Addresses other issues related to Microsoft BizTalk Accelerator for HL7 (BTAHL7).

Message rejected by the BTAHL7 engine

Symptom

Messages are randomly rejected by the message engine.

Possible Cause : According to the HL7 standard, enumeration values for table 0338 contains the "L&I" value. Field 6 of the PRA segment may contain this value. Since BTAHL7 treats the "&" character as a delimiter, the message is rejected.

Resolution : There are three potential resolutions for this issue:

  1. In the message instance, handle the "&" character through an escape sequence, such as using the character combination L\T\I.

  2. Add an enumeration value of "LI" at PRA 6 in the schema and use this value instead in the message instance.

  3. Use a completely different subcomponent separator in MSH2; however, this particular solution may not be practical depending upon your environment.

Cannot edit the HL7 schema using Visual Studio

Symptom

Cannot edit the HL7 schema using Microsoft Visual Studio.

Possible Cause : Visual Studio does not support some HL7 schemas.

Resolution : Use other editors, such as Microsoft Notepad, to edit HL7 schemas.

Message handling fails with no errors logged

Symptom

The system processes messages without logging error messages or placing messages in the suspended message queue.

Possible Cause : The HeaderSpecType and DocumentSpecType property values are case-sensitive. When you deploy your pipelines, a typographical error in these names can cause messages to be mishandled and dropped with no errors logged.

Resolution : Observe case-sensitivity when using the HeaderSpecType and DocumentSpecType property value names.

Message header fields are not validated correctly

Symptom

Validation of a header field failed.

Reason: The BTAHL7 serializer validated a promoted property, not the actual header-field context property.

Possible Cause : A change occurred to the promoted property corresponding to the header through an orchestration or a map.

Resolution : The context properties of message headers MSH1, MSH2, and MSH5{1-3} need to be updated so that they are in synchronization with the data.

The MLLP adapter is not removed during uninstall

Symptom

The BTAHL7 setup program did not remove the MLLP adapter during uninstallation of BTAHL7.

Possible Cause : There was a receive location or send port with a transport type of MLLP. BTAHL7 setup cannot remove the MLLP adapter if it is being referenced in any of the BizTalk Server projects.

Resolution : After uninstallation of BTAHL7 has completed, do the following:

  1. In the BizTalk Server Administration Console, remove all receive locations and send ports that have a transport type of MLLP, or change the transport type of the receive locations or send ports to another type.

  2. In the Administration Console, delete the MLLP adapter.

  3. Restart the host instance.

BTAHL7 cannot be uninstalled if BizTalk Server has already been uninstalled

Symptom

Uninstalling BTAHL7 results in the following error:

A network error while attempting to read from file C:\Windows\Installer\Microsoft BizTalk <version\> Accelerator for HL7.msi

Possible Cause : BizTalk Server was uninstalled before uninstallation of BTAHL7 was attempted. You must uninstall BTAHL7 before uninstalling BizTalk Server.

Resolution : Reinstall BizTalk Server, then uninstall BTAHL7, and then uninstall BizTalk Server.

Messages are still sent after the applicable MLLP send port has been stopped

Symptom

After you stop an MLLP send port, the messages that are sent through that send port do not stop, but continue to be sent.

Possible Cause : When you stop a send port, the connection remains established until it is removed by stopping the BizTalk host. As a result, messages are still sent after the send port has been stopped. This occurs because Biztalk Server does not call into the MLLP adapter during start or stop of the send port. BizTalk Server calls into the MLLP adapter only during the start and stop of the host service.

Resolution : You can remove the connection and stop transmission of messages by stopping the host instance that is the send handler for the send port that you stopped. However, stopping that host instance might affect other messages that you do not want to stop. If you know that this is the case, you should configure the send port differently when you create it. You should create another host instance to serve as the send handler for only this MLLP send port (or a subset of your send ports). You can then stop transmission of messages from this send port by stopping this host instance. This will then not affect transmission of other messages on other send ports that use other send handlers.