Jaa


_BusinessDataAdmin2::ImportCatalogs Method

For the latest version of Commerce Server 2007 Help, see the Microsoft Web site.

Use this method to import the profile catalog (profile schema) in an XML document to the business data store.

HRESULT _BusinessDataAdmin2::ImportCatalogs(
  BSTR* sXMLDocument
);
Sub ImportCatalogs(
    sXMLDocument As String
)

Parameters

  • sXMLDocument
    [C++]

    [in] A pointer to a BSTR that contains the XML document containing the profile catalog to be imported.

    [Visual Basic]

    A String that contains the XML document containing the profile catalog to be imported.

Return Value

[C++] This method returns an HRESULT indicating whether it completed successfully. See the Error Values section for more details.

[Visual Basic] None.

Error Values

[C++] This method returns S_OK (0x00000000) to indicate success and either standard or custom COM HRESULT error values to indicate failure. For more information about standard COM errors, see Standard COM Errors.

[Visual Basic] This method sets the Number property of the global Err object to S_OK (&H00000000) to indicate success and to either standard or custom COM error values to indicate failure. For more information about standard COM errors, see Standard COM Errors.

The following table shows the custom COM errors that this method can return.

Constant

Value

Description

ERR_NOCONNECTION

0x800A00BF

&H800A00BF

191

No connection is open to the database. The Connect() method should be called first.

ERR_XML_PARSE

0x800A007A

&H800A007A

122

Parse errors in XML document '%0', line %1, col %2. Reason: %3

ERR_BAD_NAMESPACE

0x800A00CB

&H800A00CB

203

The XML does not contain the correct namespace.

ERR_MEMBER_INVALID_NEWDELETE

0x800A00A2

&H800A00A2

162

One or more profile-members have invalid attributes: isNew='1' and isDeleted='1'.

ERR_MISSING_CATALOG

0x800A00CD

&H800A00CD

205

The file does not contain any catalogs.

ERR_MEMBER_INVALID_NEWMODIFIED

0x800A00A4

&H800A00A4

164

One or more profile-members have invalid attributes: isNew='1' and isModified='1'.

ERR_INVALID_CATALOG_NAME

0x800A00CC

&H800A00CC

204

The catalog '%0' is an invalid name.

ERR_CATALOG_DELETEFAILED

0x800A0079

&H800A0079

121

Cannot delete catalog '%0'. Source: '%1' Reason: '%2'

ERR_CATALOG_EXISTS

0x800A006E

&H800A006E

110

Catalog '%0' already exists.

ERR_CATALOG_NOTFOUND

0x800A0074

&H800A0074

116

Cannot find catalog '%0'.

ERR_SOURCE_INVALIDTYPE

0x800A00B0

&H800A00B0

176

'%0' is not a valid source type.

ERR_NO_SRCINFOS

0x800A0087

&H800A0087

135

No source-infos were specified for data-source '%0'.

ERR_TOO_MANY_SRCINFOS

0x800A0088

&H800A0088

136

More than one source-info is specified for non-partitioned data-source '%0'. A non-partitioned data source may only have one source-info.

ERR_NOT_ONE_DEFAULT_SRCINFO

0x800A0089

&H800A0089

137

One source-info must be marked as default for data-source '%0'.

ERR_TOO_MANY_PARTITIONS

0x800A00BA

&H800A00BA

186

The data source '%0' contains %1 partitions. A single data source cannot have more than %2 partitions.

ERR_SOURCE_INVALIDNAME

0x800A00A9

&H800A00A9

169

The data source '%0' cannot be created because the source name contains invalid characters: %1

ERR_DUPLICATE_SOURCENAME

0x800A00BD

&H800A00BD

189

A data-source already exists with the name '%0'.

ERR_SOURCE_EXISTS

0x800A0066

&H800A0066

102

Error: The data-source '%0' already exists and cannot be created or modified.

ERR_DUPLICATE_PARTITIONNAME

0x800A00BE

&H800A00BE

190

A data-source partition already exists with the name '%0'.

ERR_SRCINFO_SRCTYPE

0x800A00B3

&H800A00B3

178

The source type of data-source '%0' cannot be modified.

ERR_SRCINFO_NOTFOUND

0x800A008A

&H800A008A

138

The source-info '%1' could not be found in data-source '%0'.

ERR_ATTRIBUTE_INVALIDNAME

0x800A00A8

&H800A00A8

168

The attribute '%0' cannot be created because the attribute name contains invalid characters: %1

ERR_ATTRIBUTE_EXISTS

0x800A0085

&H800A0085

133

Duplicate names are not allowed: '%0' already exists on '%1'.

ERR_TABLE_INVALIDNAME

0x800A00B1

&H800A00B1

177

The data object '%0' cannot be created because the object name contains invalid characters: %1

ERR_TABLE_EXISTS

0x800A0082

&H800A0082

130

The data-object '%0' already exists. (Source '%1', Catalog '%2'.)

ERR_TABLE_NOTFOUND

0x800A0083

&H800A0083

131

The data-object '%0' could not be found. (Source '%1', Catalog '%2'.)

ERR_COLUMN_EXISTS

0x800A007F

&H800A007F

127

The data-member '%0' already exists.

ERR_COLUMN_NOTFOUND

0x800A007E

&H800A007E

126

The data-member '%0' could not be found.

ERR_INVALID_TYPEDEF

0x800A0078

&H800A0078

120

The data type '%1' for source member '%0' is invalid.

ERR_INVALID_TYPEDEF_FOR_SOURCE

0x800A00B7

&H800A00B7

183

The data type '%1' for source member '%0' is invalid (data type invalid for source type '%2').

