Partager via


BthReadScanEnableMask (Windows Embedded CE 6.0)

1/6/2010

This function reads the adapter's scan mode.

Note

To preserve Win32 compatibility, consider using the Winsock equivalent of this function. To do so, pass SO_BTH_GET_SCAN as the optname value in getsockopt.

Syntax

int BthReadScanEnableMask(
  unsigned char* pmask
);

Parameters

  • pmask
    [in] Pointer to the adapter's scan mode.

    The following table shows the possible scan mode values.

    Value Definition

    0x00

    No scans are enabled.

    0x01

    Inquiry scan is enabled and page scan is disabled.

    0x02

    Inquiry scan is disabled and page scan is enabled.

    0x03

    Inquiry scan is enabled and page scan is enabled.

Return Value

This function returns ERROR_SUCCESS when it completes successfully. A return value of ERROR_SERVICE_NOT_ACTIVE indicates that the hardware is not inserted or that the Bluetooth stack is not present.

Other standard error codes may be returned as appropriate.

Remarks

For more information about this function, see the Read_Scan_Enable part of the Bluetooth Core Specification.

Requirements

Header bt_api.h
Library Btdrt.lib
Windows Embedded CE Windows CE .NET 4.2 and later

See Also

Reference

Bluetooth OS Functions

Other Resources

Bluetooth Application Development