Condividi tramite


Winsock’s Listen() Backlog Offers More Flexibility In Windows 8+

Jeff here from the SDK team.

A customer was writing a high performance computing type application that needed to handle lots of incoming winsock connections all at the same time.

Normally the listen() API is used to control the maximum number of incoming (backlogged) requests, but there is a caveat with the listen() API, we don't define the maximum limit of incoming requests that are allowed.

Per MSDN:
A value for the backlog of SOMAXCONN is a special constant that instructs the underlying service provider responsible for socket s to set the length of the queue of pending connections to a maximum reasonable value.

On Windows Sockets 2, this maximum value defaults to a large value (typically several hundred or more). When calling the listen function in a Bluetooth application, it is strongly recommended that a much lower value be used for the backlog parameter (typically 2 to 4), since only a few client connections are accepted. This reduces the system resources that are allocated for use by the listening socket. This same recommendation applies to other network applications that expect only a few client connections.

Starting in Windows 8, there is a new parameter for the listen() API.

/* Maximum queue length specifiable by listen. */
#define SOMAXCONN 0x7fffffff
#define SOMAXCONN_HINT(b) (-(b))

While SOMAXCONN was defined as 0x7fffffff, it was limited to a few hundred in Winsock 2, or as few as 5 in Winsock 1.

In Windows 8, we can pass in any number we want with the macro SOMAXCONN_HINT(b). So now in Windows 8, you have much more control over how many connections listen() will accept/backlog.

Enjoy.

/Jeff

Follow us on Twitter, www.twitter.com/WindowsSDK.

Comments

  • Anonymous
    June 02, 2015
    While SOMAXCONN was defined as 0x7fffffff, it was limited to a few hundred in Winsock 2 Exactly how much ? and how much is it now (There must be a limit). I am currently developing a Java application that simulates the clients for a server. If I create too many connections too fast , then Connections are refused and thus I feel there is a hard limit on backlog queue. Can anyone please tell what's the hard limit.

  • Anonymous
    June 02, 2015
    Since it isn't published it is subject to change, but it appears it is limited to 200.