hang after throwing 'Access Violation' exception Subtest IDs 503, 542, 556, 603, 628, 641, 642 and 644 fail |
DirectDraw Interface Tests (DDInts.dll) | Subtest ID 1815 fails after throwing 'Access Violation' exception Subtest IDs 516, 1808 and 3078 fail. |
DirectDraw Bliting Tests (DDAutoblt.dll) | The following subtest IDs fail - 1200, 1204, 1210, 1214, 1304, 1314, 2200, 2204, 2210, 2214, 2300, 2304, 2310, 2314 |
Graphics Device Interface tests (gdit.dll) |
The following test cases are expected to fail in the gdit.dll Test Suite:
|
Two-card network card miniport driver test (ndt_2c6.dll) |
For the Two-Card Network Card Miniport Driver Test (ndt_2c6.dll), subtest IDs 3 and 4 fail on the eBox-3300 Platform. The failure occurs because the subtests expect a minimum of 32 multicast addresses, when the Ethernet adapter driver supports only 3 multicast addresses. |
One-card network card miniport driver (NDIS 6) test (ndt_1c6.dll) |
After running the One-Card Test (ndt_1c6.dll), the eBox-3300 stops working with the next key stroke and does not respond to subsequent input from the mouse/keyboard connected to it. To work around this issue, restart the device. |
Winsock tests (perf_winsock2.dll) |
The following subtests fail on the eBox for the R6040 adapter:
|
USB Performance Tests (usbperf.dll) |
The following subtests fails/hang on the ebox3300.
|
USB Host tests (usbtest.dll) |
Some subtests in USB Host tests (Golden Bridge setup) are failing for Full Speed Non-Regular packet size configuration. The failures are mostly under the Simultaneous & Isochronous loopback tests. |
For additional eBox 3300 specific information, please consult directly with ICOP Technology Inc.