Muokkaa

Jaa


How to Configure the BizTalk Framework Disassembler Pipeline Component

The BizTalk Framework Disassembler pipeline component should be used in the Disassemble stage of a receive pipeline.

To configure the properties for the BizTalk Framework Disassembler pipeline component

  1. Drag the BizTalk Framework Disassembler pipeline component into the Disassemble stage of a receive pipeline.

  2. In the Properties window, in the Pipeline Component Properties section, do the following.

    Use this To do this
    Allow unrecognized message Indicates whether to allow messages that do not have a recognized schema to be passed through the disassembler.

    Default value: False
    Document schemas Indicates the namespace and typename of the schema or schemas to be applied to the document. For more information, see How to Use the Schema Collection Property Editor.

    Schemas specified in this property should have unique target namespaces. If any of the schemas have the same namespace, the validation of the document instances may not work as expected. If schemas must have the same namespace, you should either create a separate pipeline for each schema and specify one schema per BizTalk Framework Disassembler pipeline component or use one pipeline but do not specify any schemas as parameters for the BizTalk Framework Disassembler pipeline component.

    Default value: Empty collection
    Envelope schemas Indicates the namespace and typename of the schema or schemas to be applied to the envelope. For more information, see How to Use the Schema Collection Property Editor.

    Schemas specified in this property should have unique target namespaces. If any of the schemas have the same namespace, the validation of the document instances may not work as expected. If schemas must have the same namespace, you should either create a separate pipeline for each schema and specify one schema per BizTalk Framework Disassembler pipeline component or use one pipeline but do not specify any schemas as parameters for the BizTalk Framework Disassembler pipeline component.

    Default value: Empty collection
    Validate document structure When True, performs a validation of the incoming message to the disassembler, including the envelopes. Note: When True, you may receive a "Two or more of the selected schema share the same target namespace" error if you specify two or more schemas for the Document schemas or Envelope schemas properties.

    Default value: False

See Also

BizTalk Framework Disassembler Pipeline Component
Configuring Native Pipeline Components
Pipelines-AssemblerDisassembler (BizTalk Server Samples Folder)
Configuring Native Pipeline Components