Partager via


HidP_GetUsageValue (Windows CE 5.0)

Send Feedback

This function extracts the data associated with a HID control value that matches selection criteria in a HID report.

NTSTATUS HidP_GetUsageValue(  HIDP_REPORT_TYPE ReportType,  USAGE UsagePage,  USHORT LinkCollection,  USAGE Usage,  PULONG UsageValue,  PHIDP_PREPARSED_DATA PreparsedData,  PCHAR Report,  ULONG ReportLength);

Parameters

  • ReportType
    [in] HIDP_REPORT_TYPE enumerator value that identifies the report type.
  • UsagePage
    [in] Usage page of the value.
  • LinkCollection
    [in] Link collection that contains the value. If LinkCollection is nonzero, the function only searches for the usage in this link collection; otherwise, if LinkCollection is zero, the function searches for the usage in the top-level collection associated with PreparsedData.
  • Usage
    [in] Usage of the value.
  • UsageValue
    [out] Pointer to a buffer in which the function returns the value data.
  • PreparsedData
    [in] Pointer to a top-level collection's preparsed data.
  • Report
    [in] Pointer to a report that contains values.
  • ReportLength
    [in] Length, in bytes, of the report located at Report.

Return Values

The following table shows the possible return values.

Value Description
HIDP_STATUS_SUCCESS The function successfully returned the value data.
HIDP_INVALID_REPORT_LENGTH Report length is not valid.
HIDP_INVALID_REPORT_TYPE Specified report type is not valid.
HIDP_STATUS_INCOMPATIBLE_REPORT_ID Report contains a collection with buttons in the specified usage page, but there are no such usages in the report.
HIDP_STATUS_INVALID_PREPARSED_DATA Preparsed data is not valid.
HIDP_STATUS_USAGE_NOT_FOUND Collection does not contain a value in the specified usage page in any report of the specified report type.

Remarks

The terms button and usage are used synonymously.

HidP_GetUsageValue does not sign or scale the value. To extract a signed value, use HidP_GetScaledUsageValue. To manually assign the sign bit, you can determine the position of the sign bit from the information in a value's HIDP_VALUE_CAPS structure.

To extract a usage value array, use HidP_GetUsageValueArray.

Requirements

OS Versions: Windows CE .NET 4.2 and later.
Header: Hidpi.h.
Link Library: Hidparse_lib.lib.

See Also

HidP_GetButtons | HidP_GetButtonsEx | HidP_GetCaps | HidP_GetScaledUsageValue | HidP_GetUsages | HidP_GetUsagesEx | HidP_GetUsageValueArray | HIDP_REPORT_TYPE | HIDP_VALUE_CAPS

Send Feedback on this topic to the authors

Feedback FAQs

© 2006 Microsoft Corporation. All rights reserved.