Partager via


linger (Windows CE 5.0)

Send Feedback

This structure maintains information about a specific socket that specifies how that socket should behave when data is queued to be sent and the closesocket function is called.

struct linger {u_short l_onoff;u_short l_linger;};

Members

  • l_onoff
    Specifies whether a socket should remain open for a specified amount of time after a closesocket function call to enable queued data to be sent.
  • l_linger
    Enabling SO_LINGER also disables SO_DONTLINGER, and vice versa. Note that if SO_DONTLINGER is DISABLED (that is, SO_LINGER is ENABLED) then no time-out value is specified. In this case, the time-out used is implementation dependent. If a previous time-out has been established for a socket (by enabling SO_LINGER), this time-out value should be reinstated by the service provider.

Remarks

To enable SO_LINGER, the application should set l_onoff to a nonzero value, set l_linger to zero or the desired time-out (in seconds), and call the setsockopt (Windows Sockets) function. To specify SO_DONTLINGER (that is, disable SO_LINGER) l_onoff should be set to zero and setsockopt should be called. Note that enabling SO_LINGER with a nonzero timeout on a nonblocking socket is not recommended.

Requirements

OS Versions: Windows CE .NET 4.0 and later.
Header: Winsock2.h.

See Also

setsockopt (Windows Sockets) | getsockopt (Windows Sockets) | closesocket

Send Feedback on this topic to the authors

Feedback FAQs

© 2006 Microsoft Corporation. All rights reserved.