ERR_MEMBER_EXISTS

0x800A0077

&H800A0077

119

Profile-member '%1' cannot be created. A property or group named '%0' already exists within the profile.

ERR_MEMBER_NOTFOUND

0x800A0081

&H800A0081

129

The profile-member '%0' could not be found.

ERR_MEMBER_NOT_GROUP

0x800A007D

&H800A007D

125

The profile-member corresponding to group '%0' in the XML document is not a group.

ERR_PRIMARYKEY

0x800A00AB

&H800A00AB

171

Profile '%0' could not be created/updated because it does not have exactly one primary key defined.

ERR_JOINKEY

0x800A00AC

&H800A00AC

172

Profile '%0' could not be created/updated because it does not have exactly one join key defined.

ERR_INVALIDTYPE_RDNATTR

0x800A00AD

&H800A00AD

173

The profile-property '%0' is marked as an RDN-attribute, but is not of type 'STRING'.

ERR_INVALID_HASHKEY

0x800A00AE

&H800A00AE

174

The profile-property '%0' is marked as a hashing key, but is not of type 'STRING'.

ERR_INVALID_UNIQUEKEY

0x800A00AF

&H800A00AF

175

The profile-property '%0' is marked as a unique, primary, and/or join key, but is not of type 'STRING' or 'NUMBER'.

ERR_INVALIDMAP

0x800A00B3

&H800A00B3

179

The profile property '%0' is mapped to a data member in a source which is not referenced by the join key.

ERR_DUPLICATEJOINMAP

0x800A00B4

&H800A00B4

180

The join key '%0' references more than one data member from a single source. A join key may map to only one member from a data object.

ERR_KEY_MULTIVALUE

0x800A00BB

&H800A00BB

187

The property '%0' cannot be multi-valued because it is a key.

ERR_OLEDB_MULTIVAL

0x800A00BC

&H800A00BC

188

The property '%0' cannot be marked as multi-valued. It references a data member from an OLEDB-ANSI source of type '%1'. Only members of type 'STRING' may be marked as multi-valued.

ERR_VALUE_TOO_LONG

0x800A00B8

&H800A00B8

184

The database field '%0' cannot be updated. The value '%1' exceeds the maximum length of %2 characters.

ERR_CACHEDPROP_IS_PRIMARYKEY

0x800A00B5

&H800A00B5

181

The primary key for this profile may not be a cached (non-persistent) property.

ERR_CACHEDPROP_IS_JOINKEY

0x800A00B6

&H800A00B6

182

The join key for this profile may not be a cached (non-persistent) property.

ERR_MULTIPLE_RDNATTRS

0x800A008D

&H800A008D

141

The profile '%0' contains multiple properties marked as the RDN Attribute for the data source '%1'. Exactly one RDN Attribute must be defined for each LDAPv3-compliant data source.

ERR_MULTIPLE_HASHKEYS

0x800A008E

&H800A008E

142

The profile '%0' contains multiple properties marked as the hashing key.

ERR_INVALID_RDNATTR

0x800A008F

&H800A008F

143

The profile-property '%0' is marked as an RDN-attribute, but does not map to an LDAPv3-compliant data-source.

ERR_PROP_INVALID_HASHKEY

0x800A0090

&H800A0090

144

The profile-property '%0' is marked as a hashing-key, but does not map to any partitioned data-sources.

ERR_NO_RDN_ATTRIBUTE

0x800A0091

&H800A0091

145

The profile '%0' uses an LDAPv3-compliant data-source, but no property is marked as the RDN-attribute. Exactly one RDN Attribute must be defined for each LDAPv3-compliant data source.

ERR_INVALID_DATATYPE

0x800A00C0

&H800A00C0

192

The property: [%0] in profile: [%1] is mapped to an incorrect data type.

ERR_INVALID_MARKEDTYPEREF

0x800A00C1

&H800A00C1

193

The property: [%0] in profile: [%1] is incorrectly marked as a reference type.

ERR_INVALID_MULTI

0x800A00C2

&H800A00C2

194

The property: [%0] in profile: [%1] is incorrectly marked as multivalued.

ERR_INVALID_TYPEREF

0x800A00C3

&H800A00C3

195

The property: [%0] in profile: [%1] is referencing an invalid type.

ERR_INVALID_PROPTYPE

0x800A00C4

&H800A00C4

196

The property: [%0] in profile: [%1] is of incorrect type.

ERR_INVALID_MAPPEDDATA

0x800A00C5

&H800A00C5

197

The property: [%0] in profile: [%1] is mapped to a data member: [%2] but this data member does not exist.

ERR_INVALID_MAPPEDDATATYPE

0x800A00C6

&H800A00C6

198

The property: [%0] in profile: [%1] is mapped to data member: [%2] of incorrect type

ERR_INVALID_PROFILEREF

0x800A00C7

&H800A00C7

199

The property: [%0] in profile: [%1] is referencing a profile: [%2] that does not exist.

ERR_INVALID_SITETERMREF

0x800A00C8

&H800A00C8

200

The property: [%0] in profile: [%1] is referencing a siteterm: [%2] that does not exist.

Remarks

You must call the __BusinessDataAdmin2::Connect Method before calling this method.

The XML data in the parameter sXMLDocument must contain a single profile catalog, and it must conform to the schema in the file MSCSProfileSchema.xml.

If the catalog you want to import was exported without credentials you will need to add credentials for each data source in the catalog before it can be imported.

Example

The following example imports a catalog from the file ProfileCatalog.xml:

Dim xd As New XmlDocument()
xd.Load("C:\myFolder\ProfileCatalog.xml")
Dim sXml As String = xd.OuterXml
BusinessDataAdmin2.ImportCatalogs(sXml)

See Also

Other Resources

BusinessDataAdmin2 Object