IOCTL_HAL_TRANSLATE_IRQ (Compact 2013)
10/16/2014
This I/O control message is not supported. Instead, use IOCTL_HAL_REQUEST_SYSINTR.
Send this message with OEMIoControl.
Syntax
BOOL OEMIoControl(
DWORD dwIoControlCode, // use IOCTL_HAL_TRANSLATE_IRQ
LPVOID lpInBuffer, // pointer to input buffer
DWORD nInBufferSize, // input buffer size
LPVOID lpOutBuffer, // pointer to output buffer
DWORD nOutBufferSize, // output buffer size
LPDWORD lpBytesReturned // number of bytes returned
);
Parameters
- dwIoControlCode
[in] Control code for the operation. Use IOCTL_HAL_TRANSLATE_IRQ for this operation.
- lpInBuffer
[in] IRQ to translate into a SYSINTR.
- nInBufferSize
[in] Set to the size of lpInBuffer.
- lpOutBuffer
[out] SYSINTR translated from an IRQ.
- nOutBufferSize
[in] Set to the size of lpOutBuffer.
- lpBytesReturned
[in] If not NULL, set to sizeof(DWORD).
Return Values
Returns TRUE if successful; otherwise, returns FALSE.
Remarks
To get extended error information, call GetLastError. GetLastError may return other standard error messages as appropriate.
Requirements
Header |