Partager via


Msvm_LastAppliedSettingData class

An association between a virtual system and the setting data of the snapshot which was most recently applied to the virtual system.

The following syntax is simplified Managed Object Format (MOF) code, and it includes all of the inherited properties.

Syntax

[Association, Aggregation, Dynamic, Provider("VmmsWmiInstanceAndMethodProvider"), AMENDMENT]
class Msvm_LastAppliedSettingData : CIM_ElementSettingData
{
  uint16                            IsDefault = 0;
  uint16                            IsCurrent = 0;
  uint16                            IsNext = 0;
  uint16                            IsMaximum = 0;
  uint16                            IsMinimum = 0;
  Msvm_ComputerSystem           REF ManagedElement;
  Msvm_VirtualSystemSettingData REF SettingData;
};

Members

The Msvm_LastAppliedSettingData class has these types of members:

Properties

The Msvm_LastAppliedSettingData class has these properties.

IsCurrent

Data type: uint16

Access type: Read-only

Indicates that the referenced setting is currently being used in the operation of the element or that this information is unknown. This property is inherited from CIM_ElementSettingData. The default value is 0 (Unknown).

Unknown (0)

Is Current (1)

Is Not Current (2)

IsDefault

Data type: uint16

Access type: Read-only

Indicates that the referenced setting is a default setting for the element or that this information is unknown. This property is inherited from CIM_ElementSettingData. The default value is 0 (Unknown).

Unknown (0)

Is Default (1)

Is Not Default (2)

IsMaximum

Data type: uint16

Access type: Read-only

Qualifiers: Experimental

This property affects the interpretation of all non-null, non-enumerated, non-binary, numeric, non-key properties of the associated setting data instance. All other properties of the associated setting data instance are not affected by this property. This property is inherited from CIM_ElementSettingData.

Note

It is assumed that the semantics of each property of this set are designed to be compared mathematically.

Unknown (0)

The affected property values specified in the associated setting data instance may correspond to maximum setting values.

Not Applicable (1)

The affected property values specified in the associated setting data instance shall not be interpreted with respect to whether each defines a maximum.

Is Maximum (2)

The affected property values specified in the associated setting data instance shall define maximum setting values.

Is Not Maximum (3)

The affected property values specified in the associated setting data instance shall not define maximum setting values.

IsMinimum

Data type: uint16

Access type: Read-only

Qualifiers: Experimental

This property affects the interpretation of all non-null, non-enumerated, non-binary, numeric, non-key properties of the associated setting data instance. All other properties of the associated setting data instance are not affected by this property. This property is inherited from CIM_ElementSettingData. The default value is 0 (Unknown).

Note

It is assumed that the semantics of each property of this set are designed to be compared mathematically.

Unknown (0)

The affected property values specified in the associated setting data instance may correspond to minimum setting values.

Not Applicable (1)

The affected property values specified in the associated setting data instance shall not be interpreted with respect to whether each defines a minimum.

Is Minimum (2)

The affected property values specified in the associated setting data instance shall define minimum setting values.

Is Not Minimum (3)

The affected property values specified in the associated setting data instance shall not define minimum setting values.

IsNext

Data type: uint16

Access type: Read-only

Qualifiers: Experimental

Indicates whether the referenced setting is the next setting to be applied. This property is inherited from CIM_ElementSettingData. The default value is 0 (Unknown).

Unknown (0)

Unknown.

Is Next (1)

The setting will be applied to the managed element every time the managed element is reset.

Is Not Next (2)

This setting is no longer used.

Is Next For Single Use (3)

The setting will only be applied to the managed element once, and then this flag will be set to Is Not Next (2).

ManagedElement

Data type: Msvm_ComputerSystem

Access type: Read-only

Qualifiers: Override ("ManagedElement")

A reference to an instance of Msvm_ComputerSystem that represents the computer system that was the target of the application.

SettingData

Data type: Msvm_VirtualSystemSettingData

Access type: Read-only

Qualifiers: Override ("SettingData")

A reference to an instance of Msvm_VirtualSystemSettingData that represents the snapshot setting data that was most recently applied to the computer system.

Remarks

Access to the Msvm_LastAppliedSettingData class might be restricted by UAC Filtering. For more information, see User Account Control and WMI.

Requirements

Minimum supported client
None supported
Minimum supported server
Windows Server 2008
End of client support
None supported
End of server support
Windows Server 2012 R2
Namespace
Root\Virtualization
MOF
WindowsVirtualization.mof

See also

CIM_ElementSettingData

CIM_ElementSettingData

Virtual System Classes